TECNIS IOL ZCT300 (REF ZCT300U205)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC 1-PIECE 6.0MM 20.5D CYL3.00 · Class 3 · Implant
All models of TECNIS IOL (1343)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 05050474553330), received between Dec 5, 2016 and Jun 9, 2021 — classified as 6 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Unintended Movement” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem5
- Unintended Movement2
- Inadequacy of Device Shape and/or Size1
- Material Fragmentation1
Patient problems
- No Code Available6
- Blurred Vision2
- Capsular Bag Tear1
- Halo1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
- Vitrectomy1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 9, 2021Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) HAPTIC DETACHED INSIDE THE PATIENT'S EYE. THE LENS WAS REMOVED AND REPLACED WITH ANOTHER LENS OF SAME MODEL (SN (B)(4)). HOWEVER, THERE WAS NO INJURY AND THERE WAS NO INTERVENTION THAT WAS REQUIRED. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11971626 ↗InjurySep 30, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A ZCT300 20.5 DIOPTER INTRAOCULAR LENS (IOL) WAS INSERTED AND THEN REMOVED BECAUSE THE PATIENT'S CHAMBER WAS WEAK AND WOULD NOT HOLD THE LENS. A VITRECTOMY WAS REQUIRED. VIA FOLLOW-UP THE CUSTOMER SAID THAT THERE DIDN'T APPEAR TO BE ANYTHING WRONG WITH THE LENS. THE PATIENT HAS A WEAK ANATOMY. A BACKUP IOL WAS USED TO COMPLETE THE PROCEDURE. THE CUSTOMER LATER FOLLOWED-UP TO PROVIDE MORE DETAILED INFORMATION. THE LENS WAS INJECTED INTO THE CAPSULAR BAG. IT WAS DIFFICULT TO KEEP THE BAG OPEN WHEN INSERTING THE LENS. ADDITIONAL VISCOELASTIC WAS INJECTED AROUND THE LENS. EVEN WITH THIS, THE LENS SEEMED TO DRAG ON THE CAPSULE. THE IOL WAS INSERTED AND VISCOELASTIC WAS IRRIGATED AND IT WAS VERY DIFFICULT TO REMOVE BEHIND THE LENS. THE ANTERIOR CHAMBER WAS INJECTED WITH BALANCED SALT SOLUTION AND WHEN ROTATING THE IOL IT WAS NOTED THAT THE POSTERIOR CAPSULE WAS OPENED. THE DECISION WAS MADE TO REMOVE THE TORIC IOL AS THERE WAS NOT ENOUGH CAPSULAR SUPPORT FOR THE LENS. ADDITIONAL VISCOELASTIC WAS USED TO DEEPEN THE CHAMBER. MICRO SCISSORS AND GRASPERS WERE USED TO HOLD AND CUT THE LENS. THE LENS WAS REMOVED WITHOUT PROBLEMS. AN ANTERIOR MECHANICAL VITRECTOMY WAS DONE
Patient problems: Capsular Bag Tear; Vitrectomy
MAUDE report 9137901 ↗InjuryAug 20, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A ZCT300 INTRAOCULAR LENS (IOL) WAS EXPLANTED DUE TO UNEXPECTED POST-OP REFRACTION. AN INCISION ENLARGEMENT WAS PERFORMED BUT NO VITRECTOMY AND NO SUTURES. THE IOL WAS EXCHANGE FOR AN IOL OF A DIFFERENT MODEL AND DIOPTER. REQUESTS WERE MADE FOR ADDITIONAL INFORMATION BUT NO RESPONSE WAS RECEIVED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 8913569 ↗InjuryNov 5, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT TECNIS TORIC INTRAOCULAR LENS (MODEL ZCT300, +20.5 DIOPTER) WAS EXPLANTED FROM PATIENT¿S OPERATIVE EYE BECAUSE OF PATIENT EXPERIENCING BLURRY AND DOUBLE VISION. THERE WAS NO VITRECTOMY, NO SUTURES AND NO INCISION ENLARGEMENT PERFORMED. REPORTEDLY LENS WITH MODEL AAB00, +18.5 DIOPTER WAS USED AS REPLACEMENT FOR THE PATIENT. PATIENT HAD NO ISSUES AND NO PROBLEMS POST OPERATIVELY. NO FURTHER INFORMATION PROVIDED.
Patient problems: Blurred Vision; No Code Available
MAUDE report 8040638 ↗MalfunctionSep 28, 2018Unintended Movement; Unintended Movement
IT WAS REPORTED THAT MODEL ZCT300 TECNIS TORIC IOL (INTRAOCULAR LENS) WAS PLACED AT 90 DEGREES IN HER RIGHT EYE (OD) AND WAS MEASURED AT 103 DEGREES IN 6-MONTH STUDY VISIT. THERE IS NO IOL REPOSITIONING PLAN AT THIS TIME AS OUTCOME DID NOT SIGNIFICANTLY INTERFERE WITH ACTIVITIES OF DAILY LIFE. FURTHERMORE, THERE WAS NO PATIENT INJURY. PRODUCT WILL NOT BE RETURNED AS IT REMAINS IMPLANTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7918732 ↗InjuryApr 6, 2018Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size
IT WAS REPORTED THAT A TECNIS INTRAOCULAR LENS (MODEL ZCT300, +20.5 DIOPTER) WAS EXPLANTED FROM THE PATIENT'S OPERATIVE EYE IN A SECONDARY PROCEDURE. A LENS MODEL ZCT300, +18.5 DIOPTER WAS IMPLANTED AS A REPLACEMENT. NO INCISION ENLARGEMENT, NO VITRECTOMY WAS PERFORMED AND NO OTHER MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. THE PATIENT WAS REPORTED DOING GOOD WHEN DISCHARGED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 7402099 ↗InjuryMar 29, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A TORIC INTRAOCULAR LENS (IOL) WAS EXPLANTED IN A SECONDARY SURGICAL PROCEDURE FROM THE RIGHT EYE OF FEMALE PATIENT DUE TO RESIDUAL ASTIGMATISM. REPORTEDLY, THERE WAS NO INCISION ENLARGEMENT, NO VITRECTOMY WAS PERFORMED, NO SUTURES WERE USED AND NO PATIENT POST-OP INJURY WAS REPORTED. A DIFFERENT TORIC LENS WAS IMPLANTED, ZCT150 +21,0 DIOPTER. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 6444309 ↗InjuryFeb 6, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS EXPLANTED DUE TO MECHANICAL FAILURE. FURTHER INFORMATION WAS PROVIDED AND STATED THAT MECHANICAL FAILURE REFERS TO HALOS/GLARE AND BLURRY VISION AND THAT IT IS UNKNOWN IF IT'S DUE TO THE LENS OR DUE TO A PATIENT ISSUE. A VITRECTOMY WAS PERFORMED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Blurred Vision; Halo; No Code Available
MAUDE report 6306010 ↗MalfunctionDec 5, 2016Unintended Movement; Unintended Movement
IT WAS REPORTED THAT A TORIC INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE LEFT EYE OF A (B)(6) YEAR-OLD MALE PATIENT. THE LENS WAS PLACED AT 95 DEGREES AND IT WAS MEASURED AT 111 DEGREES AT THE SIX MONTH POST-OP VISIT, WITH A MISALIGNMENT OF 16 DEGREES. THE PATIENT WAS REPORTED COMPLAINING OF TIRED EYES, BUT THE VISUAL ACUITY WAS FINE. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Code Available
MAUDE report 6145499 ↗
FDA clearance and classification
The FDA regulates product code MJP (lens, intraocular, toric optics) under 21 CFR 886.3600 as a Class III device. 21 CFR 886.3600 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the TECNIS IOL ZCT300
Has the TECNIS IOL ZCT300 been recalled?
No FDA recall record in our data names this exact device identifier (DI 05050474553330), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the TECNIS IOL ZCT300?
The FDA's MAUDE database lists 9 adverse event reports for this device, received between Dec 5, 2016 and Jun 9, 2021. In those reports, the most common specific device problems are “Unintended Movement” (2), “Inadequacy of Device Shape and/or Size” (1) and “Material Fragmentation” (1); the most common patient problems are “Blurred Vision” (2), “Capsular Bag Tear” (1) and “Halo” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the TECNIS IOL ZCT300?
None of the reports are classified as deaths, 6 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the TECNIS IOL ZCT300 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the TECNIS IOL ZCT300, and is it still sold?
The FDA's device database lists Johnson & Johnson Surgical Vision, Inc. as the company responsible for it (brand TECNIS IOL, model ZCT300). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS42 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS34 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS31 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS31 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS28 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page