iSert Intraocular Lens 250 (clear), +17.50DRecalls & reported problems

Hoya Medical Singapore Pte. Ltd. · Class 3 · Implant

All models of iSert Intraocular Lens (69)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04547480480732), received between Jul 28, 2017 and Dec 11, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Material Split, Cut or Torn” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Split, Cut or Torn3
  • Appropriate Device Problem Term/Code Not Available1

Patient problems

  • Failure of Implant3
  • No Information1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 11, 2025Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN CHINA. DAMAGED HAPTIC AFTER IMPLANTATION. THE PATIENT UNDERWENT RIGHT EYE VITRECTOMY WITH DISLOCATED INTRAOCULAR LENS (IOL) REMOVAL AND SECONDARY IOL IMPLANTATION WITH SCLERAL FIXATION (USING A PRELOADED ASPHERIC POSTERIOR CHAMBER IOL) ON (B)(6) 2025, AT 15:00. THE PROCEDURE WAS PERFORMED WITHOUT SURGICAL CONTRAINDICATIONS AND COMPLETED SUCCESSFULLY. POSTOPERATIVE DAY 1 EXAMINATION REVEALED NO IOL ABNORMALITIES. HOWEVER, ON POSTOPERATIVE DAY 2, IOL DISPLACEMENT WAS OBSERVED, AND MYDRIATIC EXAMINATION IDENTIFIED A NASAL HAPTIC FRACTURE. CONSEQUENTLY, A RIGHT EYE IOL EXPLANTED AND REPLACED ANOTHER IOL WITH SCLERAL FIXATION WAS PERFORMED ON (B)(6) 2025. IOL WAS EXPLANTED ON (B)(6) 2025. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 23785898 ↗
  • InjuryFeb 6, 2025Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN CHINA. DAMAGED HAPTIC AFTER IMPLANTATION. ROOT; DAMAGED HAPTIC. PATIENT HEALTH NOT IMPACTED. IOL WAS EXPLANTED ON (B)(6) 2024. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 21329275 ↗
  • InjuryNov 27, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN MALAYSIA. DAMAGED HAPTIC AFTER IMPLANTATION. TRAILING; MIDDLE; DAMAGED HAPTIC. INCREASED INCISION SIZE. PRODUCT REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY. PATIENT HEALTH NOT IMPACTED. IOL WAS EXPLANTED ON (B)(6) 2024. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 20790314 ↗
  • InjuryJul 28, 2017Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT A LENS HAS BEEN EXPLANTED. ADDITIONAL INFORMATION HAS BEEN REQUESTED BUT HAS NOT YET BEEN RECEIVED.

    Patient problems: No Information

    MAUDE report 6751140 ↗