TECNIS IOL ZCU150 (REF ZCU150U245)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC II 1-PC 24.5D CYL1.50 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474657885), received between Jan 27, 2022 and Mar 4, 2025 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Material Fragmentation1
Patient problems
- Visual Impairment3
- Blurred Vision1
- No Clinical Signs, Symptoms or Conditions1
- Visual Disturbances1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryMar 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) WAS EXPLANTED DUE TO REFRACTIVE SURPRISE. FOLLOW-UP WAS PERFORMED REGARDING THIS EVENT BUT NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Visual Impairment
MAUDE report 21521068 ↗InjuryMar 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE JOHNSON AND JOHNSON (JNJ) PRELOADED INTRAOCULAR LENS (IOL) WAS EXPLANTED. THE PATIENT COMPLAINED OF BLURRED NEAR VISION OS AT POST-OP ON (B)(6) 2024. TARGET REFRACTION WAS -1.50. POST-OP REFRACTION ON (B)(6) 2024 WAS -2.50+0.50X178. THE PATIENT EXPRESSED DESIRE FOR AN IOL EXCHANGE PROCEDURE FOR BETTER NEAR VISION. THE PATIENT ALSO EXPERIENCED GLARE AND NEGATIVE DYSPHOTOPSIA. THE IOL WAS EXPLANTED AND REPLACED WITH ANOTHER JNJ TORIC LENS. THE SERIAL NUMBER IS UNKNOWN. THE PATIENT IS DOING WELL. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 18876755 ↗InjuryJan 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S LEFT EYE, IN A SECONDARY PROCEDURE DUE TO WRONG POWER. IOL WAS REPLACED WITH THE SAME MODEL LENS 1.50 POWER SIZE. THERE IS NO PATIENT INJURY. THERE WAS NO MEDICAL/SURGICAL INTERVENTION REQUIRED. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Visual Impairment
MAUDE report 18531794 ↗MalfunctionOct 13, 2023Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE TECNIS TORIC INTRAOCULAR LENS HAPTIC WAS BROKE OFF, PATIENT CONTACT AND NO PATIENT HARM. BACKUP LENS WAS USED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17931442 ↗InjuryJan 27, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THE INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT¿S OCULAR SINISTER (LEFT EYE) IN A SEPARATE SURGICAL PROCEDURE DUE TO COMPLAINTS OF MYOPIC DRIFT. THE IOL WAS REPLACED WITH A DIFFERENT MODEL IOL WITH A DIFFERENT DIOPTER SIZE, LENS MODEL ZCU225 22.0 DIOPTER. THERE WAS NO MEDICAL OR SURGICAL INTERVENTION REQUIRED OUTSIDE OF THE REGULAR STANDARD OF CARE. PATIENT STATUS POST-LENS EXCHANGE WAS REPORTED AS STILL SOME BLURRINESS. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Visual Impairment
MAUDE report 13370603 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page