TECNIS IOL ZCT225 (REF ZCT225U180)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC 1-PIECE 6.0MM 18.0D CYL2.25 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474552692), received between Aug 28, 2017 and Oct 28, 2020 — classified as 5 injuries.
The most frequently reported specific device problem is “Failure to Eject” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Failure to Eject1
- Inadequacy of Device Shape and/or Size1
- Unexpected Therapeutic Results1
Patient problems
- No Code Available4
- Capsular Bag Tear1
- Vitrectomy1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryOct 28, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AFTER THE TECNIS TORIC INTRAOCULAR LENS (IOL) WAS FULLY INSERTED, WHEN THE SURGEON WAS ROTATING THE LENS INTO POSITION, IT CUT THROUGH THE PATIENT'S CAPSULAR BAG. A VITRECTOMY WAS REQUIRED AND THE IOL WAS REMOVED AND REPLACED WITH A NON-JOHNSON AND JOHNSON LENS. REPORTEDLY, PATIENT HAS RECOVERED POST SURGERY. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: Capsular Bag Tear; Vitrectomy
MAUDE report 10745263 ↗InjuryJul 31, 2019Failure to Eject; Failure to Eject
IT WAS REPORTED ZCT225 18.0 DIOPTER INTRAOCULAR LENS (IOL) MODEL WAS STUCK IN THE CARTRIDGE AND IT WOULD NOT ADVANCE OR REMOVE. THERE WAS NO PATIENT CONTACT, THE PATIENT LEFT THE SURGERY CENTER WITHOUT HAVING A LENS INSERTED INTO THE PATIENT¿S OCULAR SINISTER (LEFT EYE), AND A SECOND SURGERY IS REQUIRED. IT WAS ALSO REPORTED OUTCOME SIGNIFICANTLY INTERFERES WITH ACTIVITIES OF DAILY LIFE. NO ADDITIONAL INFORMATION WAS PROVIDED TO JOHNSON & JOHNSON SURGICAL VISION.
Patient problems: No Code Available
MAUDE report 8848948 ↗InjuryFeb 14, 2019Unexpected Therapeutic Results; Unexpected Therapeutic Results
IT WAS REPORTED THAT AN ZCT225 18.0 DIOPTER INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE PATIENT'S LEFT EYE (OS) ON (B)(6) 2018. IT WAS LATER EXPLANTED ON (B)(6) 2019 DUE TO THE PATIENT HAVING A HYPEROPIC OUTCOME. THERE WAS NO INCISION ENLARGEMENT AND NO COMPLICATIONS REPORTED. THE REPLACEMENT LENS WAS THE SAME MODEL, BUT DIFFERENT DIOPTER OF 19.5. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 8338276 ↗InjuryAug 17, 2018Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size
IT WAS REPORTED THAT A TECNIS TORIC INTRAOCULAR LENS (MODEL ZCT225, +18.0 DIOPTER) WAS EXPLANTED FROM PATIENT¿S RIGHT EYE BECAUSE PATIENT WAS EXPERIENCING AN UNDESIRED REFRACTIVE ERROR. REPLACEMENT LENS WAS THE SAME MODEL, A LARGER DIOPTER OF +18.5. BEST CORRECTED VISUAL ACUITY: PRE-20/30 POST-20/20. NO FURTHER INFORMATION PROVIDED.
Patient problems: No Code Available
MAUDE report 7795223 ↗InjuryAug 28, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A TECNIS TORIC INTRAOCULAR LENS (IOL), MODEL ZCT225 18.0 DIOPTER, WAS EXPLANTED ON (B)(6) 2017. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 6825991 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page