TECNIS IOL DXW150 (REF DXW150U195)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC SYMF TOR II OB SMPCY 19.5 CYL1.50 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05050474762961), received between Apr 8, 2024 and Apr 8, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Dry Eye(s)1
  • Halo1
  • Visual Disturbances1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A DOCTOR REPORTED THAT A PATIENT HAD UNCOMPLICATED FEMTO CATARACT SURGERY WITH IMPLANTATION OF THE INTRAOCULAR LENS (IOL) AND AN UNEVENTFUL POST OPERATIVE COURSE. NO HISTORY OF PRIOR EYE SURGERY OR REFRACTIVE SURGERY. PLANNED EXPLANT REPORTED AS THE PATIENT COMPLAINED OF PERSISTENT GLARE/HALOS. THE DOCTOR NOTED THAT THE IOL APPEARS WELL CENTERED AND IS ALIGNED ACCORDING TO THE INTENDED AXIS AS PER THE CAPSULAR MARKS MADE BY THE LASER. EVEN WITH REPEATED REFRACTIONS AND DRY EYE TREATMENTS, THE PATIENT REPORTS HIS VISION DOES NOT IMPROVE (COMPLAINED OF CONSTANT GLARE). IT WAS INDICATED THAT THE PATIENT WAS NOT DEBILITATED. THROUGH FOLLOW UPS, IT WAS LEARNED THAT THE LENS WAS EXPLANTED FROM PATIENT¿S LEFT EYE ON (B)(6) 2024. THE REPLACEMENT LENS USED WAS ANOTHER TORIC LENS OF A DIFFERENT MODEL (ZCU). NO CAPSULE TEAR, NO VITRECTOMY, NO COMPLICATIONS AND NO PATIENT INJURY REPORTED. NO MEDICATION OUTSIDE THE STANDARD OF CARE WAS REQUIRED. SO FAR, THE PATIENT IS STILL HEALING AND HAS MILD RESIDUAL CORNEAL EDEMA AND DRY EYE. BUT HE DOES HAVE MOMENTS OF CLEAR VISION AND REPORTS THAT THE PREVIOUS SYMPTOMS OF GLARE/HALO AND "BLURRY" VISION AT ALL DISTANCES ARE GONE. NO FURTHER INFORMATION WAS

    Patient problems: Dry Eye(s); Halo; Visual Disturbances

    MAUDE report 19068526 ↗