TECNIS IOL ZMB00 (REF ZMB00U0225)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS MF 1- PIECE 6.0MM 22.5 US · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 9
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 05050474535671), received between Dec 8, 2016 and Apr 13, 2021 — classified as 9 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem9
Patient problems
- No Code Available7
- Halo3
- Capsular Bag Tear1
- Dry Eye(s)1
- Visual Disturbances1
- Visual Impairment1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
InjuryApr 13, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED IN A SECONDARY SURGICAL PROCEDURE DUE TO THE TEAR OF THE CAPSULAR BAG. A REPLACEMENT LENS OF A DIFFERENT MODEL AND DIOPTER (21.5 D) WAS IMPLANTED ON CINGULATE MOTOR AREA (CMA) SULCUS. IT WAS INDICATED THAT THE ISSUE WAS FIRST NOTICED AT THE SURGERY. THERE WERE NO SURGICAL INTERVENTIONS SUCH AS VITRECTOMY, INCISION ENLARGEMENT OR SUTURES REQUIRED. THERE WAS NO PATIENT INJURY REPORTED. THE PATIENT OUTCOME AT THE TIME DISCHARGE WAS REPORTED TO BE VERY WELL. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Capsular Bag Tear
MAUDE report 11661983 ↗InjuryJul 10, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT DUE TO THE PATIENT BEING DISSATISFIED. THE EXPLANTED LENS WAS DISCARDED. THERE WAS NO PATIENT INJURY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED TO JOHNSON & JOHNSON SURGICAL VISION.
Patient problems: No Code Available
MAUDE report 8778862 ↗InjuryMay 23, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED POST-IMPLANT OF A MODEL ZMB00 22.5 DIOPTER INTRAOCULAR LENS, THE PATIENT EXPERIENCED UNEXPECTED POST-OP REFRACTION DUE TO A DISCREPANCY IN LENS POWER. THE LENS WAS EXPLANTED ON (B)(6) 2019 AND SUCCESSFULLY REPLACED WITH ANOTHER ZMB00 OF A LOWER DIOPTER (21.0). THERE WAS NO INCISION ENLARGEMENT, VITRECTOMY OR SUTURES REQUIRED. NO PATIENT INJURY REPORTED. OUTCOME WAS NOTED TO BE NORMAL. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Code Available
MAUDE report 8635075 ↗InjuryFeb 5, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A FEMALE PATIENT WAS EXPERIENCING VISUAL DISTURBANCE AND DRY EYES AFTER BILATERAL IMPLANTATION OF A ZMB00 INTRAOCULAR LENSES. SHE REGRETS HAVING GONE THROUGH CATARACT SURGERY AT THE END OF 2014 SINCE SHE ENDED UP WEARING PRESCRIPTION GLASSES FOR BOTH EYES (OU). SHE WAS ALSO UNABLE TO DRIVE AT NIGHT AS STREET LIGHTS AND AUTOMOBILE LIGHTS CREATE HALOS THAT INTERFERE WITH HER SEEING WELL. HER VISION ISSUES HAVE NOT IMPROVED. THROUGH FOLLOW-UP, THE PATIENT CONFIRMED THAT HER EYES ARE SENSITIVE TO LIGHT. SHE MUST WEAR SUNGLASSES ALL THE TIME AS EVERYTHING IS TOO BRIGHT FOR HER EYES. SHE DRIVES DURING THE DAY WITH SUNGLASSES, BUT SHE DOESN'T DRIVE AT NIGHT BECAUSE OF THE HALOS. SHE DIDN'T START NOTICING HER SYMPTOMS UNTIL AFTER THE SECOND LENS (RIGHT EYE) WAS IMPLANTED. SHE DOES NOT REMEMBER THE EXACT DATE WHEN SHE NOTICED ANY OF THE VISION CHANGES. HER EYES BECAME DRY, SO SHE WAS USING EYE DROPS SHORTLY AFTER. THE DOCTOR DID PERFORM A LASER PROCEDURE, BUT SHE DOES NOT REMEMBER WHAT KIND OF LASER, AND IT DID NOT HELP WITH HER VISION. THERE ARE NO PLANS TO REMOVE OR REPLACE THE LENS. SHE IS NOT HAPPY WITH THE OUTCOME. NO ADDITIONAL INFORMATION PROVIDED. THIS REPORT PE
Patient problems: Dry Eye(s); Halo; Visual Disturbances
MAUDE report 8303698 ↗InjuryApr 26, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A ZMB00 22.5 DIOPTER LENS WAS IMPLANTED INTO THE PATIENT'S LEFT EYE (OS) ON (B)(6) 2018, BUT WAS LATER EXPLANTED ON (B)(6) 2018. THERE WAS NO INCISION ENLARGEMENT, NO VITRECTOMY, AND ONE SUTURE WAS USED TO SEAL THE WOUND. REPORTEDLY, THERE WAS NO PATIENT INJURY AND THE PATIENT IS DOING FINE POST-OPERATIVELY. THE REPLACEMENT LENS WAS A NON-JOHNSON AND JOHNSON LENS. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Halo; No Code Available
MAUDE report 7466766 ↗InjuryMar 7, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A ZMB00 22.5 DIOPTER INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE PATIENT'S LEFT EYE (OS) ON (B)(6) 2018. IT WAS LATER EXPLANTED ON (B)(6) 2018, BECAUSE THE PATIENT EXPERIENCED A SIGNIFICANT AMOUNT OF GLARE AND DUE TO PSEUDOPHAKIA WITH ASTHENOPIA. REPORTEDLY, THESE OUTCOMES SIGNIFICANTLY INTERFERED WITH ACTIVITIES OF DAILY LIFE. IT IS UNKNOWN IF AN INCISION ENLARGEMENT WAS PERFORMED, BUT IT WAS CONFIRMED THAT A VITRECTOMY WAS NOT PERFORMED. REPORTEDLY, THERE WAS NO PATIENT INJURY AND NO ISSUES HAVE BEEN REPORTED POST-OPERATIVELY. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 7322011 ↗InjuryOct 7, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A MULTIFOCAL INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE LEFT EYE OF A MALE PATIENT ON (B)(6) 2017. EXPLANT WAS DUE TO UNEXPECTED POSTOP REFRACTION. IT WAS REPORTED THAT THE SYMPTOMS WERE AFFECTING THE PATIENT'S DAILY ACTIVITIES. THE LENS WAS REPLACED WITH THE SAME MODEL, A SMALLER 21.0 DIOPTER LENS. THERE WAS NO INCISION ENLARGEMENT REPORTED.
Patient problems: No Code Available
MAUDE report 6927631 ↗InjurySep 20, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A ZMB00 22.5 DIOPTER INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE RIGHT EYE (OD) ON (B)(6) 2013. IT WAS LATER EXPLANTED ON (B)(6) 2017 DUE REFRACTIVE ERROR, POOR VISION, HALOS, AND GLARE. THE LENS WAS REPLACED WITH A DIFFERENT MODEL. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Halo; No Code Available; Visual Impairment
MAUDE report 6878220 ↗InjuryDec 8, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT IS NOT ABLE TO SEE NEAR AND FAR SIGHTED AFTER IMPLANTATION OF A ZMB00 22.5 DIOPTER INTRAOCULAR LENS (IOL) IN HIS RIGHT EYE. THE PATIENT NOTED THE DOCTOR STATED THAT HE DEVELOPED SECONDARY CATARACTS AFTER THE CATARACTS WERE REMOVED THE PATIENT STILL HAD ISSUES WITH HIS VISION. THE PATIENT STATES THAT HE IS ABLE TO DRIVE BUT HAS A DIFFICULTY SEEING. HE VISITED ANOTHER DOCTOR FOR A SECOND OPINION AND THE DOCTOR PRESCRIBED THE PATIENT EYEGLASSES. THE GLASSES HELPED A LITTLE BIT. THE ZMB00 IMPLANTED ON THE RIGHT EYE IS BEING CAPTURED IN THIS REPORT AND A SEPARATE MDR IS BEING FILED FOR THE ZKB00 IMPLANTED ON THE LEFT EYE.
Patient problems: No Code Available
MAUDE report 6157136 ↗
Other LENS, MULTIFOCAL INTRAOCULAR devices
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular144 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular1 recall66 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular113 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular112 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular110 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular107 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular104 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular93 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page