TECNIS IOL DIU300 (REF DIU300U150)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 15.0D CYL3.00 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474747623), received between Oct 12, 2023 and Dec 10, 2025 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Contamination1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Visual Impairment1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 10, 2025Contamination; Contamination

    IT WAS REPORTED THAT THE PRELOADED JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE PATIENT¿S LEFT EYE. HOWEVER, THE DOCTOR NOTICED A METALLIC DEBRIS ADHERED TO THE LENS. THE DEBRIS WOULD NOT IRRIGATE SO THE DOCTOR USED AN INSTRUMENT TO PICK IT OFF THE LENS. THE DEBRIS WAS DISCARDED AND WILL NOT BE RETURNED TO JNJ. THE IOL REMAINS IMPLANTED. THERE WAS NO PATIENT HARM AND NO COMPLICATIONS SUCH AS A CAPSULE TEAR, VITRECTOMY, INCISION ENLARGEMENT, OR SUTURES. THE PATIENT IS DOING WELL. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23774420 ↗
  • InjuryJun 5, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PRELOADED JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE PATIENT¿S LEFT EYE. POST-OPERATIVE COMPLICATIONS WERE NOTED, INCLUDING HYPEROPIA AT THE ONE-WEEK POST-OPERATIVE MARK (ON (B)(6) 2025), WITH AN UNCORRECTED VISUAL ACUITY OF 20/40+1 AND REPORTS OF BLURRY VISION. MANIFEST REFRACTION WAS MEASURED AT PLANO+1.00X106, ACHIEVING A CORRECTED VISUAL ACUITY OF 20/20, THOUGH IT WAS NOT DEEMED SATISFACTORY. TESTING WITH A +2.0 D CYLINDER TRIAL LENS AT 107 DEGREES PRODUCED AN OVER-REFRACTION OF -1.00+0.75X174, RESULTING IN A VISUAL ACUITY OF 20/20-, WITH A SLOW AND UNCLEAR ENDPOINT. THE INTENDED AXIS FOR THE TORIC LENS WAS 21 DEGREES, BUT THE ACHIEVED AXIS WAS SLIGHTLY MISALIGNED AT 17 DEGREES. DESPITE ACCURATE PRE-OPERATIVE MEASUREMENTS AND CALCULATIONS, THE PATIENT EXPERIENCED SIGNIFICANT POST-OPERATIVE REFRACTIVE ERROR, NECESSITATING CONSIDERATION OF A DIFFERENT MODEL AND DIOPTER, SUCH AS DIU150. THE PATIENT, WHO WAS PREVIOUSLY ABLE TO DRIVE, REPORTED AN INABILITY TO DRIVE AT NIGHT DUE TO ISSUES WITH VISION CLARITY, WHICH HAS BEEN DESCRIBED AS DEBILITATING. THE INTRAOCULAR LENS REMAINS IMPLANTED, WITH THE EXPLANTATION PLANNED BUT NOT YET

    Patient problems: Visual Impairment

    MAUDE report 22152218 ↗
  • MalfunctionOct 12, 2023Break; Break

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS OPENED, NOT USED. ADDITIONAL INFORMATION WAS RECEIVED, REPORTING THAT THERE WAS A TORN HAPTIC IN THE INJECTOR. THERE WAS NO PATIENT CONTACT. A NEW LENS WAS USED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17922509 ↗