TECNIS IOL ZCU150 (REF ZCU150U195)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC II 1-PC 19.5D CYL1.50 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 05050474657786), received between Nov 4, 2020 and Sep 22, 2021 — classified as 3 injuries, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Device Dislodged or Dislocated1
- Smoking1
- Unstable1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Blurred Vision1
- Capsular Bag Tear1
- No Code Available1
- Vitrectomy1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjurySep 22, 2021Break; Break
IT WAS REPORTED THAT A DEFECT IN THE OPTIC OF THE LENS WAS NOTED ONCE THE LENS WAS INSERTED IN THE PATIENT¿S EYE. A LARGER INCISION WAS MADE TO CUT AND REMOVE THE DAMAGE LENS. THEN A BACK UP LENS WAS USED AND INCISION WAS CLOSED WITH SUTURE. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12511112 ↗MalfunctionFeb 5, 2021Unstable; Unstable
IT WAS REPORTED THAT A CLINICAL STUDY PATIENT WAS IMPLANTED AN INTRAOCULAR LENS (IOL). IOL WAS IMPLANTED AT 61 DEGREES ON OP DAY. AT DAY 1, IT WAS NOTED THAT THE IOL WAS 058 DEGREES. AT WEEK 1, IOL WAS NOTED TO BE AT 047 DEGREES. IT WAS STATED THAT THE OUTCOME DOES NOT SIGNIFICANTLY INTERFERE WITH THE PATIENT¿S DAILY LIFE. NEVERTHELESS, ADDITIONAL INFORMATION WAS RECEIVED THAT AT 1-WEEK POSTOPERATIVE IOL AXIS WAS ESTIMATED TO BE RIGHT EYE (OD) AT 047 DEGREES. THE UNCORRECTED VISUAL ACUITY OD AT THE 1-WEEK POSTOPERATIVE (PO) VISIT: 20/25. MANIFEST REFRACTION OD: +0.75 -0.50 X 042. BEST-CORRECTED VISUAL ACUITY OD: 20/25. SUBJECT REPORTED NO VISUAL SYMPTOM COMPLAINTS THIS VISIT. THERE WAS NO SURGICAL INTERVENTION PLANNED AT THIS TIME. IT WAS LEARNED IN FURTHER FOLLOW-UP THAT THE COMPLAINT WAS BASED UPON A SUBJECTIVE ESTIMATE MADE BY THE INVESTIGATOR FROM A SLIT-LAMP MEASUREMENT. FOR THIS STUDY, CLINICAL HAS ALSO BEEN DOING INDEPENDENT ANALYSIS OF THE IOL PHOTOS TAKEN AT EACH VISIT. THESE ARE OBJECTIVE MEASUREMENTS OF THE ACTUAL IOL AXIS. BASED ON THIS OBJECTIVE MEASUREMENT, THE ACTUAL AMOUNT OF IOL ROTATION FOR THE SUBJECT BELOW IS LESS THAN 03 DEGREES. THERE IS STILL NO SURGICAL INTE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11290038 ↗InjuryNov 18, 2020Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THERE WAS PATIENT CONTACT WITH THE INTRAOCULAR LENS (IOL), AND THERE WAS CAPSULE TEAR. THE IOL COULD NOT BE POSITIONED WELL AFTER TRYING TO IMPLANT. SUSPECT LENS THEN WAS REPLACED WITH A DIFFERENT LENS MODEL, ZA9003. A VITRECTOMY WAS PERFORMED, HOWEVER, THERE WAS NO INCISION ENLARGEMENT, OR SUTURES REQUIRED. NO REPORTED PATIENT POST-OP INJURY. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Capsular Bag Tear; Vitrectomy
MAUDE report 10858101 ↗InjuryNov 4, 2020Smoking; Smoking
IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM PATIENT RIGHT EYE DUE TO BLURRY VISION POST CATARACT AS THE POWER OF THE IOL WAS INCORRECT FROM WHAT WAS RECORDED. THE OPTICAL RESPONSE ANALYZER (ORA) MACHINE WAS USED DURING SURGERY, SO THE CONTACT STATED THEY ASSUME THAT IT WAS A POWER CALCULATION ISSUE THAT OCCURRED DURING SURGERY. LENS WAS REPLACED ANOTHER LENS OF THE SAME MODEL, BUT LOWER DIOPTER, 18.5. NO FURTHER INFORMATION PROVIDED.
Patient problems: Blurred Vision; No Code Available
MAUDE report 10783025 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page