R2P SLENGUIDE WG-S7ST1L23ARecalls & reported problems
Terumo Corporation · R2P SlenGuide Guiding Catheter · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04987892046636), received between Sep 27, 2018 and Sep 27, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 27, 2018Break; Break
THE USER FACILITY REPORTED THAT THE SLENGUIDE EXPERIENCED RESISTANCE (WHILE TRYING TO REMOVE THE WIRE) WHILE TRACKING OVER THE AMPLATZ SUPER STIFF WIRE. AFTER THE SLENGUIDE WAS REMOVED FROM THE SHEATH AND PLACED ON THE TABLE, A HOLE WAS NOTICED A COUPLE CM'S BELOW THE HUB. SINCE IT WAS THE ONLY ONE AVAILABLE, IT WAS REINTRODUCED OVER THE WIRE TO CONTINUE THE PROCEDURE. WHILE ATTEMPTING TO REMOVE IT FROM THE WIRE, IT BROKE APART WHERE IT WAS ORIGINALLY COMPROMISED. THE PATIENT CONDITION IS STABLE. THE PROCEDURE OUTCOME WAS REPORTED TO BE SUCCESSFUL. ADDITIONAL INFORMATION WAS RECEIVED ON 9/17/2018. THE PROCEDURE BEING PERFORMED WAS A SMA ANGIOPLASTY AND STENTING. NO PIECES REMAINED INSIDE THE PATIENT, IT WAS NOT BEING USED WHILE BEING REMOVED OVER THE WIRE. ADDITIONAL INFORMATION WAS RECEIVED ON 9/19/2018. RESISTANCE WAS EXPERIENCED WHEN TRYING TO REMOVE OVER THE WIRE. WHEN THE SLENGUIDE BROKE APART, THE BROKEN SEGMENT WAS LOCATED OUTSIDE OF THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7914885 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page