TECNIS IOL DIU300 (REF DIU300U130)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 13.0D CYL3.00 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474747586), received between Jun 21, 2022 and Apr 21, 2026 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Device Difficult to Setup or Prepare1
  • Ejection Problem1
  • Material Fragmentation1
  • Scratched Material1

Patient problems

  • Blurred Vision1
  • Corneal Abrasion1
  • No Clinical Signs, Symptoms or Conditions1
  • Visual Impairment1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 21, 2026Material Fragmentation; Device Difficult to Setup or Prepare; Ejection Problem

    THE FOLLOWING WAS REPORTED REGARDING THE JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL). UPON INSERTING THE CARTRIDGE INTO THE CLEAR CORNEAL INCISION (CCI) WHILE ADVANCING THE LENS, THE FIRST PART OF THE IOL ENTERED THE CCI THE DOCTOR FELT RESISTANCE. THE DOCTOR STOPPED AND REALIZED THE TORIC IOL WAS CRACKED IN HALF. THE FIRST PART OF THE IOL WAS ALREADY IN THE ANTERIOR CHAMBER (AC) WHILE THE SECOND HALF OF THE IOL WAS IN THE INJECTOR NOZZLE. THE INSERTER WAS PULLED OUT OF THE CORNEAL INCISION, AND THE FIRST HALF OF THE IOL WAS RETRIEVED FROM THE ANTERIOR CHAMBER. AS THE DAMAGED IOL OPENED UP IN THE ANTERIOR CHAMBER IT LIGHTLY NICKED THE PATIENTS' ENDOTHELIUM, LEAVING A SMALL 2-MILLIMETER SCRATCH. THE BROKEN OPTIC AND SINGLE HAPTIC WERE REMOVED. A BACKUP IOL WAS IMPLANTED SUCCESSFULLY WITHOUT ADDITIONAL COMPLICATIONS. THE PATIENT IS DOING WELL. A PHOTOGRAPH OF THE DAMAGED LENS WAS PROVIDED. JOHNSON AND JOHNSON REQUESTED THE RETURN OF THE PRODUCT AND THE CUSTOMER BELIEVES THEY HAVE ALREADY RETURNED IT. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Corneal Abrasion

    MAUDE report 24948574 ↗
  • InjuryFeb 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE OCULAR DEXTER (RIGHT EYE). THE IOL WAS EXPLANTED DUE TO COMPLAINTS OF TORIC UNCORRECTED ASTIGMATISM, POST-SURGERY. BLURRED VISION WITH OCULAR IMBALANCE FROM UNCORRECTED ASTIGMATISM. FIRST OBSERVED DURING POST-OPERATIVE EXAMINATION. DIPLOPIA/POOR STEREOVISION. PREOP VISUAL ACUITY: 20/30-1. POST OP VISUAL ACUITY 20/30. 1 MONTH DELAY IN PROCEDURE. ADDITIONAL ATR CYL CORRECTION NEEDED. LENS EXCHANGE FOR HIGHER POWER TORIC REQUIRED. DIU300 IOL WAS REPLACED WITH A DIU375 13.0 DIOPTER IOL. THERE WERE NO COMPLICATIONS, NO SUTURE(S), NO INJURY, AND NO VITRECTOMY. PATIENT OUTCOME POST LENS EXCHANGE IS UNKNOWN. DIU300 IOL IS NOT AVAILABLE FOR RETURN AS IT WAS DISCARDED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Blurred Vision; Visual Impairment

    MAUDE report 16344254 ↗
  • MalfunctionJun 21, 2022Scratched Material; Scratched Material

    IT WAS REPORTED THAT SCRATCH WAS NOTED ON THE PRELOADED INTRAOCULAR LENS (IOL) NEAR HAPTICS AFTER THE LENS WAS INSERTED INTO PATIENT'S LEFT EYE. THE LENS WAS REMOVED DURING THE SAME PROCEDURE. ANOTHER JOHNSON & JOHNSON LENS OF SAME MODEL AND DIOPTER WAS USED AS THE REPLACEMENT. NO OTHER INTERVENTION WAS REQUIRED. THE PATIENT HAS FULLY RECOVERED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14763616 ↗

Other LENS, INTRAOCULAR, TORIC OPTICS devices

All LENS, INTRAOCULAR, TORIC OPTICS devices →