iSert Intraocular Lens 250 (clear), +19.50DRecalls & reported problems

Hoya Medical Singapore Pte. Ltd. · Class 3 · Implant

All models of iSert Intraocular Lens (69)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 04547480480770), received between Jul 28, 2017 and Jan 20, 2026 — classified as 10 injuries, 1 malfunction.

The most frequently reported specific device problem is “Material Split, Cut or Torn” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Split, Cut or Torn5
  • Break3
  • Adverse Event Without Identified Device or Use Problem1
  • Malposition of Device1
  • Material Rupture1
  • Scratched Material1

Patient problems

  • Failure of Implant6
  • No Known Impact Or Consequence To Patient3
  • Capsular Bag Tear1
  • No Code Available1
  • No Information1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 20, 2026Material Split, Cut or Torn

    EVENT OCCURRED IN CHINA. DAMAGED HAPTIC AFTER IMPLANTATION. THE CAUSE WAS THAT AN INSUFFICIENT AMOUNT OF VISCOELASTIC WAS INJECTED DURING SURGERY, WHICH RESULTED IN THE HAPTIC BEING CLAMPED BEFORE THE LENS IMPLANTATION. THE SURGEON THEN FORCIBLY PUSHED THE LENS FORWARD, CAUSING THE INJECTOR TIP TO FRACTURE. AFTER DISCOVERING THE BROKEN HAPTIC, THE SURGEON REMOVED THE LENS AND IMPLANTED A NEW ONE. CURRENTLY, THE PATIENT HAS NOT EXPERIENCED ANY ADVERSE CONDITIONS POSTOPERATIVELY. PRODUCT REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY; PATIENT HEALTH NOT IMPACTED; IOL WAS EXPLANTED ON (B)(6) 2025. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 24126035 ↗
  • InjuryDec 27, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN MALAYSIA. DAMAGED HAPTIC AFTER IMPLANTATION. TRAILING; MIDDLE. CORNEAL EDEMA. INCREASED INCISION SIZE. PRODUCT REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY. PATIENT HEALTH NOT IMPACTED. NO PERMANENT OR NEGATIVE IMPACT ON PATIENT HEALTH EXPECTED. IOL WAS EXPLANTED ON (B)(6) 2024. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 21031299 ↗
  • InjuryDec 27, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN MALAYSIA. DAMAGED HAPTIC AFTER IMPLANTATION. TRAILING; MIDDLE. INCREASED INCISION SIZE. PRODUCT REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY. PATIENT HEALTH NOT IMPACTED. IOL WAS EXPLANTED ON (B)(6) 2024. PROBLEM CODE: A0414 - MATERIAL SPLIT, CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 21029356 ↗
  • InjuryApr 25, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN CHINA. DAMAGED HAPTIC AFTER IMPLANTATION. MIDDLE; DAMAGED HAPTIC. PATIENT HAS RECOVERED AND IS FINE. IOL WAS EXPLANTED ON (B)(6) 2023. PROBLEM CODE: A0414, MATERIAL SPLIT CUT OR TORN.

    Patient problems: Failure of Implant

    MAUDE report 19188462 ↗
  • InjuryJan 17, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    EVENT OCCURRED IN MALAYSIA DAMAGED HAPTIC AFTER IMPLANTATION IMDRF CODE: A0414, MATERIAL SPLIT CUT OR TORN INCREASED INCISION SIZE; PRODUCT REPLACED WITH ANOTHER LENSIMMEDIATELY DURING SURGERY; PATIENT HEALTH NOT IMPACTED; PATIENT HAS RECOVERED AND IS FINE; NO PERMANENT OR NEGATIVE IMPACT ON PATIENT HEALTH EXPECTED IOL WAS EXPLANTED ON (B)(6) 2023.

    Patient problems: Failure of Implant

    MAUDE report 18530130 ↗
  • InjuryNov 16, 2023Scratched Material; Scratched Material

    EVENT OCCURRED IN CHINA. DAMAGED OPTIC AFTER IMPLANTATION. IMDRF CODE: (B)(6), SCRATCH MATERIAL. PRODUCT REPLACED WITH ANOTHER LENS IMMEDIATELY DURING SURGERY. IOL WAS EXPLANTED ON (B)(6) 2023.

    Patient problems: Failure of Implant

    MAUDE report 18156808 ↗
  • InjuryJun 11, 2019Break; Break

    AFTER THE LENS WAS INSERTED INTO THE PATIENTS EYE, THE SURGEON NOTICED A CHUP IN THE OPTIC. ONE OF OUR DISTRIBUTOR'S REPRESENTATIVES WAS PRESENT FOR THE OPERATION, SO PROPER LUBRICATION WAS USED. THE LENS HAD TO BE CUT FROM THE PATIENTS EYE AND REPLACED WITH ANOTHER LENS. THE PLUNGER TIP LOOKS DAMAGED. PHOTOGRAPHS PROVIDED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8689709 ↗
  • MalfunctionJun 11, 2019Break; Break

    TIP OF THE TRAINING HAPTIC TORE OFF IOL AND WAS LEFT IN THE INJECTOR. IOL WAS ALREADY ADVANCED AND INJECTED. IOL WAS STABLE AND SURGEON WAS HAPPY TO LEAVE IMPLANTED. WILL FOLLOW UP AS ROUTINE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8689673 ↗
  • InjuryMay 10, 2019Break; Break

    THE LENS WAS IMPLANTED ROUTINELY, IT WAS THEN NOTICED BY THE SURGEON THAT THE TRAILING HAPTIC HAD NOT COME OUT OF THE INJECTOR AND HAD BEEN RIPPED AWAY FROM THE OPTIC. THE LENS THEN HAD TO BE CUT IN HALF WHICH HAD THE POTENTIAL TO CAUSE DAMAGED TO THE INTERNAL STRUCTURE. LENS REMOVAL CAUSING ENDOTHELIAL CELL LOSS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8600996 ↗
  • InjurySep 22, 2017Material Rupture; Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE SURGEON RUPTURED THE POSTERIOR CAPSULE DURING LENS MANIPULATION IN THE LEFT EYE. LENS HAD TO BE REMOVED AND REPLACED WITH ANOTHER MODEL LENS. VITRECTOMY WAS PERFORMED.

    Patient problems: Capsular Bag Tear; No Code Available

    MAUDE report 6887425 ↗
  • InjuryJul 28, 2017Malposition of Device

    THE CONSUMER REPORTED HAVING CATARACT SURGERY, AND THE AFTERNOON AFTER THE SURGERY THE SURGEON LOOKED AT THIS EYE AND REPORTEDLY SAID THE LENS IS NOT POSITIONED PROPERLY. THE CONSUMER WAS REFERRED TO ANOTHER DOCTOR TO HAVE THE LENS REPOSITIONED. ADDITIONAL INFORMATION HAS BEEN REQUESTED, BUT NO ADDITIONAL INFORMATION HAS BEEN RECEIVED.

    Patient problems: No Information

    MAUDE report 6752566 ↗

Other Intraocular Lens devices

All Intraocular Lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page