HOFFMANN 4922-2-020Recalls & reported problems
Stryker GmbH · 5 Hole Pin Clamp Dia 4,5,6mm · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04546540681010), received between Sep 10, 2018 and Aug 8, 2024 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Loose or Intermittent Connection” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Loose or Intermittent Connection2
- Adverse Event Without Identified Device or Use Problem1
- Device Difficult to Setup or Prepare1
- Device Slipped1
Patient problems
- Implant Pain1
- No Consequences Or Impact To Patient1
- No Information1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryAug 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PRESENT SWISS TRAUMA FRACTURE REGISTRY (SWTR) IS A PROSPECTIVE, MULTI-CENTER, OBSERVATIONAL STUDY TO COLLECT DATA ON ALL STRYKER TRAUMA AND EXTREMITIES PRODUCTS WITH THE AIM TO ADD TO THE EXISTING CLINICAL EVIDENCE TO SUPPORT THE SAFETY AND PERFORMANCE OF STRYKER IMPLANTS FOR THE APPROVED INDICATIONS FOR USE. THE SWTR CAPTURES DATA EVALUATING THE REAL-WORLD USAGE OF STRYKER IMPLANTS AT TRAUMA CENTERS WITH THE CAPACITY, TRAINING, AND EXPERIENCE TO GATHER CLINICALLY RELEVANT STANDARD OF CARE SAFETY AND PERFORMANCE ENDPOINT DATA. DURING THE REVIEW OF THE REPORT, PERSISTENT PAIN WAS NOTED FOR THIS PATIENT DURING THE FOLLOW-UP VISIT.
Patient problems: Implant Pain
MAUDE report 19938324 ↗MalfunctionFeb 18, 2020Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
THE ATTACHMENTS COULD NOT BE ATTACHED. REPLACEMENT DEVICES WERE AVAILABLE. ADDITIONALLY REPORTED: THE ATTACHMENT COULD NOT BE PUT INTO THE 5-HOLE PIN HOLDER. THE APPROACHES DID NOT FIT INTO THE "STAR BORE" PROVIDED FOR THEM. THE ORIGINAL H3 7MM T-WRENCHES TO LOOSEN THE SCREWS DURING TESTING WERE USED. THE CUSTOMER NOTICED THE PROBLEMS ALREADY WHEN CONNECTING THE PIN HOLDER WITH THE ATTACHMENTS, SO NO FURTHER ASSEMBLY WAS MADE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9721595 ↗MalfunctionSep 10, 2018Loose or Intermittent Connection; Device Slipped
THE HOFFMANN 3 KICKSTAND FOR AN ANKLE DELTA DFAME CONTINUES TO LOOSEN AND SLIDE OUT. DELTA COUPLINGS WE¿RE FULLY TIGHTENED AND HAS HAPPENED BEFORE PER THE SURGEON (NEVER NOTIFIED OF PRIOR ISSUE) WHEN CONNECTING THE KICKSTAND TO THE TRANSFIXING PIN OR TO THE 11X 350MM CONNECTING RODS. HE FEELS AS IF THE COUPLINGS WERE TIGHT AS POSSIBLE WITH BOTH THE T HANDLE AND WRENCH. ISSUE WAS NOTICED POST SURGERY WHEN THE STABILITY OF THE FRAME DID NOT REMAIN INTACT 2 DAYS POST SURGERY
Patient problems: No Information
MAUDE report 7861891 ↗MalfunctionSep 10, 2018Loose or Intermittent Connection
THE HOFFMANN 3 KICKSTAND FOR AN ANKLE DELTA DFAME CONTINUES TO LOOSEN AND SLIDE OUT. DELTA COUPLINGS WE¿RE FULLY TIGHTENED AND HAS HAPPENED BEFORE PER THE SURGEON (NEVER NOTIFIED OF PRIOR ISSUE) WHEN CONNECTING THE KICKSTAND TO THE TRANSFIXING PIN OR TO THE 11X 350MM CONNECTING RODS. HE FEELS AS IF THE COUPLINGS WERE TIGHT AS POSSIBLE WITH BOTH THE T HANDLE AND WRENCH. ISSUE WAS NOTICED POST SURGERY WHEN THE STABILITY OF THE FRAME DID NOT REMAIN INTACT 2 DAYS POST SURGERY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7861836 ↗
Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT devices
- PRECICE® Plating System LP4.5-DLF31Nuvasive Specialized Orthopedics, Inc. · Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component3 recalls0 reports
- R3 71364451Smith & Nephew, Inc. · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT145 reports
- DFS HA BONE SCREWS HAA60-15040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15050Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAB60-12040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-13040Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-18030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
- DFS HA BONE SCREWS HAA60-15030Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page