TECNIS IOL ZCT225 (REF ZCT225U080)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC 1-PIECE 6.0MM 8.0D CYL2.25 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05050474552494), received between Mar 23, 2017 and Mar 31, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Unintended Movement” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Unintended Movement2
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 31, 2017Unintended Movement; Unintended Movement
IT WAS REPORTED THAT AFTER IMPLANTATION OF A ZCT225 8.0 DIOPTER INTRAOCULAR LENS (IOL), THE LENS HAD ROTATED 10 DEGREES. THE INITIAL AXIS OF IMPLANTATION WAS 97 DEGREES. AT THE ONE MONTH POST OP VISIT, THE AXIS WAS MEASURED AT 87 DEGREES. THE PATIENT DID NOT REPORT ANY ISSUES. THE LENS REMAINS IMPLANTED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6451377 ↗MalfunctionMar 23, 2017Unintended Movement; Unintended Movement
IT WAS REPORTED THAT A TECNIS TORIC INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE LEFT EYE OF A (B)(6) MALE PATIENT. THE IOL, INITIALLY PLACED AT 97 DEGREES, WAS MEASURED AT SIX-MONTH POST-OPERATION VISIT AT 85 DEGREES, WITH A DIFFERENCE OF 12 DEGREES. REPORTEDLY, THE PATIENT HAD NO COMPLAINTS AT THE SIX-MONTH VISIT AND DID NOT REQUIRE A SECONDARY SURGICAL PROCEDURE. THE LENS REMAINED IMPLANTED. ADDITIONAL INFORMATION WAS RECEIVED AN IT WAS LEARNT THAT THE SAME IMPLANTED LENS WAS PREVIOUSLY MEASURED AT ONE-MONTH POST-OPERATION VISIT AT 87 DEGREES. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6426841 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗