TECNIS IOL DIU225 (REF DIU225U185)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 18.5D CYL2.25 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474747104), received between Jun 14, 2021 and Aug 25, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Difficult to Fold, Unfold or Collapse2
- Device Contaminated During Manufacture or Shipping1
- Inaccurate Delivery1
- Material Fragmentation1
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 25, 2025Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE HAPTIC OF THE TORIC PRELOADED INTRAOCULAR LENS WAS OBSERVED TO BE DETACHED UNDER THE MICROSCOPE AFTER IT WAS INSERTED AND WAS SUBSEQUENTLY REMOVED. IT WAS BELIEVED TO BE LEAD HAPTIC. THERE WAS NO PATIENT INJURY AND NO OTHER MEDICAL OR SURGICAL INTERVENTIONS REQUIRED. PATIENT IS DOING FINE POST-PROCEDURE. THROUGH FOLLOW UP, IT WAS LEARNT THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A BACKUP J&J LENS OF SAME MODEL AND DIOPTER. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22891815 ↗MalfunctionJan 21, 2025Break; Mechanical Jam; Break; Mechanical Jam
THE PRE-LOADED DIU225 MODEL INTRAOCULAR LENS (IOL) WAS REPORTED TO BE DIFFICULT TO DEPLOY AND CAME OUT OF THE DEVICE DAMAGED, CRUMBLED UP. THE IOL WAS ALSO STUCK IN THE CARTRIDGE. THERE WAS NO PATIENT CONTACT WITH THE IOL AND THERE WAS NO PATIENT INJURY. THE PROCEDURE WAS COMPLETED USING A BACK-UP LENS THAT WAS IMPLANTED IN THE PATIENT¿S OCULAR SINISTER (LEFT EYE). PATIENT PROGNOSIS POST-PROCEDURE WAS REPORTED AS FINE. PROVISC WAS USED AT ROOM TEMPERATURE AND THERE WAS NO DELAY BETWEEN PREP AND HAND-OFF TO THE DOCTOR. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21203026 ↗MalfunctionSep 1, 2023Difficult to Fold, Unfold or Collapse; Difficult to Fold, Unfold or Collapse
IT WAS REPORTED THAT THE TECNIS EYHANCE TORIC SIMPLICITY INTRAOCULAR LENS TRAILING HAPTIC WAS TRAPPED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17673299 ↗MalfunctionNov 15, 2021Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) HAS FOREIGN MATERIAL ON IT. THERE WAS NO OTHER INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12814119 ↗MalfunctionJun 14, 2021Break; Difficult to Fold, Unfold or Collapse; Inaccurate Delivery; Break; Difficult to Fold, Unfold or Collapse; Inaccurate Delivery
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) HAD A DEPLOYING ISSUE THAT THE TRAILING HAPTIC WAS STICKING OUT OF WOUND AFTER IT WAS INSERTED INTO PATIENT'S EYE. THE TRAILING HAPTIC WOULD NOT TUCK IN AND THE SURGEON THOUGHT THERE WAS A BARB IN THE CARTRIDGE THAT WOULD HAVE IMPEDED IT TUCKING IN. THE SURGEON USED A SECOND INSTRUMENT TO DIAL THE LENS INTO THE BAG AND IT REMAINS IMPLANTED. THE DOCTOR ASKED IF THERE WAS A BARB IN THE CARTRIDGE THAT COULD HAVE IMPEDED IT TUCKING IN. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11995500 ↗
Other LENS, INTRAOCULAR, TORIC OPTICS devices
- TECNIS IOL ZCT150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS1 recall7 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS43 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS36 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS32 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS30 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS29 reports
- Clareon CNWTT0Alcon Laboratories, Inc. · LENS, INTRAOCULAR, TORIC OPTICS21 reports
- TECNIS IOL DIU150Johnson & Johnson Surgical Vision, Inc. · LENS, INTRAOCULAR, TORIC OPTICS19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page