ULTRASONIC PROBE UM-S20-17S (UDI 04953170241000)Recalls & reported problems
Olympus Medical Systems Corp. · "OLA ONLY UM-S20-17S MIN. US RADIAL PROBE" · Class 2
All models of ULTRASONIC PROBE (17)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 16
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 04953170241000), received between Apr 9, 2021 and Apr 13, 2026 — classified as 2 injuries, 14 malfunctions.
The most frequently reported specific device problem is “Break” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break7
- Leak/Splash2
- Stretched2
- Deformation Due to Compressive Stress1
- Detachment of Device or Device Component1
- Device Contamination with Body Fluid1
- Fluid/Blood Leak1
- Material Fragmentation1
Patient problems
- No Clinical Signs, Symptoms or Conditions15
- Foreign Body In Patient1
Recent adverse event reports
The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 13, 2026Break
DURING THE DEVICE EVALUATION, IT WAS FOUND THAT THE TIP OF THE ULTRASONIC PROBE WAS DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24867585 ↗MalfunctionApr 13, 2026Material Fragmentation; Material Twisted/Bent
IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE ULTRASONIC PROBE HAD A BIG KINK ON THE PROBE¿S CABLE UNIT AND ALSO FOUND A PIECE OF THE LOCK PIN WAS CHIPPED OFF. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24861011 ↗MalfunctionJun 20, 2025Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THE ULTRASONIC PROBE EXHIBITED BLOOD INSIDE THE MINI PROBE. THE ISSUE OCCURRED DURING A THERAPEUTIC ENDOBRONCHIAL ULTRASOUND BRONCHOSCOPY (EBUS), WHICH WAS COMPLETED WITH AN OLYMPUS BACK-UP DEVICE AFTER A PROCEDURAL DELAY UNDER SEDATION (MORE THAN 30 MINUTES) TO CHANGE THE PROBE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22297935 ↗MalfunctionJun 12, 2024Deformation Due to Compressive Stress; Deformation Due to Compressive Stress
IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, AN INDENTATION AT THE TIP OF THE INSERTION PART WAS FOUND. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19523161 ↗MalfunctionJun 5, 2024Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT THE SUBJECT DEVICE HAD A TEAR AT THE END OF THE MINI PROBE. THE ISSUE OCCURRED PRIOR TO AN UNSPECIFIED DIAGNOSTIC PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19467066 ↗MalfunctionApr 8, 2024Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED, THE ULTRASONIC PROBE HAD A GREY WIRE THAT WAS KINKED AND PINCHED REALLY BAD. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19062289 ↗MalfunctionMar 20, 2024Break; Break
IT WAS REPORTED THE ULTRASONIC PROBE WAS BROKEN. THE ISSUE WAS FOUND DURING PREPARATION OF AN UNSPECIFIED PROCEDURE. THE PROCEDURE WAS COMPLETED USING A SIMILAR DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18943345 ↗MalfunctionMar 14, 2024Break; Break
IT WAS REPORTED THAT THE ULTRASONIC PROBE BROKE OFF DURING THE PROCEDURE. NO MESSAGES WERE DISPLAYED OTHER THAN THE PROBE STARTED CURLING FAST. THE ISSUE OCCURRED DURING BRONCHOSCOPY WITH ENDOBRONCHIAL ULTRASOUND UNDER NAVIGATION, WHICH WAS COMPLETED USING THE SAME SET OF EQUIPMENT. AN XRAY WAS DONE TO CONFIRM THAT NOTHING WAS LEFT IN THE PATIENT. THERE WERE NO REPORTS OF PROCEDURE EXTENSION AND PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18907301 ↗MalfunctionSep 6, 2023Break; Leak/Splash; Break; Leak/Splash
THE CUSTOMER REPORTED TO OLYMPUS THAT THE ULTRASONIC PROBE DID NOT PRODUCE A FULL IMAGE. THE DEVICE WAS RETURNED TO OLYMPUS FOR EVALUATION. DURING EVALUATION, THE DEVICE'S INSERTION TUBE HAD CRACKS PERFORATING THE TIP AND ULTRASOUND MEDIUM HAD LEAKED OUT. THIS MEDICAL DEVICE REPORT (MDR)IS BEING SUBMITTED TO CAPTURE THE REPORTABLE MALFUNCTION FOUND DURING EVALUATION. THE CUSTOMER REPORTED THE IMAGE ISSUE WAS DETECTED DURING INSPECTION PRIOR TO PROCEDURE. NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17693420 ↗MalfunctionJun 13, 2023Break; Leak/Splash; Break; Leak/Splash
IT WAS REPORTED THAT DURING EXAMINATION ( UNSPECIFIED PROCEDURE) WITH A BRONCHOSCOPE, THE ULTRASOUND IMAGE WAS NOT DISPLAYED FROM THE BEGINNING OF THE EXAMINATION, AND THE IMAGE WAS NOT DISPLAYED EVEN AFTER MULTIPLE REPLACEMENTS. THE INTENDED PROCEDURE WAS COMPLETED USING A SIMILAR DEVICE WITH NO PATIENT HARM OR INJURY REPORTED DUE TO THE EVENT. NO USER INJURY REPORTED. DEVICE RETURN EVALUATION FOUND IMAGE WAS NOT DISPLAYED, DAMAGE, LEAKAGE IN THE INSERTION TUBE WAS OBSERVED. THIS REPORT BEING SUBMITTED DUE TO THE FINDING OF DAMAGE, LEAKAGE IN INSERTION TUBE IDENTIFIED DURING THE DEVICE EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17115525 ↗MalfunctionFeb 2, 2023Break; Mechanical Problem; Break; Mechanical Problem
CUSTOMER REPORTED WITH "TIP IS NOT ON THE PROBE". TIP FELL OFF. NO HARM WAS REPORTED. NO PATIENT HARM, NO USER INJURY REPORTED .
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16281952 ↗MalfunctionMay 23, 2022Device Contamination with Body Fluid; Device Contamination with Body Fluid
AS REPORTED FOR THIS EVENT BY THE CUSTOMER, DURING REPROCESSING IMMEDIATELY AFTER A PROCEDURE, IT WAS OBSERVED THAT THERE WAS PRESENCE OF BLOOD INSIDE THE ULTRASOUND TIP. THERE IS NO POSSIBILITY THAT THE DEVICE WAS USED IN ANY OTHER PROCEDURE WITH THE PRESENCE OF BLOOD INSIDE THE ULTRASOUND TIP. THERE IS NO HARM TO ANY PATIENT OR PERSONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14469713 ↗MalfunctionNov 21, 2021Stretched; Stretched
THE OPERATIONS MANAGER KELLEY BARLEY FURTHER REPORTED THE REPORTED EVENT OCCURRED AT THE BEGINNING OF A BRONCHOSCOPY PROCEDURE. NO DEVICE FRAGMENT FELL INSIDE THE PATIENT AS THE PROBE BROKE BEFORE IT WAS EVER USED. THE PROCEDURE COULD NOT BE COMPLETED/ THERE WAS NO DELAY AND NO HARM TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12849897 ↗InjurySep 21, 2021Material Separation; Material Separation
IT IS REPORTED BY THE CUSTOMER, AN UNSPECIFIED PROCEDURE WAS PERFORMED USING AN ULTRASONIC PROBE. THE PROCEDURE WENT GREAT. ONCE THE PROBE WAS REMOVED FROM THE PATIENT IT WAS TAKEN TO THE REPROCESSING ROOM, WHERE IT WAS NOTICED THAT THE RADIAL TRANSDUCER (TIP) WAS MISSING FROM THE PROBE. THE PROBE IS STRETCHED ABOUT 12 INCHES LONGER THAN THEIR NEW ONE, AND IS MUCH THINNER. THE SHEATH THAT THE TRANSDUCER SITS IN IS NOT BROKEN. AN X-RAY WAS PERFORMED ON THE PATIENT AND THE TRANSDUCER WAS NOT SEEN INSIDE THE PATIENT. THE CUSTOMER CONFIRMED THERE WAS NO HARM TO THE PATIENT. ADDITIONAL DETAILS REGARDING THE PATIENT AND EVENT HAVE BEEN REQUESTED. AT THIS TIME, NO ADDITIONAL INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12503527 ↗InjurySep 21, 2021Break; Stretched
IT IS REPORTED BY THE CUSTOMER, AN UNSPECIFIED PROCEDURE WAS PERFORMED USING AN ULTRASONIC PROBE. THE PROCEDURE WENT GREAT. ONCE THE PROBE WAS REMOVED FROM THE PATIENT IT WAS TAKEN TO THE REPROCESSING ROOM, WHERE IT WAS NOTICED THAT THE RADIAL TRANSDUCER (TIP) WAS MISSING FROM THE PROBE. THE PROBE IS STRETCHED ABOUT 12 INCHES LONGER THAN THEIR NEW ONE, AND IS MUCH THINNER. THE SHEATH THAT THE TRANSDUCER SITS IN IS NOT BROKEN. AN X-RAY WAS PERFORMED ON THE PATIENT AND THE TRANSDUCER WAS NOT SEEN INSIDE THE PATIENT. THE CUSTOMER CONFIRMED THERE WAS NO HARM TO THE PATIENT. ADDITIONAL DETAILS REGARDING THE PATIENT AND EVENT HAVE BEEN REQUESTED. AT THIS TIME, NO ADDITIONAL INFORMATION HAS BEEN PROVIDED.
Patient problems: Foreign Body In Patient
MAUDE report 12503467 ↗MalfunctionApr 9, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
THE SERVICE CENTER WAS INFORMED THAT A COMPONENT DETACHED FROM THE DEVICE, WHILE ATTEMPTING TO PLACE THE STOPPER ON. THERE WAS NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11642239 ↗
Other Transducer, ultrasonic, diagnostic devices
- Site~Rite 8 Ultrasound System 9770603Bard Access Systems, Inc. · Transducer, ultrasonic, diagnostic620 reports
- ULTRASONIC PROBE UM-S20-17SOlympus Medical Systems Corp. · Transducer, ultrasonic, diagnostic2 deaths344 reports
- Transducer X7-2t 989605414122Philips Ultrasound LLC · Transducer, ultrasonic, diagnostic6 recalls21 reports
- EPIQ Diagnostic Ultrasound System 989605488741Philips Ultrasound LLC · Transducer, ultrasonic, diagnostic3 recalls165 reports
- bk3000, bk3500, bk5000, bkActiv 2300Bk Medical Aps · Transducer, Ultrasonic, Diagnostic6 recalls1 report
- Transducer L12-3 989605412072Philips Ultrasound LLC · Transducer, ultrasonic, diagnostic5 recalls1 report
- Transducer L15-7io 989605387852Philips Ultrasound LLC · Transducer, ultrasonic, diagnostic5 recalls0 reports
- Transducer eL18-4 EMT 989605431531Philips Ultrasound LLC · Transducer, ultrasonic, diagnostic5 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page