SMARTLOAD GAB00 (REF GAB0000205)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · SMARTLOAD SENSAR 1PC CLEAR MONO 20.5D · Class 3
All models of SMARTLOAD (52)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474621794), received between Mar 12, 2025 and Apr 13, 2026 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Crack” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Crack2
- Break1
- Contamination1
- Device Difficult to Setup or Prepare1
- Material Fragmentation1
- Material Split, Cut or Torn1
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 13, 2026Crack; Material Fragmentation
IT WAS REPORTED THAT THE PLASTIC MATERIAL AT THE TIP OF THE INTRAOCULAR LENS (IOL) CARTRIDGE WAS FOUND TO BE DAMAGED AND HAD BROKEN OFF. THE MATERIAL WAS REMOVED BEFORE THE LENS WAS INSERTED, AND NO ADVERSE EFFECTS OR CLINICAL COMPLICATIONS WERE OBSERVED IN THE PATIENT. THE PROCEDURE WAS NOT DELAYED, NO ADDITIONAL INTERVENTIONS WERE REQUIRED, AND THE PATIENT FULLY RECOVERED WITH DAILY ACTIVITIES UNAFFECTED. ISSUE WAS OBSERVED DURING LENS IMPLANTATION. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24867159 ↗MalfunctionJul 21, 2025Contamination; Contamination
IT WAS REPORTED THAT DURING IMPLANTATION OF THE PRELOADED INTRAOCULAR LENS (IOL), A SMALL HAIR OR LINT WAS DISCOVERED. THE IOL WAS FULLY IMPLANTED. THE FOREIGN MATERIAL WAS REMOVED IMMEDIATELY AND THE PATIENT HAS FULLY RECOVERED. THROUGH FOLLOW UP, WE LEARNED THAT THE FOREIGN MATERIAL WAS DISCARDED. NO FURTHER DETAILS WERE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22561799 ↗MalfunctionApr 30, 2025Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS DEFECTIVE, IT WAS TORN. NO FURTHER DETAILS WERE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21936791 ↗MalfunctionMar 18, 2025Crack; Mechanical Jam; Crack; Mechanical Jam
IT WAS REPORTED THAT DURING THE IMPLANTATION OF THE INTRAOCULAR LENS (IOL) THE LENS BECAME STUCK IN THE CARTRIDGE, CAUSING THE CARTRIDGE TO BREAK AND MAKING IT IMPOSSIBLE TO EXTRACT THE LENS. THE IOL WAS REPLACED WITH A BACK UP LENS. THROUGH FOLLOW UP, WE LEARNED THAT THE DAMAGE WAS ON THE TIP OF THE CARTRIDGE. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21638901 ↗MalfunctionMar 12, 2025Break; Device Difficult to Setup or Prepare; Break; Device Difficult to Setup or Prepare
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) BROKE WHILE USING THE APPROPRIATE INJECTOR. THE PROCEDURE WAS THE SAME AS ALWAYS, FOLLOWING THE SPECIALIST'S INSTRUCTIONS. WHEN PUSHING THE LENS SLOWLY INTO THE CARTRIDGE, A GREATER FRICTION THAN USUAL WAS OBSERVED. ALTHOUGH THE SURGEON ATTEMPTED TO RECOVER THE LENS, IT WAS IRREVERSIBLY DAMAGED; THEREFORE, THE IOL WAS REPLACED TO COMPLETE THE SURGERY. NO FURTHER INFORMATION WAS RECEIVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21590177 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page