iSert Intraocular Lens 230 (clear), +29.00DRecalls & reported problems

Hoya Medical Singapore Pte. Ltd. · Class 3 · Implant

All models of iSert Intraocular Lens (69)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04547480301495), received between Aug 6, 2018 and Aug 6, 2018 — classified as 1 injury.

The most frequently reported specific device problem is “Optical Decentration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Optical Decentration1

Patient problems

  • Visual Disturbances1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 6, 2018Optical Decentration; Optical Decentration

    PER THE DATA COLLECTION FORM: ORIGINAL MULTIFOCAL IMPLANTATION [FROM A DIFFERENT MANUFACTURER] CREATED SIGNIFICANT GLARE AND HALOS; ORIGINAL SURGERY DATE OS, (B)(6) 2016. IOL EXCHANGE MONOFOCAL [FROM THIS MANUFACTURER] FOR MULTIFOCAL - DATE OF SURGERY (B)(6) 2017. DATE OF ONSET/PROBLEM: (B)(6) 2017. PROBLEM/EVENT: LENS EXCHANGE MULTIFOCAL FOR MONOFOCAL OS; LENS PLACED IN SULCUS OS; MODERATE BUT STABLE INFERIOR CENTRATION, OPTIC STILL WITHIN UNDILATED PUPIL CAUSING SYMPTOMS OF INTERMITTENT MONOCULAR DIPLOPIA. INFERIOR DECENTRATION OS, NOTED (B)(6) 2017. SECONDARY SURGICAL INTERVENTION IS PENDING IOL EXCHANGE OS FOR ANOTHER MONOFOCAL IN SULCUS. SURGEON IN PROCESS OF RESEARCHING MONOFOCAL SULCUS LENS OPTIONS FOR 2ND MONOFOCAL EXCHANGE PROCEDURE - TBD. IN THE SURGEON'S OPINION, THE LIKELY CAUSE OF THE EVENT: CHANGES TO THE INTEGRITY OF THE SULCUS AND CAPSULE RELATED TO IMPLANTATION THEN SUBSEQUENT EXCHANGE OF ORIGINAL MULTIFOCAL IOL OS. PATIENT'S PROGNOSIS & TREATMENT: GOOD PROGNOSIS. TBD WHICH MONOFOCAL MODEL TO BE USED IN SECOND LENS EXCHANGE OS.

    Patient problems: Visual Disturbances

    MAUDE report 7754285 ↗