Skip to content

TECNIS IOL ZCT150 (REF ZCT150U100)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC 1-PIECE 6.0MM 10.0D CYL1.50 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05050474551947), received between Nov 16, 2020 and Nov 16, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Device Dislodged or Dislocated1

Patient problems

  • Blurred Vision1
  • No Code Available1
  • Vitrectomy1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 16, 2020Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT A MODEL ZCT150 INTRAOCULAR LENS (IOL) WAS REPOSITIONED DUE TO PSEUDOPHAKODONESIS. MEDICAL/SURGICAL INTERVENTIONS THAT WERE PERFORMED ARE IOL REPOSITIONING, PARS PLANA VITRECTOMY (PPV), USE OF CAPSULAR RETRACTORS, CAPSULAR TENSION SET RING, AND PLACEMENT OF 2 CAPSULE TENSION SEGMENTS SUTURED IN PLACE. PATIENT IS HAPPY WITH THE VISION AND IOL IS IN GOOD POSITION. ADDITIONAL DETAILS RECEIVED STATES THAT THERE IS NO "DEGREE" OF ROTATION OF THE IOL AND THE REASON FOR THE REPOSITIONING WAS PSEUDOPHAKODONESIS - WHICH IS MOVEMENT/JIGGLING OF THE IOL. PATIENT'S FIRST COMPLAINT OF BLURRY VISON IN THE RIGHT EYE (OD) WAS ON (B)(6) 2019. VISION WAS 20/25+2 WITH CORRECTION. DOCTOR DOCUMENTED PSEUDOPHAKODONESIS THEN ADVISED TO OBSERVE. PATIENT RETURNED ON (B)(6) 2020 WITH THE SAME COMPLAINT OF BLURRY VISION - 20/25 WITH CORRECTION IN THE RIGHT EYE AND ADVISED TO OBSERVE. PATIENT RETURNED AGAIN ON (B)(6) 2020 WITH COMPLAINT OF BLURRY VISION - 20/30 WITH CORRECTION THEN DOCTOR ADVISED SURGERY TO LASSO THE IOL. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Blurred Vision; No Code Available; Vitrectomy

    MAUDE report 10849062 ↗

Other LENS, INTRAOCULAR, TORIC OPTICS devices

All LENS, INTRAOCULAR, TORIC OPTICS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page