TECNIS IOL ZKB00 (REF ZKB00U0260)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS MF 1- PC 6.0MM 26.0D LOW ADD US · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474560208), received between Jan 31, 2018 and Jun 13, 2019 — classified as 3 injuries.

The most frequently reported specific device problem is “Inadequacy of Device Shape and/or Size” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Inadequacy of Device Shape and/or Size2
  • Device Dislodged or Dislocated1

Patient problems

  • No Code Available3
  • Blurred Vision1
  • Visual Disturbances1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 13, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) IMPLANTED IN THE PATIENT'S RIGHT EYE SHIFTED, AND THERE WAS A MYOPIC SHIFT. THE IOL WAS EXCHANGED WITH ANOTHER IOL OF THE SAME MODEL BUT .5 DIOPTER LOWER. THE PATIENT IS DOING WELL POST-EXCHANGE. THERE WAS NO ADDITIONAL INTERVENTION REQUIRED. ADDITIONAL INFORMATION REPORTED THE MYOPIC SHIFT WAS A RESULT OF THE LENS SHIFT AND THE PATIENT DID NOT HAVE ANY CONTRIBUTING MEDICAL HISTORY. NO ADDITIONAL INFORMATION WAS RECEIVED.

    Patient problems: No Code Available

    MAUDE report 8694388 ↗
  • InjurySep 26, 2018Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT THE TECNIS MULTIFOCAL INTRAOCULAR LENS (MODEL ZKB00, +26.0 DIOPTER) WAS EXPLANTED FROM THE PATIENT¿S RIGHT EYE. THE LENS WAS EXPLANTED DUE TO PATIENT EXPERIENCING MECHANICAL COMPLICATIONS; UNABLE TO SEE NEAR AND DISTANCE VISION CLEARLY. REPORTEDLY, THE LENS WAS REPLACED WITH THE SAME MODEL, A +27.0, A LARGER DIOPTER AND PATIENT HAS RECOVERED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Blurred Vision; No Code Available; Visual Disturbances

    MAUDE report 7912797 ↗
  • InjuryJan 31, 2018Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED THAT A TECNIS MULTIFOCAL INTRAOCULAR LENS (MODEL ZKB00 +26.0 DIOPTER) WAS EXPLANTED IN A SECONDARY PROCEDURE BECAUSE OF PATIENT COMPLAINING OF UNSATISFACTORY VISUAL OUTCOME. TECNIS MULTIFOCAL INTRAOCULAR LENS (MODEL ZKB00 +25.0 DIOPTER) WAS IMPLANTED AS THE REPLACEMENT LENS FOR THE PATIENT. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Code Available

    MAUDE report 7231911 ↗

Other LENS, MULTIFOCAL INTRAOCULAR devices

All LENS, MULTIFOCAL INTRAOCULAR devices →