NA 0400655000Recalls & reported problems
Stryker Corporation · T4 Eight Station Battery Charger 120V~ 50-60Hz 1.7A · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04546540903839), received between Jul 2, 2018 and Feb 4, 2020 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Overheating of Device” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Overheating of Device3
Patient problems
- No Consequences Or Impact To Patient2
- No Patient Involvement2
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 4, 2020Overheating of Device; Overheating of Device
IT WAS REPORTED THAT AT THE USER FACILITY, THE DEVICE WAS OVERHEATING. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; THERE WERE NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION.
Patient problems: No Patient Involvement
MAUDE report 9667909 ↗MalfunctionSep 18, 2018Overheating of Device; Overheating of Device
THE USER FACILITY REPORTED THAT THE DEVICE OVERHEATED DURING SET UP. THERE WERE NO REPORTED ADVERSE CONSEQUENCES; THERE WERE NO PROCEDURE DELAYS; THERE WAS NO MEDICAL INTERVENTION REQUIRED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Consequences Or Impact To Patient; No Patient Involvement
MAUDE report 7885681 ↗MalfunctionJul 2, 2018Overheating of Device; Overheating of Device
THE USER FACILITY REPORTED THAT THE DEVICE OVERHEATED DURING TESTING. THERE WERE NO REPORTED ADVERSE CONSEQUENCES; THERE WERE NO PROCEDURE DELAYS; THERE WAS NO MEDICAL INTERVENTION REQUIRED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7654565 ↗
FDA clearance and classification
The FDA regulates product code FXZ (helmet, surgical) under 21 CFR 878.4040 as a Class I device. 21 CFR 878.4040 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the NA 0400655000
Has the NA 0400655000 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04546540903839), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the NA 0400655000?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Jul 2, 2018 and Feb 4, 2020. In those reports, the most common specific device problem is “Overheating of Device” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the NA 0400655000?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the NA 0400655000 FDA approved?
Devices of this type (product code FXZ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Stryker Corporation.
Who makes the NA 0400655000, and is it still sold?
The FDA's device database lists Stryker Corporation as the company responsible for it (brand NA, model 0400655000). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other HELMET, SURGICAL devices
- NA 0408660000Stryker Corporation · HELMET, SURGICAL9 reports
- Flyte 0408600000Stryker Corporation · HELMET, SURGICAL4 reports
- Flyte 0408645000Stryker Corporation · HELMET, SURGICAL4 reports
- Flyte 0408655000Stryker Corporation · HELMET, SURGICAL2 reports
- NA 0400650000Stryker Corporation · HELMET, SURGICAL1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page