TECNIS IOL ZCT300 (REF ZCT300U110)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC 1-PIECE 6.0MM 11.0D CYL3.00 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 05050474553149), received between Mar 23, 2017 and Apr 5, 2022 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Device Dislodged or Dislocated1
- Material Fragmentation1
- Unintended Movement1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Flashers1
- No Consequences Or Impact To Patient1
- Visual Disturbances1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2022Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) HAD AN ISSUE. ADDITIONAL INFORMATION RECEIVED REVEALED THAT THE LEADING HAPTIC OF THE INTRAOCULAR LENS (IOL) WAS CAUGHT BETWEEN THE PISTON AND OPTIC UPON ATTEMPTED INSERTION AND THE HAPTIC GOT PULLED OFF. THERE WAS CONTACT WITH PATIENT'S OPERATIVE EYE. ANOTHER LENS OF DIFFERENT MODEL (A 3-PIECE LENS) WAS PLACED IN THE SULCUS. NO OTHER INTERVENTION WAS REQUIRED. THE ORIGINAL LENS WAS DISCARDED. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14017726 ↗MalfunctionApr 5, 2022Break; Break
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) HAD AN ISSUE. ADDITIONAL INFORMATION RECEIVED REVEALED THAT THE TRAILING HAPTIC OF THE INTRAOCULAR LENS (IOL) WAS PINCHED IN THE NOSECONE UPON ATTEMPTED INSERTION AND THE HAPTIC GOT BENT AND FRACTURED. THERE WAS CONTACT WITH PATIENT'S EYE. ANOTHER LENS OF DIFFERENT MODEL (A 3-PIECE LENS) WAS PLACED IN THE SULCUS. NO OTHER INTERVENTION WAS REQUIRED. THE ORIGINAL LENS WAS DISCARDED. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14017670 ↗MalfunctionJul 10, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT A ZCT300 11.0 DIOPTER INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE PATIENT'S LEFT EYE (OS) ON (B)(6) 2017. THE LENS PLACED AT 14 DEGREES, WAS MEASURED AT 160 DEGREES AT THE PATIENT'S 6-MONTH FOLLOW UP VISIT ON (B)(6) 2018. THERE WERE NO PATIENT COMPLICATIONS AND/OR RELATED INJURY AND THE OUTCOME DOES NOT SIGNIFICANTLY INTERFERE WITH ACTIVITIES OF DAILY LIFE. REPORTEDLY, THE LENS REMAINS IMPLANTED AND NO IOL REPOSITIONING WAS PERFORMED OR PLANNED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7673174 ↗MalfunctionMar 23, 2017Unintended Movement; Unintended Movement
IT WAS REPORTED THAT THERE WAS A MISALIGNMENT OF 11 DEGREES BETWEEN OPERATIVE AND THE 4 MONTH POSTOPERATIVE VISIT. THE INTRAOCULAR LENS (IOL) WAS PLACED AT 76 DEGREES IN THE RIGHT EYE DURING THE INITIAL SURGERY ((B)(6) 2016) AND WAS MEASURED AT THE 4 MONTH VISIT (16 FEB 2017) TO BE AT 65 DEGREES, WITH A DIFFERENCE OF 11 DEGREES. THE PATIENT COMPLAINED OF FLASHES OF LIGHT AND HAZINESS IN THE RIGHT EYE. NO OTHER PATIENT COMPLICATIONS AND/OR RELATED INJURIES. THE IOL REMAINS IMPLANTED. NO REPOSITIONING WAS REQUIRED. NO ADDITIONAL INFORMATION WAS PROVIDED TO ABBOTT MEDICAL OPTICS.
Patient problems: Flashers; Visual Disturbances
MAUDE report 6426842 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page