Skip to content

CROSSWALK PSC18150ARecalls & reported problems

Asahi Intecc CO., Ltd. · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04547327133524), received between Aug 7, 2025 and Aug 7, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Device Dislodged or Dislocated1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 7, 2025Break; Device Dislodged or Dislocated

    LOWER EXTREMITY ANGIOGRAM ON PATIENT WITH KNOWN DISEASE (HIGHLY CALCIFIED) OSTEOMYELITIS OF RIGHT GREAT TOE-ATTEMPT FOR REVASCULARIZATION. CROSSWALK SUPPORT CATHETER TIP BROKE OFF IN THE CALCIUM OF RIGHT TIBIAL ARTERY. DURING PERIPHERAL INTERVENTION DISTAL END OF PLASTIC CATHETER BECAME DISLODGED FROM CATHETER SHEATH. TIP OF DEVICE IMBEDDED IN CALCIUM IN VESSEL, UNABLE TO SNARE OR REMOVE. PHYSICIAN DEEMED IT SAFE, DUE TO LOCATION TO LEAVE IMBEDDED IN VESSEL.

    Patient problems: Foreign Body In Patient

    MAUDE report 22737028 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →