Skip to content

Oxford Partial Knee System 154724Recalls & reported problems

Biomet Uk Ltd · Class 3 · Implant

All models of Oxford Partial Knee System (92)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
13
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 05019279388905), received between Aug 2, 2019 and Jun 4, 2024 — classified as 13 injuries.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (4 reports).

22 other recalls cover devices cleared under the same FDA submission (P010014); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 2 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Loosening of Implant Not Related to Bone-Ingrowth4
  • Patient Device Interaction Problem3
  • Insufficient Device Problem Information2
  • Noise, Audible1
  • Unstable1

Patient problems

  • Pain6
  • Failure of Implant4
  • Insufficient Information3
  • Ambulation or Postural Difficulties2
  • Cyst(s)2
  • Loss of Range of Motion2
  • Bone Fracture(s)1
  • High Blood Pressure/ Hypertension1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT APPROXIMATELY SIX YEARS AND SIX MONTHS AFTER THE INITIAL IMPLANTATION, THE PATIENT UNDERWENT A LEFT SIDED REPLACEMENT DUE TO PAIN. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Pain

    MAUDE report 19457916 ↗
  • InjuryApr 15, 2024Unstable; Unstable

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Insufficient Information

    MAUDE report 19104016 ↗
  • InjuryApr 10, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT THE PATIENT UNDERWENT REVISION SURGERY DUE TO LOOSENING OF UNICOMPARTMENTAL COMPONENTS THREE AND A HALF YEARS POST IMPLANTATION. NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Failure of Implant

    MAUDE report 19078047 ↗
  • InjuryDec 18, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A UNI KNEE ARTHROPLASTY AND APPROXIMATELY 7 MONTHS LATER A REVISION SURGERY WAS PERFORMED DUE TO THE FAILED IMPLANT ON TIBIAL SIDE. THERE WAS A VISIBLE CYST ABOUT THE SIZE OF A MARBLE TOWARD TO POSTERIOR ASPECT OF THE TIBIA THAT WAS MOSTLY CONTAINED. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Cyst(s); Failure of Implant

    MAUDE report 18343136 ↗
  • InjuryOct 16, 2023Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Bone Fracture(s); Cyst(s); Pain

    MAUDE report 17938000 ↗
  • InjuryAug 21, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY DUE TO UNKNOWN REASON, APPROXIMATELY THREE (3) YEARS FROM THE INITIAL RIGHT KNEE ARTHROPLASTY. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Insufficient Information

    MAUDE report 17582276 ↗
  • InjuryMay 19, 2023Noise, Audible; Loosening of Implant Not Related to Bone-Ingrowth; Noise, Audible; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT APPROXIMATELY YEAR AFTER PARTIAL LEFT KNEE ARTHROPLASTY PATIENT EXPERIENCED CRACKING, POPPING AND PAIN. BONE SCAN SHOWED LOOSENING. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Ambulation or Postural Difficulties; Failure of Implant; Loss of Range of Motion; Pain

    MAUDE report 16960677 ↗
  • InjuryMay 16, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Insufficient Information

    MAUDE report 16936966 ↗
  • InjuryMar 6, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED, THAT THE PATIENT UNDERWENT A LEFT PARTIAL KNEE ARTHROPLASTY AND APPROXIMATELY 5 YEARS LATER A REVISION SURGERY WAS PERFORMED DUE TO PAIN. CONTRIBUTING FACTOR WAS DISEASE PROGRESSION. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Osteopenia/ Osteoporosis; Pain

    MAUDE report 16484003 ↗
  • InjurySep 29, 2022Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY OF THE LEFT KNEE DUE TO LOOSENING, APPROXIMATELY TWO (2) YEARS POST-OP. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: Failure of Implant

    MAUDE report 15507735 ↗
  • InjuryJan 13, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DESCRIBE EVENT OR PROBLEM. IT WAS REPORTED THAT THERE WAS A REVISION DUE TO PAIN.

    Patient problems: Pain

    MAUDE report 13248207 ↗
  • InjuryMay 1, 2020Insufficient Device Problem Information; Patient Device Interaction Problem; Insufficient Device Problem Information; Patient Device Interaction Problem

    IT WAS REPORTED THE PATIENT UNDERWENT A LEFT PARTIAL KNEE ARTHROPLASTY IN 2004. SUBSEQUENTLY, THE PATIENT CLAIMS TO BE SUFFERING FROM LOSS OF RANGE OF MOTION, INSTABILITY, HYPEREXTENSION, PAIN AND HAS TO USE A CANE TO WALK. THE REVISION IS SCHEDULED FOR (B)(6) 2020, BUT OF THAT MAY CHANGE DUE TO THE CURRENT SITUATION WITH COVID 19. INFORMATION RECEIVED STATING THAT THE REVISION SURGERY TOOK PLACE ON (B)(6) 2020.

    Patient problems: Ambulation or Postural Difficulties; High Blood Pressure/ Hypertension; Loss of Range of Motion; Pain

    MAUDE report 10016770 ↗
  • InjuryAug 2, 2019Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN INITIAL LEFT KNEE PROCEDURE. SUBSEQUENTLY, THE PATIENT WAS REVISED DUE TO SUBSIDENCE.

    Patient problems: No Code Available

    MAUDE report 8854309 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P010014. One submission often covers many models, so check the product and lot details in each record.

  • Z-1159-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Left Medial Tibial Trial Tray Size A Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1170-2017 · Jan 5, 2016 · Terminated
    Oxford Unicompartmental Knee Phase 3 Shim Size 1 Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1154-2017 · Jan 5, 2016 · Terminated
    Oxford Unicompartmental Knee Phase 3 Tibial Impactor Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1172-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Phase 3 Tibial Template Left Medial Size C Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1160-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size E Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1164-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size C Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1158-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size A Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1161-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Left Medial Tibial Trial Tray Size E Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1152-2017 · Jan 5, 2016 · Terminated
    Oxford Knee System Tibial Resector Body Tube & Guides Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1163-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Left Medial Tibial Trial Tray Size D Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1165-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size C Oxford Partial Knee System Left Medial Tibial Trial Tray Size C
  • Z-1156-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size F Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1162-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Right Medial Tibial Trial Tray Size D Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1155-2017 · Jan 5, 2016 · Terminated
    Oxford Partial Knee System Phase 3 Tibial Template Right Medial Size A Product Usage: Instruments for use with the Oxford Uni Partial Knee System
  • Z-1169-2017 · Jan 5, 2016 · Terminated
    Oxford Unicompartmental Knee Phase 3 Shim Size 2 Product Usage: Instruments for use with the Oxford Uni Partial Knee System

…and 7 more.

Other Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing devices

All Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page