TECNIS SIMPLICITY DIB00 (REF DIB00U0260)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS SIMPLICITY TECNIS EYHANCE U 26.0D · Class 3 · Implant

All models of TECNIS SIMPLICITY (112)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474731882), received between Jul 10, 2024 and Jan 9, 2026 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Visual Impairment1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 9, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PRELOADED MONOFOCAL INTRAOCULAR LENS (IOL), MODEL DIB00, WAS IMPLANTED IN THE PATIENT¿S LEFT EYE. POSTOPERATIVELY, THE PATIENT WAS MORE MYOPIC THAN ANTICIPATED. A SECONDARY PROCEDURE WAS PERFORMED TO EXPLANT THE ORIGINAL LENS AND REPLACE IT WITH THE SAME MODEL OF LOWER DIOPTER (+23.5D). THE PROCEDURE DID NOT REQUIRE INCISION ENLARGEMENT, UNPLANNED VITRECTOMY, OR SUTURES. THE PATIENT REQUIRED NO ADDITIONAL MEDICAL ATTENTION OR MEDICATIONS BEYOND STANDARD CARE. THE PATIENT OUT COME WAS NOT PROVIDED. NO ADDITIONAL INFORMATION WAS PROVIDED. THE PATIENT HAD BILATERAL LENS IMPLANTATION. THIS REPORT IS FOR THE PATIENT'S LEFT EYE. A SEPARATE REPORT WILL BE SUBMITTED FOR THE RIGHT EYE.

    Patient problems: Visual Impairment

    MAUDE report 24029339 ↗
  • MalfunctionAug 22, 2024Break; Break

    IT WAS REPORTED THE PRE-LOADED DIB00 MODEL INTRAOCULAR LENS (IOL) USED DURING 31-JUL-2024 SURGERY WAS DEFECTIVE. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20037402 ↗
  • MalfunctionJul 10, 2024Break; Break

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS CURLED AT THE END. THE CARTRIDGE TIP ONLY HAD PATIENT CONTACT. BACK UP LENS WAS USED TO COMPLETE THE PROCEDURE. FROM ADDITIONAL INFORMATION IT WAS LEARNT THAT THE LENS CURLED UP AND SPLIT THROUGH THE TIP OF THE CARTRIDGE. THE ISSUE WAS NOTICED DURING THE IMPLANTATION/APPLICATION. THE PROCEDURE WAS COMPLETED WITH SAME MODEL LENS WITH SAME DIOPTER. THERE WAS NO PATIENT INJURY. BALANCED SALT SOLUTION (BSS) WAS USED AS A CARTRIDGE LUBRICANT. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19712233 ↗

Other intraocular lens devices

All intraocular lens devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page