Wingspan M003WS0400150Recalls & reported problems
Stryker Corporation · Stent System · Class f · Implant
All models of Wingspan (12)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540722867), received between Feb 22, 2017 and Aug 13, 2018 — classified as 1 death, 1 malfunction.
The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Activation, Positioning or Separation Problem1
- Break1
Patient problems
- Coma1
- Death1
- No Patient Involvement1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 13, 2018Break; Break
IT WAS REPORTED THAT DURING PREPARATION FOR THE PROCEDURE, THE STENT DELIVERY WIRE BROKE. THERE WERE NO REPORTED CLINICAL CONSEQUENCES TO THE PATIENT.
Patient problems: No Patient Involvement
MAUDE report 7779199 ↗DeathFeb 22, 2017Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem
IT WAS REPORTED THAT A PATIENT WAS PRESENTED IN A LIFE-THREATENING CONDITION WITH A BASILAR THROMBOTIC STROKE AND NEUROLOGICAL DEFICIT. ACCESS TO THE CLOT WAS LIMITED TO THE RIGHT VERTEBRAL ARTERY (VA) THAT PRESENTED A CRITICAL STENOSIS OF THE VA-DISTAL V4 SEGMENT. LEFT VERTEBRAL ARTERY WAS OCCLUDED AND NOT ACCESSIBLE. ANGIOPLASTY WITH A BALLOON CATHETER OF THE STENOSIS OF VA-V4 SEGMENT LED TO DISSECTION RESULTANT IN HEMATOMA AND OCCLUSION. MEDICAL INTERVENTION IN ORDER TO RESTORE BLOOD FLOW THROUGH THE OCCLUDED VA- V4 SEGMENT BY ANGIOPLASTY WAS PERFORMED WITHOUT SUCCESS. THEN, STENTING OF THE VA-V4 SEGMENT WITH A FIRST STENT WAS PERFORMED. HOWEVER, THE DISTAL STENT TINES DID NOT OPEN PROPERLY EVEN WITH ADDITIONAL ANGIOPLASTY PROCEDURE. BLOOD FLOW WAS NOT RESTORED. A SECOND STENT WAS ATTEMPTED TO BE IMPLANTED BUT COULD NOT BE DEPLOYED BEYOND THE POORLY OPENED DISTAL TINES OF THE FIRST DEPLOYED STENT. A THIRD STENT (SUBJECT DEVICE) WAS DEPLOYED MORE DISTALLY IN THE BASILAR ARTERY AND OVERLAPPING THE ORIGINAL STENT. THE STENT WAS ONLY PLACED WITH GREAT DIFFICULTY THROUGH THE FIRST STENT. THERE WAS SOME BENDING OF THE HYPOTUBE BUT IT DID NOT RENDER THE STENT UNUSABLE. BLOOD FLOW WAS N
Patient problems: Coma; Death
MAUDE report 6351667 ↗
Other intracranial neurovascular stent devices
- CERENOVUS ENTERPRISE ENF402312Medos International Sàrl · intracranial neurovascular stent1 death90 reports
- PulseRider Aneurysm Neck Reconstruction Device 201-DMedos International Sàrl · Intracranial Neurovascular Stent2 deaths74 reports
- CERENOVUS ENTERPRISE ENF402300Medos International Sàrl · intracranial neurovascular stent2 deaths66 reports
- CERENOVUS ENTERPRISE ENF403012Medos International Sàrl · intracranial neurovascular stent1 death42 reports
- CERENOVUS ENTERPRISE ENF452212Medos International Sàrl · intracranial neurovascular stent41 reports
- CERENOVUS ENTERPRISE ENF401600Medos International Sàrl · intracranial neurovascular stent36 reports
- CERENOVUS ENTERPRISE ENF401612Medos International Sàrl · intracranial neurovascular stent36 reports
- CERENOVUS ENTERPRISE ENF452812Medos International Sàrl · intracranial neurovascular stent31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page