TECNIS IOL DIU225 (REF DIU225U220)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 22.0D CYL2.25 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474747173), received between Mar 13, 2023 and Jan 30, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Break1
  • Ejection Problem1
  • Scratched Material1
  • Unstable1

Patient problems

  • Blurred Vision2
  • No Clinical Signs, Symptoms or Conditions2
  • Visual Impairment2
  • Visual Disturbances1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 30, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A SINGLE-PIECE PRELOADED TORIC INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT¿S LEFT EYE DUE TO NEGATIVE DYSPHOTOPSIA. AFTER IMPLANTATION, THE PATIENT EXPERIENCED SYMPTOMS THAT WERE DESCRIBED AS SHADOWS AND FLASHES FROM THE LEFT EYE RADIATING TO THE RIGHT EYE. THE SYMPTOMS PERSISTED FOR APPROXIMATELY THREE MONTHS. THE ORIGINAL LENS WAS SUBSEQUENTLY EXPLANTED DURING A SECONDARY SURGERY AND REPLACED WITH A NON¿JOHNSON & JOHNSON IOL WITH A 22.0-DIOPTER POWER. NO UNPLANNED SURGICAL INTERVENTIONS, SUCH AS INCISION ENLARGEMENT, SUTURES, OR VITRECTOMY, WERE REQUIRED. NO DELAY IN THE PROCEDURE. IT IS UNKNOWN IF ANY MEDICATION WAS PRESCRIBED THAT WAS OUTSIDE OF THE STANDARD OF CARE. DIRECTIONS FOR USE WAS FOLLOWED. THE PATIENT HAS FULLY RECOVERED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Visual Disturbances

    MAUDE report 24227810 ↗
  • InjuryDec 23, 2025Unstable; Unstable

    IT WAS REPORTED THAT A CASE OF MYOPIC SURPRISE OCCURRED AFTER CATARACT SURGERY IN A PATIENT WITH A HISTORY OF LASER-ASSISTED IN SITU KERATOMILEUSIS (LASIK). AFTER DEVICE IMPLANTATION, THE PATIENT EXPERIENCED PERSISTENT BLURRY DISTANCE VISION, WITH POST-OPERATIVE REFRACTION SETTLING AT APPROXIMATELY -1.50, WHICH SIGNIFICANTLY IMPACTED PATIENT'S ABILITY TO SEE WELL. PRE-OPERATIVE: REFRACTION +1.00 +1.00 X 10; BEST SPECTACLE CORRECTED VISUAL ACUITY (BSCVA): 20/30. POST-OPERATIVE: REFRACTION -1.50 +0.50 X 165; BSCVA 20/70. INTENDED TARGET: PLANO SPHERE; INTENDED AXIS 180; ACTUAL POST-OPERATIVE AXIS 165 THE PRELOADED MONOFOCAL TORIC INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S RIGHT EYE IN A SECONDARY SURGICAL PROCEDURE BECAUSE OF THE UNEXPECTED REFRACTIVE OUTCOME; THE DEVICE WAS NOT REPLACED DURING THAT PROCEDURE. A REPLACEMENT WAS SCHEDULED FOR (B)(6) 2025. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 23885598 ↗
  • MalfunctionApr 15, 2024Scratched Material; Scratched Material

    IT WAS REPORTED THAT THE JOHNSON AND JOHNSON(JNJ) INTRAOCULAR LENS (IOL) HAD A SCRATCH. AFTER THE SURGEON INSERTED AND POSITIONED THE LENS THEY NOTICED IN THE MIDDLE OF THE LENS WAS A SCRATCH. THE DOCTOR CUT THE LENS OUT AND REPLACED IT WITH ANOTHER ONE OF THE SAME MODEL. THERE WERE NO COMPLICATIONS SUCH AS A CAPSULE TEAR, VITRECTOMY, SUTURES OR INCISION ENLARGEMENT. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19106979 ↗
  • MalfunctionMar 5, 2024Break; Ejection Problem; Break; Ejection Problem

    IT WAS REPORTED THAT THE PRELOADED TORIC INTRAOCULAR LENS (IOL) HAPTIC STARTED TO SHEAR WHILE BEING INSERTED. THE LENS WAS PARTIALLY INSERTED. IT IS UNKNOWN IF ANY RESISTANCE WAS FELT WHEN ADVANCING THE LENS. THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING A BACK-UP LENS (SAME MODEL AND DIOPTER). IT IS UNKNOWN IF THE ISSUE WAS RELATED TO USE ERROR. THERE WAS NO PATIENT INJURY. NO MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. THERE ARE NO PLANNED INTERVENTIONS. THE PATIENT OUTCOME WAS SATISFACTORY. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18838179 ↗
  • InjuryMar 13, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) DID NOT GIVE ENOUGH NEAR VISION WITHOUT GLASSES DESPITE TARGET -1-25. PROBLEM OCCURRED AT ALL TIMES POST-IMPLANT. VISUAL ACUITY (VA) PRE-OPERATIVE (OP): 20/20 GLARE TO 20/40, POST-OP VA: 20/20. THE PATIENT NEEDED LENS EXCHANGE TO A MULTIFOCAL LENS. THERE WAS INCISION ENLARGEMENT, BUT NO VITRECTOMY, NO SUTURES. STANDARD POST-OP MEDS WERE GIVEN. REPORTEDLY, THE PATIENT HAD CATARACT SURGERY ON THE RIGHT EYE (OD). THE DOCTOR DID THE SURGERY WITH AN EYHANCE TORIC. AT PATIENT'S 1 WEEK APPOINTMENT, IT IS NOTED ¿PATIENT NOT HAPPY WITH HER VISION. SHE SAYS HER VISION IS VERY BLURRY DISTANCE AND NEAR OD. OS (LEFT EYE) IS STILL BLURRY. PATIENT WANTS TO WAIT UNTIL OD IS BETTER BEFORE PROCEEDING WITH OS SURGERY.¿ PATIENT HAS HAD NUMEROUS VISITS AND HAS NOT BEEN HAPPY WITH HER VISION. THE PATIENT CAME BACK AND SAW THE DOCTOR AND THEY DISCUSSED DOING AN IOL EXCHANGE. EXPLANT WAS REPLACED WITH A NON-JOHNSON AND JOHNSON IOL. THE PRODUCT IS NOT AVAILABLE FOR RETURN. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 16530288 ↗

Other LENS, INTRAOCULAR, TORIC OPTICS devices

All LENS, INTRAOCULAR, TORIC OPTICS devices →