Skip to content

TECNIS IOL DIU600 (REF DIU600U215)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC EYHANCE TOR II SMPLCTY 21.5D CYL6.00 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05050474750111), received between Aug 20, 2024 and Jan 3, 2025 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Visual Impairment2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT HAD A HYPEROPIC SURPRISE, SPECIFICALLY A +1.50 SPHERICAL EQUIVALENT IN THE LEFT EYE, ONE WEEK AFTER INTRAOCULAR LENS (IOL) IMPLANTATION. THE PATIENT THEN WAS SCHEDULED FOR AN EXPLANT ON (B)(6) 2024. EXPLANT WAS DONE AS SCHEDULED, THE DOCTOR USED IRIS HOOKS AND SUTURES, NO VITRECTOMY. IT WAS NOTED THAT THE PATIENT HAS A PREEXISTING CONDITION OF FLOPPY IRIS SYNDROME, HENCE THE IRIS HOOKS WERE USED. REPLACEMENT IOL WAS SAME MODEL BUT 3.5D POWER SIZE HIGHER AS THE ORIGINAL IOL. IT WAS UNKNOWN IF REPLACEMENT IOL HELPED ADDRESS THE VISUAL ISSUES OF THE PATIENT. NEVERTHELESS, THERE WAS NO INJURY, AND SURGERY WAS COMPLETED SUCCESSFULLY. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: Visual Impairment

    MAUDE report 21072400 ↗
  • InjuryAug 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCE REFRACTIVE ERRORS AFTER IMPLANT OF A PRELOADED INTRAOCULAR LENS (IOL). THE LENS WAS EXPLANTED. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: Visual Impairment

    MAUDE report 20003540 ↗

Other LENS, INTRAOCULAR, TORIC OPTICS devices

All LENS, INTRAOCULAR, TORIC OPTICS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page