TECNIS IOL DFR00V (REF DFR00VU255)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TECNIS SYNERGY SIMPLICITY 25.5D · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 05050474750784), received between Nov 30, 2021 and Oct 17, 2024 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Break1

Patient problems

  • Halo2
  • No Clinical Signs, Symptoms or Conditions1
  • Visual Disturbances1
  • Visual Impairment1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 17, 2024Break; Break

    IT WAS REPORTED THAT THE HAPTIC OF PRELOADED INTRAOCULAR LENS (IOL) WAS TORN/BROKEN. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20476875 ↗
  • InjuryOct 26, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM A PATIENT'S RIGHT EYE IN A SECONDARY SURGICAL PROCEDURE DUE TO MULTIFOCAL REFRACTIVE SURPRISE. NO MEDICAL OR SURGICAL INTERVENTION WAS REPORTED. THE PATIENT HAS FULLY RECOVERED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Visual Impairment

    MAUDE report 15677649 ↗
  • InjuryFeb 10, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED DUE TO HALO AND GLARE. THAT AT 1-MONTH POST-OP EXAMINATION, THE PATIENT ENDED UP BOTH EYES (OU) 20/20 J1, BUT COULD NOT TOLERATE HALO/GLARE. THE LENS WAS REMOVED AND REPLACED WITH A NON-JOHNSON AND JOHNSON MONOFOCAL IOL. THE LENS WAS DISCARDED, AND NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Halo; Visual Disturbances

    MAUDE report 13503585 ↗
  • InjuryNov 30, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM A PATIENT'S LEFT EYE IN A SECONDARY SURGICAL PROCEDURE AS THE PATIENT COMPLAINED ABOUT HALOS AND WAS NOT ADAPTING AFTER SIX (6) WEEKS. THE PROCEDURE WAS SUCCESSFULLY COMPLETED USING A NON-JOHNSON & JOHNSON (J&J) LENS AS A REPLACEMENT. THERE WAS NO DAMAGE TO THE CAPSULE OR ANY COMPLICATIONS DURING THE SURGERY AND NO MEDICAL OR SURGICAL INTERVENTIONS WERE REQUIRED. THE EXPLANTED LENS WAS DISCARDED. IT WAS INDICATED THAT THIS WAS THE PATIENT¿S SECOND EYE AND THEY HAD A NON-J&J LENS IN THE FIRST EYE. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Halo

    MAUDE report 12905937 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →