TECNIS IOL ZA9003 (REF ZA90030275)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS Acry 13.omm 6OPT MODC PMMA OPTIEG · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474529168), received between May 27, 2017 and Nov 21, 2023 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Material Split, Cut or Torn” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Split, Cut or Torn2
  • Break1
  • Inaccurate Delivery1
  • Scratched Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Patient Involvement1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 21, 2023Break; Break

    IT WAS REPORTED THAT AFTER LENS IMPLANTATION, ON THE FIRST DAY AFTER SURGERY, DOCTOR FOUND THAT THE LENS HAPTIC IN THE PATIENT'S EYE WAS DAMAGED AND HAD TO BE EXPLANTED AND REPLACED. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18187914 ↗
  • MalfunctionApr 3, 2023Material Split, Cut or Torn; Material Split, Cut or Torn

    IT WAS REPORTED THAT THE ZA9003 INTRAOCULAR LENS (IOL) WAS INSERTED INTO PATIENT'S OPERATIVE EYE, HOWEVER, HAD TO BE REMOVED AS IT WAS TORN. ANOTHER COMPETITOR LENS WAS USED AS THE REPLACEMENT. NO FURTHER INFORMATION WAS PROVIDED. THIS REPORT IS FOR THE ZA9003, SN (B)(4)P. A SEPARATE REPORT WILL BE SUBMITTED FOR THE OTHER ZA9003 INTRAOCULAR LENS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16671285 ↗
  • MalfunctionMar 31, 2023Material Split, Cut or Torn; Material Split, Cut or Torn

    IT WAS REPORTED THAT THE ZA9003 INTRAOCULAR LENS WAS INSERTED INTO PATIENT'S OPERATIVE EYE, HOWEVER, HAD TO BE REMOVED AS IT WAS TORN. ANOTHER COMPETITOR LENS WAS USED AS THE REPLACEMENT. ADDITIONAL INFORMATION RECEIVED FROM THE FACILITY REVEALED THAT THERE WAS NO PATIENT INJURY AND NO OTHER MEDICAL/SURGICAL INTERVENTION WAS REQUIRED. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16660178 ↗
  • MalfunctionSep 17, 2021Inaccurate Delivery; Inaccurate Delivery

    IT WAS REPORTED THAT PARTIALLY INSERTED INTRAOCULAR LENS (IOL) FOR THE RIGHT EYE OF A PATIENT WAS REMOVED AND REPLACED IN THE SAME PROCEDURE DUE TO TRAILING HAPTIC NOT FOLDED. THE LENS DID CONTACT THE PATIENT EYE. THERE WERE NO MEDICAL/SURGICAL INTERVENTIONS REQUIRED. THE LENS WAS DISCARDED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12488829 ↗
  • MalfunctionMay 27, 2017Scratched Material; Scratched Material

    IT WAS REPORTED THAT A SCRATCH WAS NOTICED ON AN INTRAOCULAR LENS (IOL) WHEN OPENING THE LENS CASE. NO PATIENT CONTACT WAS REPORTED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Patient Involvement

    MAUDE report 6596224 ↗

Other intraocular lens devices

All intraocular lens devices →