TECNIS IOL ZA9003 (REF ZA90030150)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS Acry 13.omm 6OPT MODC PMMA OPTIEG · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
16
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 05050474528918), received between Dec 14, 2016 and Aug 22, 2025 — classified as 10 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Break” (9 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break9
  • Adverse Event Without Identified Device or Use Problem4
  • Device Dislodged or Dislocated3
  • Ejection Problem2
  • Material Split, Cut or Torn1
  • Physical Resistance/Sticking1

Patient problems

  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available7
  • No Clinical Signs, Symptoms or Conditions3
  • Visual Disturbances3
  • Capsular Bag Tear2
  • Corneal Edema1
  • Distress1
  • Eye Infections1
  • Eye Pain1

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 22, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED BY THE CUSTOMER THAT A LENS WAS EXPLANTED DUE TO SUBLUXATION. IT WAS REMOVED AND REPLACED DURING A SECONDARY SURGICAL PROCEDURE WITH ANOTHER JOHNSON & JOHNSON MONOFOCAL INTRAOCULAR LENS (IOL). NO UNPLANNED INCISION ENLARGEMENT OR VITRECTOMY WAS REPORTED, AND THERE WAS NO DELAY IN THE PROCEDURE. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 22874887 ↗
  • InjuryDec 30, 2024Break; Break

    IT WAS REPORTED THAT THE NON PRELOADED INTRAOCULAR LENS (IOL) HAD HAPTIC ISSUE WHEN INSERTING THE LENS IN TO THE PATIENT'S LEFT EYE. THERE WERE SUTURES AND VITRECTOMY PERFORMED. THE PATIENT IS DOING FINE. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21043725 ↗
  • InjuryJun 10, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE NON PRELOADED MONOFOCAL INTRAOCULAR LENS(IOL) WAS FULLY INSERTED, HOWEVER AFTER IMPLANTATION OR APPLICATION, THE LENS WAS DISLOCATED. IT WAS REPLACED WITH ANOTHER ZA900 LENS WITH A DIFFERENT DIOPTER IOL. A SCLERAL-FIXED LENS WAS IMPLANTED. THE PATIENT'S STATUS IS UNKNOWN. IT IS UNKNOWN IF INJURY AND MEDICAL INTERVENTION WAS REQUIRED. THE PRODUCT IS AVAILABLE FOR RETURN. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 19506976 ↗
  • MalfunctionMar 21, 2024Break; Break

    IT WAS REPORTED THAT THE HAPTIC BENT ON THE JOHNSON AND JOHNSON(JNJ) INTRAOCULAR LENS (IOL). AS THEY WERE PLACING THE LENS IN THE LEFT EYE THE HAPTIC BENT. THE IOL WAS CUT IN HALF AND REMOVED. THE LENS WAS REPLACED WITH THE SAME MODEL BUT 15.5 DIOPTER. THERE WERE NO OTHER COMPLICATIONS SUCH AS CAPSULE TEAR, VITRECTOMY, OR SUTURES. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18955813 ↗
  • MalfunctionAug 2, 2023Break; Ejection Problem; Break; Ejection Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS DEFECTIVE. THE IOL WAS PARTIALLY DELIVERED INTO THE PATIENT'S LEFT EYE AND THEN REMOVED. THE INCISION WAS ENLARGED. A VITRECTOMY AND SUTURE WERE NOT REQUIRED. THE IOL WAS REMOVED AND SUCCESSFULLY REPLACED WITH A BACK UP LENS DURING THE SAME PROCEDURE. NO OTHER INTERVENTION WERE REQUIRED. THE PATIENT WAS FINE WHEN DISCHARGED. THERE WERE NO ISSUES. THE IOL IS NOT AVAILABLE FOR RETURN. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17446705 ↗
  • MalfunctionAug 1, 2023Break; Ejection Problem; Break; Ejection Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS DEFECTIVE. THE IOL WAS PARTIALLY DELIVERED INTO THE PATIENT'S LEFT EYE AND THEN REMOVED. THE INCISION WAS ENLARGED. A VITRECTOMY AND SUTURE WERE NOT REQUIRED. THE IOL WAS REMOVED AND SUCCESSFULLY REPLACED WITH ANOTHER JOHNSON & JOHNSON LENS, MODEL ZA9003 15.5 DIOPTER DURING THE SAME PROCEDURE. NO OTHER INTERVENTION WERE REQUIRED. THE PATIENT WAS FINE WHEN DISCHARGED. THERE WERE NO ISSUES. THE IOL IS NOT AVAILABLE FOR RETURN. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17439371 ↗
  • InjuryMar 2, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    RECEIVED REPORT OF AN EXPLANT OF AN IOL (INTRAOCULAR LENS) THAT HAD BEEN IMPLANTED 13 YEARS AGO. THE IOL WAS DISPLACED IN THE EYE. IT¿S UNKNOWN IF THE ISSUE WAS AFFECTING THE PATIENT¿S DAILY ACTIVITIES. THE IOL WAS EXPLANTED. AN UNPLANNED VITRECTOMY OCCURRED. NO SUTURES WERE USED.THE REPLACEMENT LENS IS THE SAME MODEL BUT DIFFERENT DIOPTER, ZA9003 +13.5 DIOPTER. REPORTEDLY, THE PATIENT HAS FULLY RECOVERED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 16473126 ↗
  • InjuryNov 14, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S RIGHT EYE DUE TO DYSPHOTOPSIA. THERE WAS NO VITRECTOMY, INCISION ENLARGEMENT, OR SUTURES REQUIRED. A NON-JOHNSON & JOHNSON LENS WAS IMPLANTED AS A REPLACEMENT. THE PATIENT HAS FULLY RECOVERED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Visual Disturbances

    MAUDE report 15795068 ↗
  • InjuryMay 9, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED AFTER THE INTRAOCULAR LENS (IOL) WAS INSERTED INTO THE PATIENT'S OCULAR SINISTER (LEFT EYE) THE DOCTOR DID NOT THINK IT WOULD HOLD. THE IOL WAS REMOVED AND NO LENS WAS IMPLANTED. THE INCISION WAS ENLARGED AND SUTURE(S) WERE REQUIRED. THROUGH FOLLOW-UP, ADDITIONAL INFORMATION WAS RECEIVED CONFIRMING THE PATIENT DID HAVE PRIOR EYE HISTORY THAT CONTRIBUTED TO THE EVENT, 2X RETINAL SURGERY PRIOR TO IOL IMPLANT. THERE WAS NO PRODUCT QUALITY ISSUE THAT CONTRIBUTED TO THE EVENT. PATIENT OUTCOME POST-PROCEDURE WAS REPORTED AS FINE. THE PATIENT HAS SURGERY SCHEDULED WITH A RETINA SURGEON. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 14342735 ↗
  • InjuryOct 28, 2021Break; Physical Resistance/Sticking; Break; Physical Resistance/Sticking

    IT WAS REPORTED THAT WHEN THE INTRAOCULAR LENS (IOL) WAS FULLY INSERTED INTO ANTERIOR CHAMBER OF PATIENT'S RIGHT EYE, BUT BEFORE INSIDE THE CAPSULAR BAG, IT WAS NOTED THAT THE LEAD HAPTIC CRIMPED AND STUCK TO THE OPTIC OF THE LENS. THE CAPSULAR BAG WAS RENTED. THE INCISION WAS ENLARGED AND THE LENS WAS REMOVED AND A REPLACEMENT LENS OF SAME MODEL AND DIOPTER WAS FIXED TO THE SULCUS. SUTURE WAS PLACED. THE PATIENT WAS DOING FINE POST OPERATION. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: Capsular Bag Tear

    MAUDE report 12716036 ↗
  • InjuryMay 5, 2021Break; Break

    A PATIENT REPORTED HAVING UNDERGONE CATARACT SURGERY IN THE LEFT EYE IN (B)(6) 2020. AFTER THE LENS WAS INSERTED INTO THE EYE AND UNFOLDED, THE DOCTOR NOTICED THAT THE TRAILING HAPTIC WAS BROKEN. IT WAS INDICATED THAT THE TRAILING HAPTIC PIERCED THE CAPSULE; THEREFORE, THE INCISION WAS ENLARGED AND THE LENS WAS REMOVED FROM THE EYE ON THE SAME DAY. A REPLACEMENT LENS FROM A DIFFERENT COMPANY WAS IMPLANTED AND A SUTURE WAS USED. THE PATIENT HAD SOME EDEMA/SWELLING. ON THE NEXT DAY POST-OPERATIONAL VISIT, THE COMPETITOR¿S LENS HAD DISLOCATED AND AT THAT POINT, THE PATIENT WAS REFERRED TO A RETINA SPECIALIST WHO PERFORMED A VITRECTOMY ON THE EYE. THE PATIENT COMPLAINED OF FLOATERS IN HER EYE WITH HER CURRENT COMPETITOR¿S IMPLANT AND INDICATED THAT SHE HAS HAD SEVERAL SURGERIES SINCE HER CATARACT SURGERY. THE PATIENT REPORTED HAVING UNDERGONE A CORNEA TRANSPLANT AND REPORTEDLY NOW MAY HAVE GLAUCOMA. THE PATIENT DOES NOT SEE WELL OUT OF LEFT EYE AND HER VISION IS BETTER IN THE MORNING, BUT TERRIBLE IN THE EVENINGS. THE PATIENT IS ABLE TO PERFORM HER DAILY TASKS; HOWEVER, SHE STILL HAS PAIN IN HER EYE WITH THE CURRENT IMPLANT. THE PATIENT HAS A JOHNSON AND JOHNSON LENS IN HER RIGHT EYE W

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Bag Tear; Corneal Edema; Distress; Eye Infections; Eye Pain; Glaucoma; Intraocular Pressure Increased; Visual Disturbances; Visual Impairment; Vitreous Floaters; Vitreous Loss

    MAUDE report 11780848 ↗
  • InjuryMay 5, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A TECNIS INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S LEFT (OS) EYE IN A SECONDARY PROCEDURE DUE TO HAVING DYSPHOTOPSIA. THE INCISION WAS ENLARGED, BUT NO HARM OR INJURY TO THE PATIENT. THE REPLACEMENT LENS IS AN EYEKON S102, 14.5 DIOPTERS. NO FURTHER INFORMATION PROVIDED.

    Patient problems: Visual Disturbances

    MAUDE report 11779666 ↗
  • MalfunctionMar 17, 2021Break; Break

    IT WAS REPORTED THAT THE TECNIS INTRAOCULAR LENS (IOL) HAPTIC WAS BENT, AND THERE WAS PATIENT CONTACT. NO FURTHER INFORMATION PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11506649 ↗
  • InjuryDec 10, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A MODEL ZA9003 INTRAOCULAR LENS(IOL) WAS EXPLANTED FROM PATIENT'S LEFT EYE IN A SECONDARY SURGICAL PROCEDURE BECAUSE OF REFRACTIVE SURPRISE. NO MEDICAL/SURGICAL INTERVENTIONS SUCH AS VITRECTOMY, SUTURES OR INCISION ENLARGEMENT WERE PERFORMED. THE REPLACEMENT LENS USED IS A SAME MODEL BUT HIGHER DIOPTER 18.0. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Code Available; Therapeutic Effects, Unexpected

    MAUDE report 10984598 ↗
  • MalfunctionJan 14, 2019Break; Material Split, Cut or Torn; Break; Material Split, Cut or Torn

    IT WAS REPORTED THAT INTRAOCULAR LENS HAD TORN OR BROKEN HAPTIC. NO FURTHER INFORMATION PROVIDED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8246766 ↗
  • MalfunctionDec 14, 2016Break; Break

    A BROKEN HAPTIC WAS REPORTED. THERE WAS PATIENT CONTACT. THE INTRAOCULAR LENS (IOL) WAS FULLY INSERTED. THERE WAS NO INCISION ENLARGEMENT. AN ANTERIOR VITRECTOMY WAS PERFORMED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A BACK-UP LENS. NO ADDITIONAL INFORMATION WAS PROVIDED TO ABBOTT MEDICAL OPTICS.

    Patient problems: Vitrectomy

    MAUDE report 6172809 ↗

Other intraocular lens devices

All intraocular lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page