TECNIS IOL DXW150 (REF DXW150U215)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TEC SYMF TOR II OB SMPCY 21.5 CYL1.50 · Class 3 · Implant
All models of TECNIS IOL (1344)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05050474763005), received between Oct 6, 2023 and Jul 31, 2026 — classified as 3 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Device Dislodged or Dislocated1
Patient problems
- Blurred Vision1
- Capsular Contracture1
- Discomfort1
- Halo1
- Uveitis1
- Visual Disturbances1
- Visual Impairment1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJul 31, 2026Device Dislodged or Dislocated
It was initially reported that following implantation of a preloaded multifocal intraocular lens (IOL), model DXW150, the patient experienced halos, and a postoperative flipped axis was observed. Due to these symptoms, the implanted lens was explanted during a secondary surgical procedure and replaced with a ZCB00 21.5 D IOL (SN (b)(6)).Additional follow-up information indicated that the patient was a glaucoma suspect in both eyes (OU) and had previously undergone cataract surgery with implantation of a toric extended depth of focus (EDOF) IOL and a Kahook Dual Blade (KDB) procedure in the left eye (OS). The postoperative course was complicated by significant visual distortions and UGH (Uveitis-Glaucoma-Hyphema) syndrome in the left eye, which necessitated an IOL exchange procedure.Intraoperative findings during the lens exchange revealed that the toric IOL was positioned at the 108-degree meridian, with the trailing haptic located in the sulcus. Fibrosis of the inferior capsule was also noted. The patient's ocular history was significant for dry eye syndrome and myopia. The patient's medical history included insomnia, depression, and attention-deficit/hyperactivity disorder (ADHD)
Patient problems: Capsular Contracture; Halo; Uveitis; Visual Disturbances; Visual Impairment
MAUDE report 50100788 ↗InjuryMar 27, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PRELOADED JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE PATIENT¿S LEFT EYE. THE PATIENT WAS NOT ABLE TO HANDLE THE MULTIFOCALITY OF THE IOL. THE PATIENT WAS UNABLE TO SEE CLEARLY, NOT HAPPY WITH THEIR VISION. THE PATIENT STATED, ¿SOMETHING IS WRONG WITH MY VISION¿. THE EXPLANTED IOL WAS REPLACED WITH A BAUSCH AND LOMB LENS, MODEL 21.5 LI61A0. THE PATIENT WAS NOT INJURED AND THERE WAS NO MEDICAL INTERVENTION OR COMPLICATIONS SUCH AS A CAPSULE TEAR, VITRECTOMY, INCISION ENLARGEMENT, OR SUTURES. THE PATIENT WAS REPORTED AS DOING WELL SO FAR. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Blurred Vision
MAUDE report 21713497 ↗InjuryOct 6, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT AN INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM THE PATIENT'S LEFT EYE, DUE TO PATIENT NOT PLEASED WITH THE OUTCOME. THERE WAS NO INCISION ENLARGEMENT, NO VITRECTOMY, NO SUTURES PERFORMED. REPLACEMENT IOL WAS A ZCU150, 21.5D POWER SIZE. THE PATIENT OUTCOME REPORTED AS GOOD POST OPERATIVE APPEARANCE, STABLE. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Discomfort
MAUDE report 17892454 ↗
Other intraocular lens devices
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens146 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens145 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens144 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens139 reports
- TECNIS SIMPLICITY DIB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens1 recall81 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens129 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens127 reports
- TECNIS IOL PCB00Johnson & Johnson Surgical Vision, Inc. · intraocular lens126 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026