Skip to content

SENSAR IOL AAB00 (REF AAB0000230)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · SENSAR 1-PC CLEAR MONO 6.0MM 23.0D · Class 3 · Implant

All models of SENSAR IOL (112)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 05050474548725), received between Feb 2, 2017 and Apr 29, 2026 — classified as 7 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5
  • Break4
  • Contamination2
  • Contamination /Decontamination Problem1
  • Failure to Fold1
  • Improper or Incorrect Procedure or Method1
  • Mechanical Jam1
  • Scratched Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Code Available3
  • Capsular Bag Tear2
  • No Consequences Or Impact To Patient1
  • No Patient Involvement1
  • Visual Disturbances1
  • Vitrectomy1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 29, 2026Contamination

    IT WAS REPORTED THAT THE SURGEON FOUND SOME FOREIGN SUBSTANCE ON THE OPTIC AFTER IMPLANTATION OF THE INTRAOCULAR LENS (IOL) INTO THE PATIENT¿S EYE. THE IOL STILL REMAINS IMPLANTED IN THE PATIENT¿S EYE. THERE WAS NO DELAY IN TREATMENT OR OTHER INTERVENTIONS PERFORMED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25034175 ↗
  • InjuryAug 14, 2025Break; Break

    IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE WITH A NON-PRELOADED MONOFOCAL INTRAOCULAR LENS (IOL), THE INJECTOR MALFUNCTIONED, RESULTING IN THE LENS BECOMING STUCK AFTER APPROXIMATELY 70% HAD BEEN INJECTED INTO THE PATIENT'S RIGHT EYE. THE SURGEON ATTEMPTED TO ADVANCE THE LENS FURTHER, BUT IT OVERSHOT, CAUSING AN EXTENDED CONTINUOUS CURVILINEAR CAPSULORHEXIS (CCC) AND A POSTERIOR CAPSULE RENT. CONSEQUENTLY, THE SDANT INTRAOCULAR LENS WAS IMPLANTED. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Capsular Bag Tear

    MAUDE report 22811991 ↗
  • MalfunctionJun 8, 2022Break; Failure to Fold; Mechanical Jam; Break; Failure to Fold; Mechanical Jam

    IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS DEFECTIVE. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14639111 ↗
  • MalfunctionFeb 24, 2022Break; Break

    IT WAS REPORTED THAT THE CUSTOMER INDICATED IN CORRESPONDENCE THAT THERE WAS A DEFECT. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13596506 ↗
  • MalfunctionJul 15, 2021Break; Scratched Material; Break; Scratched Material

    IT WAS REPORTED THAT THE SURGEON CHECKED THE IOL BEFORE THE SURGERY. HOWEVER, AFTER IMPLANTING THE IOL INTO THE PATIENT¿S OPERATIVE EYE, HE FOUND THAT SOME "CURVE" ON THE SURFACE OF THE IOL. PATIENT DIDN¿T HAVE ANY PROBLEMATIC REACTION AND THE IOL REMAINS IMPLANTED. THE SURGEON IS NOT PLANNING ANY SURGICAL INTERVENTION. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12175865 ↗
  • InjuryMay 21, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT HAD AN ANTERIOR VITRECTOMY PERFORMED WITH AN INTRAOCULAR LENS (IOL). NO ADDITIONAL INFORMATION WAS PROVIDED TO JOHNSON & JOHNSON SURGICAL VISION.

    Patient problems: Vitrectomy

    MAUDE report 10081270 ↗
  • InjuryOct 12, 2019Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    IT WAS REPORTED THAT INTRAOCULAR LENS (IOL) WAS INCORRECTLY LOADED INTO THE CARTRIDGE AND WAS FOUND TO BE UPSIDE DOWN WHEN INSERTED INTO THE PATIENT'S LEFT EYE. THE LENS WAS REMOVED AND REPLACED WITH THE BACK UP LENS. INCISION ENLARGEMENT WAS PERFORMED ALONG WITH SUTURES. NO VITRECTOMY DONE. PATIENT WAS DOING FINE POST-OP. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Code Available

    MAUDE report 9183201 ↗
  • MalfunctionMay 20, 2019Contamination; Contamination

    IT WAS REPORTED THAT THERE WAS RESIDUE ON INTRAOCULAR LENS. THERE WAS PATIENT CONTACT AND NO PATIENT INJURY. ADDITIONAL INFORMATION WAS RECEIVED, AND IT WAS LEARNT THAT LENS WAS NOT INSERTED, REMOVED AND REPLACED. NO INCISION ENLARGEMENT, NO SUTURES, NO VITRECTOMY WAS REQUIRED. PATIENT WAS DOING GOOD. NO FURTHER INFORMATION PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8625180 ↗
  • InjuryMar 21, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS EXPLANTED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Code Available

    MAUDE report 8442197 ↗
  • MalfunctionJan 7, 2019Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED THAT THE LENS HAD A FIBER OR HAIR ON THE OPTIC BODY. ADDITIONAL INFORMATION WAS RECEIVED AND IT WAS LEARNT THAT THE LENS WAS INSPECTED BEFORE PLACEMENT AND NOT USED SO THERE WAS NO PATIENT INVOLVEMENT. NO FURTHER INFORMATION PROVIDED.

    Patient problems: No Patient Involvement

    MAUDE report 8224657 ↗
  • InjuryOct 9, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT WHEN THE INTRAOCULAR LENS (IOL) WAS STARTED TO BE INJECTED INTO THE EYE, BREAKAGE OF THE EDGE OF THE PATIENT'S CAPSULAR BAG OCCURRED. REPORTEDLY, THE IMPLANTATION WAS STOPPED AND A 3-PIECE LENS WAS IMPLANTED INSTEAD. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Capsular Bag Tear

    MAUDE report 7949038 ↗
  • InjuryNov 16, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN AAB00 23.0 DIOPTER INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE RIGHT EYE (OD) ON (B)(6) 2017. IT WAS LATER EXPLANTED ON (B)(6) 2017 BECAUSE THE INCORRECT LENS SIZE WAS IMPLANTED. THERE WAS NO VITRECTOMY PERFORMED AND NO COMPLICATIONS SUCH AS A CAPSULAR TEAR. THE LENS WAS REPLACED WITH A ZCT150 18.5 DIOPTER IOL. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Code Available

    MAUDE report 7039458 ↗
  • InjuryFeb 2, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY A PATIENT THAT SHE EXPERIENCED REFRACTIVE DIFFICULTIES WITH HER INTRAOCULAR LENSES. THE PATIENT HAD CATARACT SURGERY ON THE LEFT EYE (B)(6) 2016, AND CATARACT SURGERY ON HER RIGHT EYE (B)(6) 2016. BEFOREHAND, THE PATIENT STATED SHE WAS SHORT-SIGHTED IN THE LEFT EYE AND LONG-SIGHTED (OR FAR-SIGHTED) IN THE RIGHT EYE. AFTER SURGERY, SHE HAD VISUAL DIFFICULTIES AND CANNOT SEE WELL EITHER NEAR OR FAR AND CANNOT GET GLASSES DUE TO THE DIOPTERS. THE PATIENT WANTED TO KNOW WHAT KIND OF LENSES SHE HAS; ARE THEY ASPHERIC LENSES AND WHY WERE DIFFERENT DIOPTERS IMPLANTED. THE LENSES REMAIN IMPLANTED. NO FURTHER INFORMATION WAS PROVIDED. THE PATIENT REPORTS TWO LENSES AND RELATED SYMPTOMS. AN MDR WILL BE FILED FOR EACH EYE. THIS REPORT REPRESENTS THE LENS IMPLANTED IN THE PATIENT'S RIGHT EYE.

    Patient problems: Visual Disturbances

    MAUDE report 6295409 ↗

Other intraocular lens devices

All intraocular lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page