Forceps/Irrigation Plug (Isolated Type) MAJ-891Recalls & reported problems

Olympus Medical Systems Corp. · "MAJ-891 FORCEPS/IRRIGATION PLUG ISOLATED" · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Olympus forceps/irrigation plug is used with endoscopes. Its 257 reports mostly describe cleaning and reprocessing problems, contamination, and parts breaking or coming loose. There was 1 death and 159 injuries, and the reports mention urinary tract infections, fever and sepsis. One recall, open since December 2024, concerns possible leftover material inside the device when it is not fully taken apart for cleaning.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
257
Deaths reported
1
Injuries reported
159
Recalls naming it
1

Summary

The FDA's MAUDE database contains 257 adverse event reports that list this exact device (DI 04953170063114), received between Dec 15, 2020 and Jul 14, 2025 — classified as 1 death, 159 injuries, 97 malfunctions.

The most frequently reported specific device problem is “Device Reprocessing Problem” (86 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 6 reportsDec 2023: 51 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 79 reportsApr 2024: 4 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 2 reportsOct 2024: 13 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 8 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202679
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 18, 2024Open, Classified

    Potential for inadvertent retention of biomaterial when the reprocessing procedure is not performed as instructed, so as not completely removing and disassembling the device.

    Z-0905-2025 · Root cause: Labeling design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Device Reprocessing Problem86
  • Failure to Clean Adequately65
  • Microbial Contamination of Device57
  • Break39
  • Contamination22
  • Detachment of Device or Device Component12
  • Contamination /Decontamination Problem8
  • Melted7

Patient problems

  • Urinary Tract Infection122
  • No Clinical Signs, Symptoms or Conditions96
  • Fever36
  • Unspecified Infection25
  • Pain14
  • Sepsis12
  • Urinary Frequency / Polyuria8
  • Bacterial Infection7

Recent adverse event reports

The 25 most recent of 257 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 14, 2025Device Reprocessing Problem; Device Reprocessing Problem

    CORRECTION TO B5 FOR INFORMATION INADVERTENTLY LEFT OUT OF PREVIOUS REPORT: IT WAS REPORTED BY THE ENDOSCOPIC SUPPORT SPECIALIST (ESS) THAT THE CUSTOMER DISASSEMBLED THE FORCEPS IRRIGATION PLUG INTO THREE PARTS INSTEAD OF FOUR PARTS DURING REPROCESSING. THE ISSUE WAS IDENTIFIED DURING A REPROCESSING IN-SERVICE. THERE WERE NO REPORTS OF PATIENT HARM ASSOCIATED WITH THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22494797 ↗
  • MalfunctionJul 10, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE SUBJECT DEVICE WAS MISSING THE BLACK CAPS. THE ISSUE OCCURRED DURING AN UNKNOWN PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22476251 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THREE PATIENTS PRESENTED WITH SEPSIS AFTER PROCEDURES USING A CYSTO-NEPHRO VIDEOSCOPE WITH FORCEPS/IRRIGATION PLUG DEVICES. NO ADDITIONAL RELEVANT CLINICAL INFORMATION WAS PROVIDED BY THE REPORTER. OLYMPUS MADE MULTIPLE ATTEMPTS TO RECEIVE MORE INFORMATION FROM THE CUSTOMER WITHOUT SUCCESS.

    Patient problems: Sepsis

    MAUDE report 22464253 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THREE PATIENTS PRESENTED WITH SEPSIS AFTER PROCEDURES USING A CYSTO-NEPHRO VIDEOSCOPE WITH FORCEPS/IRRIGATION PLUG DEVICES. NO ADDITIONAL RELEVANT CLINICAL INFORMATION WAS PROVIDED BY THE REPORTER. OLYMPUS MADE MULTIPLE ATTEMPTS TO RECEIVE MORE INFORMATION FROM THE CUSTOMER WITHOUT SUCCESS. THIS REPORT IS RELATED TO THE FOLLOWING LINKED PATIENT IDENTIFIERS: (B)(6).

    Patient problems: Sepsis

    MAUDE report 22464226 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THREE PATIENTS PRESENTED WITH SEPSIS AFTER PROCEDURES USING A CYSTO-NEPHRO VIDEOSCOPE WITH FORCEPS/IRRIGATION PLUG DEVICES. NO ADDITIONAL RELEVANT CLINICAL INFORMATION WAS PROVIDED BY THE REPORTER. OLYMPUS MADE MULTIPLE ATTEMPTS TO RECEIVE MORE INFORMATION FROM THE CUSTOMER WITHOUT SUCCESS.

    Patient problems: Sepsis

    MAUDE report 22463456 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THREE PATIENTS PRESENTED WITH SEPSIS AFTER PROCEDURES USING A CYSTO-NEPHRO VIDEOSCOPE WITH FORCEPS/IRRIGATION PLUG DEVICES. NO ADDITIONAL RELEVANT CLINICAL INFORMATION WAS PROVIDED BY THE REPORTER. OLYMPUS MADE MULTIPLE ATTEMPTS TO RECEIVE MORE INFORMATION FROM THE CUSTOMER WITHOUT SUCCESS. THIS REPORT IS RELATED TO THE FOLLOWING LINKED PATIENT IDENTIFIERS: (B)(6).

    Patient problems: Sepsis

    MAUDE report 22463033 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: Sepsis

    MAUDE report 22462745 ↗
  • InjuryJul 9, 2025Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THREE PATIENTS PRESENTED WITH SEPSIS AFTER PROCEDURES USING A CYSTO-NEPHRO VIDEOSCOPE WITH FORCEPS/IRRIGATION PLUG DEVICES. NO ADDITIONAL RELEVANT CLINICAL INFORMATION WAS PROVIDED BY THE REPORTER. OLYMPUS MADE MULTIPLE ATTEMPTS TO RECEIVE MORE INFORMATION FROM THE CUSTOMER WITHOUT SUCCESS. THIS REPORT IS RELATED TO THE FOLLOWING LINKED PATIENT IDENTIFIERS: (B)(6).

    Patient problems: Sepsis

    MAUDE report 22462623 ↗
  • MalfunctionJun 26, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22334939 ↗
  • MalfunctionMar 17, 2025Failure to Clean Adequately; Failure to Clean Adequately

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21617820 ↗
  • MalfunctionMar 7, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21546846 ↗
  • MalfunctionOct 15, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED, THE CYSTO-NEPHRO VIDEOSCOPE WAS INCORRECTLY REPROCESSED. THE ISSUE OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: Bacterial Infection; No Clinical Signs, Symptoms or Conditions

    MAUDE report 20456132 ↗
  • MalfunctionOct 15, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED, THE FORCEPS/IRRIGATION PLUG ACCESSORY WAS INCORRECTLY REPROCESSED. THE ISSUE OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20456087 ↗
  • MalfunctionOct 15, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED, THE FORCEPS/IRRIGATION PLUG ACCESSORY WAS INCORRECTLY REPROCESSED. THE ISSUE OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20454841 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THE FACILITY WAS INTERVIEWED BY THE OLYMPUS REPRESENTATIVES AND STATED DEVIATION FROM THE REPROCESSING GUIDELINES. THE ISSUE OCCURRED DURING AN UNKNOWN EVENT AND PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20434388 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THE FACILITY WAS INTERVIEWED BY THE OLYMPUS REPRESENTATIVES AND STATED DEVIATION FROM THE REPROCESSING GUIDELINES. THE ISSUE OCCURRED DURING AN UNKNOWN EVENT AND PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20434243 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THERE WERE NO REPORTS OF PATIENT HARM OR INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20434021 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THE FACILITY WAS INTERVIEWED BY THE OLYMPUS REPRESENTATIVES AND STATED DEVIATION FROM THE REPROCESSING GUIDELINES. THE ISSUE OCCURRED DURING AN UNKNOWN EVENT AND PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20433512 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THE FACILITY WAS INTERVIEWED BY THE OLYMPUS REPRESENTATIVES AND STATED DEVIATION FROM THE REPROCESSING GUIDELINES. THE ISSUE OCCURRED DURING AN UNKNOWN EVENT AND PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20433507 ↗
  • MalfunctionOct 11, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG WAS INCORRECTLY REPROCESSED. THE FACILITY WAS INTERVIEWED BY THE OLYMPUS REPRESENTATIVES AND STATED DEVIATION FROM THE REPROCESSING GUIDELINES. THE ISSUE OCCURRED DURING AN UNKNOWN EVENT AND PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20433496 ↗
  • MalfunctionOct 9, 2024Peeled/Delaminated; Detachment of Device or Device Component; Peeled/Delaminated; Detachment of Device or Device Component

    IT WAS REPORTED THAT PEELING HAD OCCURRED ON THE INSIDE OF FORCEPS/IRRIGATION PLUG. IT WAS NOTED THAT PARTS HAD FALLEN OFF. THE ISSUE OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20407626 ↗
  • MalfunctionOct 8, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG DISASSEMBLING, CLEANING, DISINFECTING, AND THE FORCEPS STOPPER REPLACEMENT WERE NOT DONE AS DESCRIBED IN THE INSTRUCTION MANUAL LEADING TO DETERIORATION WITH USE. THE ISSUE OCCURRED DURING REPROCESSING. NO HEALTH HAZARDS HAVE BEEN REPORTED AS A RESULT OF THIS INCIDENT. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20399414 ↗
  • MalfunctionOct 8, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THAT THE FORCEPS/IRRIGATION PLUG DISASSEMBLING, CLEANING, DISINFECTING, AND THE FORCEPS STOPPER REPLACEMENT WERE NOT DONE AS DESCRIBED IN THE INSTRUCTION MANUAL LEADING TO DETERIORATION WITH USE. THE ISSUE OCCURRED DURING REPROCESSING. NO HEALTH HAZARDS HAVE BEEN REPORTED AS A RESULT OF THIS INCIDENT. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20397184 ↗
  • MalfunctionOct 8, 2024Device Reprocessing Problem; Device Reprocessing Problem

    IT WAS REPORTED THE FORCEPS/IRRIGATION PLUG WAS NOT DISASSEMBLED, CLEANED, AND DISINFECTED AS DESCRIBED IN THE INSTRUCTION MANUAL. THE ISSUE OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20395978 ↗
  • MalfunctionSep 18, 2024Device Reprocessing Problem; Device Reprocessing Problem

    OLYMPUS WAS INFORMED THAT DURING A DEMONSTRATION AND USE OF FORCEPS/IRRIGATION PLUG (ISOLATED TYPE), THE USER FACILITY STERILIZED THE DEVICE USING STERAD STERILIZATION PROCESS WITHOUT PROPER STERILIZATION SPECIFICATIONS. NO PATIENT INFECTIONS OR INJURIES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20244892 ↗

Other Choledochoscope and accessories, flexible/rigid devices

All Choledochoscope and accessories, flexible/rigid devices →