SENSAR IOL AAB00 (REF AAB0000170)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · SENSAR 1-PC CLEAR MONO 6.0MM 17.0D · Class 3 · Implant
All models of SENSAR IOL (112)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05050474548602), received between Oct 19, 2018 and Apr 18, 2023 — classified as 4 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Break1
- Contamination1
- Device Dislodged or Dislocated1
- Material Opacification1
Patient problems
- Capsular Bag Tear2
- No Clinical Signs, Symptoms or Conditions2
- Vitrectomy2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Blurred Vision1
- No Code Available1
- Visual Impairment1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryApr 18, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THE INTRAOCULAR LENS WAS IMPLANTED INTO THE PATIENT¿S OCULAR DEXTER (RIGHT EYE). THE IOL WAS EXPLANTED IN A SECONDARY SURGICAL PROCEDURE DUE TO IOL SUBLUXATED 50%, DOUBLE VA (VISUAL ACUITY), AND FOGGY. REPLACEMENT LENS INFORMATION IS UNKNOWN. THERE WAS NO INCISION ENLARGEMENT NO SUTURE(S), NO MEDICAL ATTENTION WAS REQUIRED AND NO MEDICATION (OUTSIDE OF STANDARD CARE) WAS PRESCRIBED HOWEVER, AN UNPLANNED VITRECTOMY WAS PERFORMED. BEST CORRECTED VISUAL ACUITY PRE-OPERATIVE: 20/50+2 AND BEST CORRECTED VISUAL ACUITY POST-OPERATIVE: 20/20-1. PATIENT STATUS WAS REPORTED AS FULLY RECOVERED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Blurred Vision; Visual Impairment
MAUDE report 16763138 ↗MalfunctionJan 13, 2023Break; Break
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS INSERTED INTO THE LEFT EYE WITH A BENT HAPTIC. THE LENS WAS THEN CUT OUT AND REPLACED WITH ANOTHER JOHNSON AND JOHNSON IOL (SAME MODEL, SAME DIOPTER). THE PATIENT IS DOING WELL. THE PATIENT HAS POOR VISION BY HISTORY DUE TO AGE-RELATED MACULAR DEGENERATION (AMD). THE DEVICE WAS DISCARDED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16164280 ↗InjuryJan 13, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ONCE THE INTRAOCULAR LENS (IOL) WAS INSERTED INTO THE LEFT EYE, THE DOCTOR NOTICED A CAPSULE TEAR. THE LENS WAS CUT OUT AND REPLACED WITH A NON-JOHNSON AND JOHNSON IOL (SAME DIOPTER). THE PATIENT IS DOING WELL. THE PATIENT HAS POOR VISION BY HISTORY DUE TO AGE-RELATED MACULAR DEGENERATION (AMD). THE DEVICE WAS DISCARDED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Capsular Bag Tear
MAUDE report 16164149 ↗MalfunctionJan 12, 2021Contamination; Material Opacification; Contamination; Material Opacification
IT WAS REPORTED THAT AFTER IMPLANTATION A GLISTENING WAS NOTED IN ONE HALF OF THE INTRAOCULAR LENS (IOL) OPTIC, BUT NO LENS DAMAGE WAS VISIBLE. THE LENS WAS REMOVED AND REPLACED. THE MATERIAL IS AVAILABLE, AND NO PATIENT ISSUES WERE REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11153077 ↗InjuryMay 19, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CUSTOMER IMPLANTED AN AAB00 SENSAR ONE-PIECE MONOFOCAL INTRAOCULAR LENS (IOL), HOWEVER, AN ANTERIOR VITRECTOMY WAS REQUIRED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Vitrectomy
MAUDE report 10073325 ↗InjuryOct 19, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AS THE SURGEON TOOK SILICONE OIL OUT OF THE PATIENT'S LEFT EYE (OS) DURING AN IMPLANTATION OF AN AAB00 17.0 DIOPTER LENS, IT WAS NOTICED THAT THE PATIENT'S CAPSULE WAS WEAK AND THE LENS FELL DOWN INTO THE POSTERIOR CHAMBER. THERE WAS AN INCISION ENLARGEMENT AND VITRECTOMY PERFORMED, INCLUDING SUTURES BEING USED. THE REPLACEMENT LENS WAS A NON-JOHNSON AND JOHNSON LENS. THERE WAS NO PATIENT INJURY AND THE PATIENT IS DOING FINE POST-OPERATIVELY. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: Capsular Bag Tear; No Code Available; Vitrectomy
MAUDE report 7986254 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page