Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04987350703163), received between Aug 27, 2019 and Aug 27, 2019 — classified as 2 injuries.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break2
  • Difficult to Remove2

Patient problems

  • Device Embedded In Tissue or Plaque2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 27, 2019Break; Difficult to Remove; Break; Difficult to Remove

    THE USER FACILITY REPORTED THAT INVOLVED FINE CROSS DEVICE WAS STUCK IN LEFT ANTERIOR DESCENDING VESSEL DURING COMPLEX PERCUTANEOUS CORONARY INTERVENTION PROCEDURE. THE PATIENT WAS SCHEDULED FOR A PERCUTANEOUS CORONARY INTERVENTION AFTER TURNING DOWN CORONARY ARTERY BYPASS GRAFT A YEAR AGO. DIFFUSELY CALCIFIED LEFT ANTERIOR DESCENDING APPRECIATED WITH FLUOROSCOPY. THE FINE CROSS WAS INSERTED, VIPER WIRE INSERTED THROUGH FC, THEN WHEN TRYING TO REMOVE THE FINE CROSS, THE MD NOTICED THE MARKER WAS NOT MOVING. THE MD/STAFF WERE NOT PULLING ON THE MC. THEY DETERMINED THAT APPROXIMATELY 15 CM WERE LEFT IN THE PATIENT; AND WERE UNABLE TO SNARE THE DEVICE. THE PROCEDURE WAS REPORTED TO BE UNSUCCESSFUL. A LEFT MAIN DISSECTION WAS ALSO NOTED. THE PATIENT WENT TO EMERGENCY SURGERY FOR CORONARY ARTERY BYPASS GRAFT. THE PATIENT WAS REPORTED TO BE IN THE ICU IN STABLE CONDITION.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8935795 ↗
  • InjuryAug 27, 2019Break; Difficult to Remove; Break; Difficult to Remove

    THE USER FACILITY REPORTED THAT INVOLVED FINECROSS DEVICE WAS STUCK IN LEFT ANTERIOR DESCENDING VESSEL DURING COMPLEX PERCUTANEOUS CORONARY INTERVENTION PROCEDURE. THE PATIENT WAS SCHEDULED FOR A PERCUTANEOUS CORONARY INTERVENTION AFTER TURNING DOWN CORONARY ARTERY BYPASS GRAFT A YEAR AGO. DIFFUSELY CALCIFIED LEFT ANTERIOR DESCENDING APPRECIATED WITH FLUOROSCOPY. THE FINECROSS WAS INSERTED, VIPERWIRE INSERTED THROUGH FC, THEN WHEN TRYING TO REMOVE THE FINECROSS, THE MD NOTICED THE MARKER WAS NOT MOVING. THE MD/STAFF WERE NOT PULLING ON THE MC. THEY DETERMINED THAT APPROXIMATELY 15 CM WERE LEFT IN THE PATIENT; AND WERE UNABLE TO SNARE THE DEVICE. THE PROCEDURE WAS REPORTED TO BE UNSUCCESSFUL. A LEFT MAIN DISSECTION WAS ALSO NOTED. THE PATIENT WENT TO EMERGENCY SURGERY FOR CORONARY ARTERY BYPASS GRAFT. THE PATIENT WAS REPORTED TO BE IN THE ICU IN STABLE CONDITION.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8935793 ↗

FDA clearance and classification

The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the FINECROSS 35-1430

Has the FINECROSS 35-1430 been recalled?

No FDA recall record in our data names this exact device identifier (DI 04987350703163), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the FINECROSS 35-1430?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Aug 27, 2019. In those reports, the most common specific device problems are “Break” (2) and “Difficult to Remove” (2); the most common patient problem is “Device Embedded In Tissue or Plaque” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the FINECROSS 35-1430?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the FINECROSS 35-1430, and is it still sold?

The FDA's device database lists Terumo Corporation as the company responsible for it (brand FINECROSS, model 35-1430). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Catheter, continuous flush devices

All Catheter, continuous flush devices →