TECNIS IOL DXW150 (REF DXW150U210)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC SYMF TOR II OB SMPCY 21.0 CYL1.50 · Class 3 · Implant

All models of TECNIS IOL (1344)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474762992), received between Jun 5, 2023 and May 12, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Break1
  • Component Missing1
  • Ejection Problem1

Patient problems

  • Blurred Vision2
  • No Clinical Signs, Symptoms or Conditions1
  • Visual Disturbances1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S LEFT EYE AS THE PATIENT COMPLAINED OF BLURRY VISION AND THEY CLAIM THE LENS CONTRIBUTED TO THE VISUAL ISSUE. THERE WAS -0.9 D MYOPIC MISS. THE ISSUE WAS FIRST NOTICED DURING POST-OP EXAMINATION. THERE WERE NO DEBILITATING CONDITIONS AND THE SYMPTOMS DID NOT SIGNIFICANTLY INTERFERE WITH DAILY ACTIVITIES. THE LENS WAS EXPLANTED IN A SECONDARY PROCEDURE AND REPLACED WITH A SAME MODEL LENS WITH 20.0 DIOPTER. THE PATIENT FEELS BETTER WITH THE REPLACED LENS. THE BEST CORRECTED VISUAL ACUITY PRE-OP WAS 20/25 AND THE BEST CORRECTED VISUAL ACUITY POST-OP WAS 20/25. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: Blurred Vision

    MAUDE report 22007102 ↗
  • MalfunctionJan 11, 2024Break; Component Missing; Ejection Problem; Break; Component Missing; Ejection Problem

    IT WAS REPORTED THAT THE PRELOADED TORIC INTRAOCULAR LENS (IOL) WAS OPENED DURING SURGERY AND WAS FOUND TO BE DEFECTIVE, AS THE INJECTOR WENT ABOVE THE LENS INSTEAD OF PROGRESSING THE LENS. THROUGH FOLLOW-UP, IT WAS LEARNED THAT THE CARTRIDGE TIP WAS INSERTED INTO THE EYE WOUND AND THE LENS WOULD NOT ADVANCE. WHEN THE SURGEON SAW THIS, IT WAS ALSO NOTICED THAT THE LENS WAS CRACKED IN SEVERAL PLACES, SO THE SURGEON WITHDREW THE CARTRIDGE FROM THE EYE. THERE WAS NO PATIENT INJURY; THE SURGEON WITHDREW THE CARTRIDGE TO PREVENT INJURY TO THE PATIENT¿S EYE. NO MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. THROUGH ADDITIONAL FOLLOW-UP, IT WAS LEARNED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING A BACK-UP LENS (SAME MODEL AND SAME DIOPTER) FOR THE LEFT EYE. THERE WERE NO COMPLICATIONS AND THE PATIENT IS STABLE. IT WAS REPORTED THAT NO CARTRIDGE LUBRICATION WAS USED. THE DWELL TIME WAS 3 MINUTES OR LESS. WHEN ADVANCING THE LENS THE SCRUB TECHNICIAN MADE SMALL 1/4 TWISTS. IT WAS NOTED FROM THE SCRUB TECHNICIANS WHO WERE IN THE SURGERY THAT "THERE WERE NO PRINTED INSTRUCTIONS ON PROPER PROCEDURES FOR LOADING AND FILLING THE CHAMBER OF THE CARTRIDGE, NOR WHAT TO FILL THE CHAMBER OF TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18495431 ↗
  • InjuryJun 5, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE RIGHT EYE IN A SECONDARY PROCEDURE DUE TO THE PATIENT HAVING POOR VISION AND VISUAL DISTURBANCES/DYSPHOTOPSIA POST SURGERY AND WANTED AN IOL EXCHANGE. THE PATIENT'S PRE IOL EXCHANGE VISUAL ACUITY (VA) WAS 20/40+1 DISTANCE UNCORRECTED AND BEST CORRECTED 20/25+2 WITH -0.50+0.50X097 MANIFEST REFRACTION, AND J3 @ 19¿ FOR NEAR. THE VA WAS VERY BLURRY PER PATIENT. THE PATIENT HAS ANGLE KAPPA FROM ITRACE ASSESSMENT THAT INDICATES INTOLERANCE FOR EXTENDED DEPTH OF FOCUS (EDOF)/DEFRACTIVE IOLS. A NON-JOHNSON AND JOHNSON LIGHT ADJUSTABLE LENS WAS IMPLANTED AS REPLACEMENT (+20.0 DIOPTER). THERE WAS NO PATIENT INJURY REPORTED. NO MEDICAL OR SURGICAL INTERVENTION WAS REQUIRED. GOOD OUTCOME POST IOL EXCHANGE AND THE PATIENT IS HAPPY. THE PATIENT'S POST-OPERATIVE VA (POST-REPLACEMENT LENS) ON (B)(6) 2023 AT THE POST-OPERATIVE FOLLOW UP VISIT WAS 20/20 WITHOUT CORRECTION, AND 20/20 BEST CORRECTED. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Blurred Vision; Visual Disturbances

    MAUDE report 17066414 ↗