TECNIS IOL ZCU150 (REF ZCU150U250)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS TORIC II 1-PC 25.0D CYL1.50 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05050474657892), received between Jan 8, 2021 and Jul 3, 2024 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Blurred Vision2
- Discomfort1
- Visual Impairment1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AFTER THE NON-PRELOADED TORIC INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE PATIENT'S RIGHT EYE, THE PATIENT'S DISTANCE VISION WAS BLURRY. THE PATIENT THOUGHT THE LENS WOULD IMPROVE DISTANCE VISION, BUT INSTEAD THE PATIENT IS ABLE TO SEE WELL CLOSE, UP TO TWO FEET, BUT DISTANCE IS BLURRY. THE PATIENT IS DISSATISFIED. AT THE POST-OPERATIVE VISIT ON (B)(6) 2024, THE PATIENT WAS TOLD THAT THE LENS WAS PLACED CORRECTLY AND IF UNHAPPY, LASIK, PRK OR A PIGGYBACK LENS COULD BE PERFORMED. THE PATIENT HAS GLAUCOMA. THE PATIENT IS SCHEDULED TO SEE THE DOCTOR AGAIN IN TWO WEEKS AND DOES NOT WANT THE LEFT EYE CATARACT SURGERY PERFORMED UNTIL THIS ISSUE CLEARS UP. THE PATIENT WILL BE SEEKING A SECOND OPINION. THROUGH FOLLOW-UP, IT WAS LEARNED THAT THE ISSUE WAS NOTICED TWO DAYS AFTER SURGERY; NEAR VISION WAS GOOD BUT ALL ELSE BLURRY. THIS IS STILL THE SITUATION AT ALMOST ONE MONTH, BUT THE DOCTOR ADVISED THAT SOME PEOPLE TAKE LONGER TO ADAPT. THE PATIENT CANNOT DRIVE SAFELY OR GROCERY SHOP UNLESS THE RIGHT EYE IS CLOSED, AS EVEN MID RANGE VISION IS NOT AS GOOD AS BEFORE. THE PATIENT CANNOT PLAY CROQUET. THE PATIENT IS UNABLE TO WORK ON THE COMPUTER UNLESS TEN INCHES FROM IT.
Patient problems: Blurred Vision; Discomfort
MAUDE report 19671770 ↗InjuryJan 8, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A TECNIS TORIC INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S EYE DURING SECONDARY PROCEDURE. COMPLAINT DESCRIPTION, ANISOMETROPIA, DEBILITATING. ORIGINALLY, THE SURGEON TARGETED NEAR INTERMEDIATE VISION CORRECTION. PATIENT WAS NOT SATISFIED WITH THE REFRACTIVE OUTCOME WITH MEASURED OF RESIDUAL ASTIGMATISM. AFTER MANY VISITS, AND WAS REFERRED TO A CORNEAL SPECIALIST, A LENS EXCHANGE WAS REQUIRED. THE REPLACEMENT LENS IS A STANDARD MONOFOCAL LENS AND PATIENT IS HAPPY WITH THE SURGERY OUTCOME. PRE-OPERATIVE VISUAL ACUITY (VA) WAS 20/70 NEAR, AND POST-OPERATIVE VA IS 20/40 NEAR. AT EXPLANT THE INCISION WAS ENLARGED TO REMOVE THE LENS AND SUTURES WERE REQUIRED. THE EXPLANTED LENS WAS DISCARDED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: Blurred Vision; Visual Impairment
MAUDE report 11143480 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page