Skip to content

TECNIS ODYSSEY TORIC II IOL DRT150 (REF DRT1500190)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC ODYSSEY TOR II SMPCY 19.0D CYL1.50 · Class 3 · Implant

All models of TECNIS ODYSSEY TORIC II IOL (106)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05050474811331), received between May 12, 2025 and Feb 13, 2026 — classified as 4 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 2 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Break3
  • Crack2
  • Mechanical Jam1

Patient problems

  • Blurred Vision3
  • Halo2
  • No Clinical Signs, Symptoms or Conditions2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Capsular Bag Tear1
  • Eye Pain1
  • Toxic Anterior Segment Syndrome (TASS)1
  • Vitreous Loss1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 13, 2026Break; Crack

    IT WAS REPORTED THAT THE INJECTOR ON THE PRELOADED JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) SPLIT UPON INSERTION OF THE LENS RESULTING IN THE IOL BEING FRACTURED. THE FRACTURED ON THE LENS OCCURRED PRIOR TO INSERTING INTO THE EYE. CONSEQUENTLY, THE IOL WAS REMOVED WITH NO HARM TO THE PATIENT. JOHNSON AND JOHNSON PERFORMED FOLLOW-UP TO GET ADDITIONAL DETAILS, BUT A RESPONSE HAS NOT BEEN RECEIVED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24340173 ↗
  • MalfunctionFeb 13, 2026Break; Crack

    IT WAS REPORTED THAT THE INJECTOR ON THE PRELOADED JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) SPLIT UPON INSERTION OF THE LENS RESULTING IN THE IOL BEING FRACTURED. THE FRACTURED ON THE LENS OCCURRED PRIOR TO INSERTING INTO THE EYE. CONSEQUENTLY, THE IOL WAS REMOVED WITH NO HARM TO THE PATIENT. JOHNSON AND JOHNSON PERFORMED FOLLOW-UP TO GET ADDITIONAL DETAILS, BUT A RESPONSE HAS NOT BEEN RECEIVED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24340162 ↗
  • InjuryOct 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE JOHNSON AND JOHNSON (JNJ) INTRAOCULAR LENS (IOL) WAS IMPLANTED INTO THE PATIENT¿S LEFT EYE. THE PATIENT EXPERIENCED TOXIC ANTERIOR SEGMENT SYNDROME (TASS). THE ISSUE WAS IDENTIFIED DURING THE FOLLOW-UP EXAMINATION. THE IOL REMAINS IMPLANTED, AND THE DOCTOR HAS NO PLANS TO REMOVE IT. THERE WAS NO UNPLANNED INCISION ENLARGEMENT AND NO SUTURES. IT IS UNKNOWN IF THERE WAS AN UNPLANNED VITRECTOMY. THE DIRECTIONS FOR USE WERE FOLLOWED. THE PATIENT¿S POST-OPERATIVE VISUAL ACUITY OUTCOME IS UNKNOWN. REPORTEDLY, NO OTHER PATIENTS RECEIVED THIS LENS, AND NO OTHER ISSUES WERE REPORTED IN THE OPERATING ROOM. THE PATIENT STATES THAT THE EYE IS SORE AND PAINFUL. VISION IS BAD. THE PATIENT¿S VISUAL OUTCOME WAS REPORTED AS ¿CURRENTLY BEING TREATED.¿ THE FOLLOWING TREATMENT WAS REQUIRED FOR TASS. TOPICAL, SYSTEMIC, AND INTRAOCULAR MEDICATION, NO SUBCONJUNCTIVAL. PRESCRIPTION AND OVER THE COUNTER MEDICATION WAS REQUIRED. THE CUSTOMER DID NOT INDICATE IF THE MEDICATION WAS REQUIRED TO PRECLUDE PERMANENT INJURY AND DOSAGES WERE NOT PROVIDED. NO CULTURE OR PCR (POLYMERASE CHAIN REACTION) WAS PERFORMED. THE CUSTOMER DID NOT OBSERVE A PATTERN IN THEIR CASES AND ON THE DAY OF SURG

    Patient problems: Blurred Vision; Eye Pain; Toxic Anterior Segment Syndrome (TASS)

    MAUDE report 23327912 ↗
  • InjuryAug 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT HAD COMPLAINTS OF BLURRY VISION, HALOS, AND HAD DIFFICULTY DRIVING AT NIGHT. THE PRELOADED LENS WAS EXPLANTED DURING A SECONDARY SURGERY AND REPLACED WITH THE SAME MODEL BUT WITH A LOWER DIOPTER CYLINDER POWER. THE PATIENT'S VISUAL ACUITY IS 20/25. THE PATIENT HAS FULLY RECOVERED. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Blurred Vision; Halo

    MAUDE report 22919517 ↗
  • InjuryJul 2, 2025Break; Mechanical Jam; Break; Mechanical Jam

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS IMPLANTED, BUT VITREOUS ENTERED THE ANTERIOR CHAMBER, CAUSING THE IOL NOT TO SIT PROPERLY. THE IOL WAS PLACED AND THEN REMOVED DURING THE SAME PROCEDURE. THE PROCEDURE WAS COMPLETED WITH A IOL FROM ANOTHER MANUFACTURER. ADDITIONAL INFORMATION REVEALED THAT THE LENS DIDN¿T SEEM NORMAL AND WAS JAMMED IN THE CARTRIDGE. IT CAME OUT OF THE DEVICE DEFORMED AND UNUSABLE. THE PATIENT REQUIRED INCISION ENLARGEMENT AND AN UNPLANNED VITRECTOMY DUE TO A POSTERIOR CAPSULE TEAR. THE PATIENT IS DOING WELL. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Capsular Bag Tear; Vitreous Loss

    MAUDE report 22387289 ↗
  • InjuryMay 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM PATIENT'S LEFT EYE AS THE PATIENT COMPLAINED OF VISION BEING VERY BLURRY AFTER 8 FEET. DAYTIME HALOS AROUND BRIGHT LIGHTS, AND HORRIBLE HALOS AT NIGHT. LENS WAS EXPLANTED IN A SECONDARY PROCEDURE AND REPLACED WITH A NON JNJ LENS IN SECONDARY PROCEDURE. THERE WAS NO PATIENT INJURY. THERE WERE NO MEDICAL/SURGICAL INTERVENTION REQUIRED. THE BEST CORRECTED VISUAL ACUITY PRE-OP WAS 20/25, AND BEST CORRECTED VISUAL ACUITY POST-OP WAS 20/20. NO OTHER INFORMATION IS AVAILABLE.

    Patient problems: Blurred Vision; Halo

    MAUDE report 22006967 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page