TECNIS IOL DIU150 (REF DIU150U255)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 25.5D CYL1.50 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05050474746657), received between Jan 26, 2023 and Dec 10, 2025 — classified as 2 injuries, 4 malfunctions.
The most frequently reported specific device problem is “Inaccurate Delivery” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Inaccurate Delivery3
- Break2
- Adverse Event Without Identified Device or Use Problem1
- Application Program Problem: Dose Calculation Error1
- Crack1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Eye Injury2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Discomfort1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryDec 10, 2025Application Program Problem: Dose Calculation Error; Application Program Problem: Dose Calculation Error
IT WAS REPORTED BY THE CUSTOMER THAT THE PRELOADED MONOFOCAL INTRAOCULAR LENS (IOL), MODEL DIU150 WAS IMPLANTED INTO THE PATIENT'S RIGHT EYE (OD). INCORRECT DIOPTER SELECTED, RESULTING IN POOR DISTANCE VISION AND PATIENT DISSATISFACTION. LOCATION OF IMPLANT FOR THE OD AT 20 DEGREES. LENS WAS LATER EXPLANTED DURING A SECONDARY SURGICAL PROCEDURE. THE PATIENT OUTCOME IS UNKNOWN/NOT PROVIDED. THE EXPLANTED LENS WAS NOT KEPT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Discomfort
MAUDE report 23765064 ↗InjuryDec 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PRE-LOADED DIU150 MODEL INTRAOCULAR LENS (IOL) WAS REPORTED TO HAVE BEEN IMPLANTED IN THE PATIENT'S EYE. THE IOL WAS EXPLANTED AND REPLACED WITH A DIB00 23.0 DIOPTER IOL THAT WAS IMPLANTED IN THE PATIENT¿S OCULAR DEXTER (RIGHT EYE). PATIENT VISUAL ACUITY POST-LENS EXCHANGE WAS REPORTED AS 20/40. THE SUSPECT IOL IS NOT AVAILABLE FOR RETURN AS IT WAS DISCARDED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Eye Injury
MAUDE report 20873482 ↗MalfunctionOct 18, 2024Crack; Crack
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) CARTRIDGE BROKE DURING LENS INJECTION. THE SURGEON USED BACKUP LENSES AND THE CARTRIDGE TIP CAME INTO CONTACT WITH THE PATIENT. NO INJURIES OR MEDICAL INTERVENTIONS OCCURRED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20482383 ↗MalfunctionJan 26, 2023Inaccurate Delivery; Inaccurate Delivery
IT WAS REPORTED THAT THE SURGEON WAS ABLE TO MANIPULATE THE PRELOADED INTRAOCULAR LENS (IOL) HAPTICS WITH SURGICAL INSTRUMENTS TO ENSURE THE LENS WAS SAFELY IMPLANTED IN THE RIGHT EYE. THERE WAS NO DAMAGE OR ISSUE WITH THE LENS OR HAPTIC DURING INSERTION. THERE WAS NO ISSUE WITH THE LENS OR PATIENT AFTER THE LENS WAS IMPLANTED. THE PATIENT HAS NO COMPLICATIONS POST-OPERATIVELY AND HAS GOOD OUTCOMES. THERE ARE NO PLANNED INTERVENTIONS. THE LENS REMAINS IMPLANTED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16247671 ↗MalfunctionJan 26, 2023Break; Inaccurate Delivery; Break; Inaccurate Delivery
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) TRAILING HAPTIC GOT STUCK IN THE CARTRIDGE, SCRUNCHING IT, WHILE BEING INJECTED IN THE RIGHT EYE. THE LENS WAS FULLY INSERTED AND THEN REMOVED AND REPLACED IN THE SAME PROCEDURE. NO ADDITIONAL SURGICAL MANEUVERS WERE REQUIRED. WHEN THE LENS WAS REMOVED THERE WAS MINOR INJURY TO THE IRIS, HOWEVER NO SURGICAL OR MEDICAL INTERVENTION WAS REQUIRED. ANOTHER JOHNSON AND JOHNSON IOL WAS IMPLANTED AS REPLACEMENT (SAME MODEL AND DIOPTER). THE INCISION WAS ENLARGED. THE LENS IS NOT AVAILABLE FOR RETURN AND EVALUATION. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Eye Injury
MAUDE report 16247601 ↗MalfunctionJan 26, 2023Break; Inaccurate Delivery; Break; Inaccurate Delivery
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) TRAILING HAPTIC GOT STUCK IN THE CARTRIDGE, SCRUNCHING IT, WHILE BEING INJECTED IN THE RIGHT EYE. THE LENS WAS PARTIALLY INSERTED AND THEN REMOVED. NO ADDITIONAL SURGICAL MANEUVERS WERE REQUIRED. A BACK-UP LENS WAS USED (SAME MODEL AND DIOPTER). THE LENS IS NOT AVAILABLE FOR RETURN AND EVALUATION. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16247557 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page