TECNIS SIMPLICITY DCB00 (REF DCB0000280)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS SMPLCTY TECNIS 1PC CLR MONO 28.0D · Class 3 · Implant

All models of TECNIS SIMPLICITY (112)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05050474636248), received between Jun 30, 2023 and Dec 8, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Crack2
  • Failure to Fold1
  • Material Fragmentation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 8, 2025Break; Break

    IT WAS REPORTED THAT WHEN INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE EYE AND WHILE DOCTOR WAS ADJUSTING AND POSITIONING THE HAPTIC, THE HAPTIC BROKE. IOL WAS REMOVED AND REPLACED. SURGERY COMPLETED SUCCESSFULLY. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23751111 ↗
  • MalfunctionAug 22, 2025Crack; Crack

    IT WAS REPORTED THAT DURING IMPLANTATION OF THE PRELOADED MONOFOCAL INTRAOCULAR LENS (IOL) THE IOL WAS TRACKING ON THE SIDE OF THE TIP. THE CARTRIDGE TIP WAS IN CONTACT WITH THE EYE BUT NO PATIENT INJURY WAS REPORTED. NO MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. NO CONCERNS WERE RAISED REGARDING PATIENT OUTCOME. NO FURTHER INFORMATION AS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22877833 ↗
  • MalfunctionJan 15, 2025Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT THE PRELOADED MONOFOCAL INTRAOCULAR LENS (IOL) WAS FULLY INSERTED WHEN IT WAS NOTICED THAT THE HAPTIC WAS CAUGHT IN THE INJECTOR AND BECAME DISLOCATED. THE IOL WAS REMOVED WITH FORCEPS, AND THE PROCEDURE WAS COMPLETED WITH A BACKUP LENS. THERE WAS NO PATIENT INJURY REPORTED. NO ADDITIONAL INFORMATION WAS RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21162023 ↗
  • MalfunctionDec 21, 2023Break; Failure to Fold; Break; Failure to Fold

    IT WAS REPORTED BY THE SURGEON THAT THE LEADING HAPTIC OF THE INTRAOCULAR LENS DID NOT COME OUT OF THE PRELOADED CARTRIDGE CORRECTLY, AND WAS DEFECTIVE. LENS WAS PARTIALLY INSERTED IN THE PATIENTS LEFT EYE. A NEW LENS HAD TO BE OPENED AND IMPLANTED. THE ISSUE WAS IDENTIFIED DURING IMPLANTATION. DIRECTIONS FOR USE WERE FOLLOWED. THERE WAS A DELAY IN THE PROCEDURE. PATIENT OUTCOME WAS UNKNOWN. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18372660 ↗
  • MalfunctionNov 20, 2023Crack; Crack

    IT WAS REPORTED THE DCB00 MODEL INTRAOCULAR LENS (IOL) INSERTER CRACKED WHILE IN THE PATIENT'S OPERATIVE EYE. WHEN THE DOCTOR WENT TO IMPLANT THE IOL, HE SAW THAT THE TIP WAS STRESSED, LOOKED LIKE IT WAS GOING TO CRACK. THE DOCTOR STATED HE HAS SEEN THIS BEFORE, SO HE DECIDED TO NOT FULLY ADVANCE THE LENS AND USE A NEW ONE. HE FULLY THE ADVANCED THE DEFECTED INSERTER OUTSIDE THE PATIENTS EYE AND THE TIP CRACKED. THE DOCTOR DID THIS JUST TO CONFIRM WHAT HE THOUGHT WAS GOING TO HAPPEN. THERE WAS NO ADDITIONAL INTERVENTION REQUIRED. PATIENT STATUS POST-PROCEDURE WAS REPORTED AS DOING WELL. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18179066 ↗
  • MalfunctionJun 30, 2023Break; Break

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) BROKE DURING THE IMPLANTATION. THE LENS CAME OUT WITH A BROKEN PROXIMAL HAPTIC FROM THE INJECTOR. THE IOL WAS REMOVED DURING THE SAME PROCEDURE. THROUGH FOLLOW UP WE LEARNED THAT A NON-JOHNSON AND JOHNSON LENS WAS IMPLANTED SUCCESSFULLY. NO ADDITIONAL INFORMATION WAS RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17243873 ↗

Other intraocular lens devices