TECNIS IOL DFR00V (REF DFR00VU110)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS SYNERGY SIMPLICITY 11.0D · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 05050474750494), received between Feb 17, 2022 and Dec 22, 2023 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 2 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available2
  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Scratched Material1

Patient problems

  • Halo2
  • No Clinical Signs, Symptoms or Conditions2
  • Unspecified Tissue Injury2
  • Visual Disturbances2
  • Visual Impairment2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 22, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    A MALE PATIENT REPORTED OF INTRAOCULAR LENS (IOL) EXPLANTS ON BOTH EYES (OU) DUE TO EXPERIENCING HALOS, GLARE AND PHYSICAL DISCOMFORT. PRIOR TO SURGERY, THE PATIENT HAD CATARACTS AND -600 VISION IN BOTH EYES. AFTER SURGERY THE PATIENT EXPERIENCED GLARES AND HALOS THAT IMPACTED HIS ABILITY TO DRIVE AND GO OUTSIDE. THE PATIENT STATED FOR NINE (9) MONTHS LIGHT MADE HIM CRY AND EVEN HAD TROUBLE WITH LIGHTS ON IN THE HOUSE. WHILE THE PATIENT HAD THE LENSES, HIS EYELIDS FELT LIKE MUSHY SPONGES AND WERE CONSTANTLY BLOODSHOT. THE PATIENT ATTRIBUTES THE ISSUE HE EXPERIENCED TO COATING AND THE DESIGN OF THE LENSES, COLLECTING TOO MUCH SUNLIGHT. THE PATIENT WAS TOLD HER WOULD SEE FROM "INFINITY TO 14 FEET" AND HE DID NOT WANT TO WEAR GLASSES ANYMORE AND TO BE ABLE TO READ THE PAPER. THE PATIENT SAW OTHER DOCTORS AND WAS ADVISED TO HAVE THEM REMOVED. THE LENSES WERE EXCHANGED, AND THE PATIENT HAS 20/20 VISION IN BOTH EYES WITH JOHNSON & JOHNSON MONOFOCAL REPLACEMENT LENSES. THE PATIENT STILL HAS TO WEAR GLASSES. A MONTH LATER 1.75 LEFT EYE, 2.0 RIGHT EYE. THE PATIENT IS DOING FINE WITH THE REPLACEMENT LENSES AND ONLY HAS SOME LEFTOVER CONDITIONS LIKE ITCHY EYES AND TEARS WHICH ARE DISSIPATING.

    Patient problems: Halo; Unspecified Tissue Injury; Visual Disturbances; Visual Impairment

    MAUDE report 18384368 ↗
  • InjuryDec 21, 2023Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available; Adverse Event Without Identified Device or Use Problem; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THE DFR00V MODEL INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE PATIENT¿S OCULAR SINISTER (LEFT EYE). IN A SECONDARY SURGICAL PROCEDURE, THE IOL WAS EXPLANTED DUE TO COMPLAINTS OF DYSPHOTOPSIA AND THE EXPLANTED IOL WAS REPLACED WITH A ZCB00 14.0 DIOPTER IOL FOR -1.75 TARGET. THERE WAS NO PATIENT INJURY. PATIENT OUTCOME POST-LENS EXCHANGE WAS REPORTED AS STABLE POST-OP WITH SYMPTOMS RESOLVED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Halo; Unspecified Tissue Injury; Visual Disturbances; Visual Impairment

    MAUDE report 18379566 ↗
  • MalfunctionNov 2, 2022Scratched Material; Scratched Material

    IT WAS REPORTED THAT UPON INJECTION OF THE INTRAOCULAR LENS (IOL) THERE WAS A SCRATCH THAT WAS MADE BY THE INJECTOR AS IT WAS PUSHING THE LENS INTO THE PATIENTS LEFT EYE. IT WAS CONFIRMED THAT THE LENS WAS FULLY INSERTED INTO THE PATIENTS EYE WHEN THE SCRATCH WAS NOTICED AND THAT THE TIP OF THE CARTRIDGE WAS NOT DAMAGED/BROKEN. THE LENS WAS CUT OUT AND REMOVED FROM THE EYE. A BACKUP LENS OF THE SAME MODEL AND DIOPTER WAS USED AS REPLACEMENT DURING THE SAME PROCEDURE. IT WAS INDICATED THAT BALANCED SALT SOLUTION (BSS) WAS USED. THE LENS WAS CONTINUALLY LUBRICATED UNTIL IT WAS HANDED TO THE SURGEON. THERE WERE NO SURGICAL INTERVENTIONS REQUIRED AND NO PATIENT INJURY REPORTED. THE PATIENT OUTCOME IS UNKNOWN DUE TO HAVING POST-OPERATIVE APPOINTMENTS WITH ANOTHER DOCTOR AND THE ACCOUNT HAS NOT RECEIVED POST-OPERATIVE NOTES ON THE PATIENT. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15713103 ↗
  • MalfunctionFeb 17, 2022Break; Break

    IT WAS REPORTED THAT THE INTRAOCULAR LENS (IOL) WAS BENDING/ FOLDING UP INSIDE THE PRELOADED CARTRIDGE. ONLY THE CARTRIDGE TIP MADE CONTACT WITH THE PATIENT'S LEFT EYE. THE PROCEDURE WAS COMPLETED USING ANOTHER LENS OF SAME MODEL AND DIOPTER. THE PATIENT HAS REPORTEDLY RECOVERED. THE ORIGINAL LENS WAS DISCARDED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13553175 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →