TECNIS IOL DFR00V (REF DFR00VU095)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TECNIS SYNERGY SIMPLICITY 09.5D · Class 3 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05050474750463), received between May 17, 2024 and May 17, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Blurred Vision1
- Halo1
- Visual Disturbances1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 17, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE MULTIFOCAL INTRAOCULAR LENS(IOL) HAD SIGNIFICANT GLARE AND HALO CAME FROM A LIGHT SOURCE. THE PATIENT HAD TO CLOSE AND/OR SQUINT THEIR LEFT EYE TO SEE BETTER. IT WAS FIRST REPORTED TO THE SURGEON ON (B)(6) 2021, DURING A POST-OP VISIT, AND HE KEPT COMING BACK WITH THE SAME COMPLAINT. SYMPTOMS SIGNIFICANTLY INTERFERE WITH THE PATIENT¿S DAILY ACTIVITIES. LENS WAS REPLACED WITH ANOTHER COMPANY IOL. PRE-OP UNCORRECTED AND BEST CORRECTED VISUAL ACUITY WAS -0.75 +0.25 X180 20/40 UC 20/40 BC, AND POST-OP BEST CORRECTED VISUAL ACUITY WAS -1.75+0.50 X060 20/40. POST-PROCEDURE, THE PATIENT IS DOING WELL. THERE WAS NO INJURY, AND SURGICAL AND MEDICAL INTERVENTIONS WERE REQUIRED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Blurred Vision; Halo; Visual Disturbances
MAUDE report 19347542 ↗
Other Lens, multifocal intraocular devices
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular144 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular1 recall66 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular113 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular112 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular110 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular107 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular104 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular93 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.