OPHTHALMIC YAG LASER SYSTEM YC-1800Recalls & reported problems
Nidek CO.,Ltd. · The ophthalmic YAG laser system YC-1800 emits Nd: YAG laser (hereafter called “YAG laser”) pulse beam by Q-switching. The YC-1800 allows the safe and bloodless treatment of intraocular diseases for outpatients by mechanical disruption caused by energy of the YAG laser pulses. The main purposes of the YC-1800 are posterior capsulotomy for secondary cataract, iridotomy for acute angle-closure glaucoma, and for pupillary membranectomy for traction retinal detachment. The YC-1800 has a slit lamp for observation that includes the YAG laser and its controlling mechanism. The YC-1800 is also equipped with an operation panel and knobs that facilitate operation. The compact and lightweight power supply box is installed separately for lightness and compactness of the system. In addition, a motorized table for the YC-1800 is available optionally. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 04987669100073), received between Aug 31, 2017 and Dec 15, 2021 — classified as 9 malfunctions.
The most frequently reported specific device problem is “Unexpected Therapeutic Results” (8 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Unexpected Therapeutic Results8
- Device Operates Differently Than Expected4
- Energy Output Problem3
- Insufficient Device Problem Information1
- Patient Device Interaction Problem1
Patient problems
- No Consequences Or Impact To Patient5
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
- Retinal Injury1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 15, 2021Unexpected Therapeutic Results; Unexpected Therapeutic Results
PLEASE SEE INITIAL MDR SUBMITTED ON 12/15/2021.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 13014645 ↗MalfunctionApr 29, 2021Unexpected Therapeutic Results; Insufficient Device Problem Information; Patient Device Interaction Problem; Unexpected Therapeutic Results; Insufficient Device Problem Information; Patient Device Interaction Problem
PLEASE SEE THE INITIAL MDR SUBMITTED ON 29-APR-2021.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 11748164 ↗MalfunctionNov 20, 2019Energy Output Problem; Energy Output Problem
PLEASE SEE INITIAL MDR SUBMISSION ON (B)(6) 2019.
Patient problems: Retinal Injury
MAUDE report 9351336 ↗MalfunctionMay 16, 2019Energy Output Problem; Unexpected Therapeutic Results; Energy Output Problem; Unexpected Therapeutic Results
PLEASE SEE THE INITIAL MDR SUBMITTED ON 16-MAY-2019.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8618016 ↗MalfunctionMay 16, 2019Energy Output Problem; Unexpected Therapeutic Results; Energy Output Problem; Unexpected Therapeutic Results
PLEASE SEE THE INITIAL MDR SUBMITTED ON 16-MAY-2019.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8617969 ↗MalfunctionApr 10, 2018Unexpected Therapeutic Results; Unexpected Therapeutic Results; Device Operates Differently Than Expected
ON CONCOMITANT MEDICAL PRODUCTS:2018, THE CUSTOMER CONTACTED NIDEK INC. FIELD SERVICE MANAGER WHO LATER COMMUNICATED TO NIDEK INC. CUSTOMER SERVICE MANAGER TO REPORT THAT THE DOCTOR OBSERVED PITTING LENS DURING SURGICAL PROCEDURE. A TOTAL OF 3 INCIDENTS WERE REPORTED AND A SEPARATE MDR WILL BE SUBMITTED FOR EACH CASE. TWO PATIENTS HAVE ACRYSOFT (B)(4) MONOFOCAL LENS AND ONE HAVE MULTIFOCAL LENS. THERE WAS NO SERIOUS ADVERSE EVENT REPORTED FROM THE USER FACILITY BUT NIDEK INC. CONSIDERS PITTING LENS ISSUE ON YC-1800 A REPORTABLE EVENT AS IT IS AN UNDESIRABLE CONDITION AND HAS A POTENTIAL TO CAUSE OR CONTRIBUTE TO A SERIOUS INJURY IF THE ISSUE WERE TO RECUR.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7420020 ↗MalfunctionApr 10, 2018Unexpected Therapeutic Results; Unexpected Therapeutic Results; Device Operates Differently Than Expected
ON (B)(6) 2018, THE CUSTOMER CONTACTED NIDEK INC. FIELD SERVICE MANAGER WHO LATER COMMUNICATED TO NIDEK INC. CUSTOMER SERVICE MANAGER TO REPORT THAT THE DOCTOR OBSERVED PITTING LENS DURING SURGICAL PROCEDURE. A TOTAL OF 3 INCIDENTS WERE REPORTED AND A SEPARATE MDR WILL BE SUBMITTED FOR EACH CASE. TWO PATIENTS HAVE ACRYSOFT SN60WF MONOFOCAL LENS AND ONE HAVE MULTIFOCAL LENS. THERE WAS NO SERIOUS ADVERSE EVENT REPORTED FROM THE USER FACILITY BUT NIDEK INC. CONSIDERS PITTING LENS ISSUE ON YC-1800 A REPORTABLE EVENT AS IT IS AN UNDESIRABLE CONDITION AND HAS A POTENTIAL TO CAUSE OR CONTRIBUTE TO A SERIOUS INJURY IF THE ISSUE WERE TO RECUR.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7419968 ↗MalfunctionApr 10, 2018Unexpected Therapeutic Results; Unexpected Therapeutic Results; Device Operates Differently Than Expected
ON (B)(6) 2018, NIDEK INC. CUSTOMER SERVICE MANAGER RECEIVED A PHONE CALL FROM A NIDEK INC. FIELD SERVICE MANAGER TO REPORT THAT A CUSTOMER (DOCTOR) WAS COMPLAINING THAT THE YAG LASER YC-1800 SERIAL (B)(4) EXPERIENCING PITTING LENSES DURING SURGERY. THERE WERE THREE PATIENTS INVOLVED DURING THE PROCEDURES, THEREBY, THREE INDIVIDUAL REPORTS WILL BE SUBMITTED. TWO PATIENTS SURGERIES WERE COMPLETED IN THE OFFICE WITHOUT ANY COMPLICATIONS AND ONE PATIENT HAD TO BE RESCHEDULED FOR LASER CAPSULOTOMY AT THE HOSPITAL AND THE SURGERY ALSO WAS COMPLETED WITHOUT ANY COMPLICATIONS. THERE WAS NO SERIOUS ADVERSE EVENTS REPORTED, PATIENTS INVOLVED DID NOT COMPLAIN OF ANY EYE COMPLICATIONS AFTER THE SURGERIES BUT NIDEK INC. CONSIDERS PITTING LENS ISSUE A REPORTABLE EVENT AS IT IS AN UNDESIRABLE CONDITION AND HAS A POTENTIAL TO CAUSE OR CONTRIBUTE TO A SERIOUS INJURY IF THE ISSUE TO RECUR.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7419964 ↗MalfunctionAug 31, 2017Unexpected Therapeutic Results; Device Operates Differently Than Expected; Unexpected Therapeutic Results; Device Operates Differently Than Expected
SEE INITIAL MDR 0002936921-2017-00022 FOR DETAILS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6836698 ↗
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page