TECNIS ODYSSEY TORIC II IOL DRT150 (REF DRT1500240)Recalls & reported problems
Johnson & Johnson Surgical Vision, Inc. · TEC ODYSSEY TOR II SMPCY 24.0D CYL1.50 · Class 3 · Implant
All models of TECNIS ODYSSEY TORIC II IOL (106)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05050474811430), received between Jan 30, 2025 and Aug 19, 2026 — classified as 3 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Break1
- Scratched Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Blurred Vision1
- Visual Disturbances1
- Visual Impairment1
- Zonular Dehiscence1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 19, 2026Scratched Material
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50333946 ↗MalfunctionJan 13, 2026Break
IT WAS REPORTED BY THE CUSTOMER THAT A PRELOADED MULTIFOCAL INTRAOCULAR LENS (IOL), MODEL DRT150, WAS RIPPED DURING AN ATTEMPT TO INSERT THE LENS. THE LENS DID NOT COME INTO CONTACT WITH THE PATIENT. THE PROCEDURE WAS COMPLETED USING A BACKUP LENS. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24063489 ↗InjuryAug 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PRELOADED LENS WAS EXPLANTED DUE TO BLURRED, HAZY VISION WITH GLARE. UNCORRECTED, THE PATIENT HAD A VISUAL ACUITY OF 20/30 WITH J5 NEAR VISION. THE PATIENT EXPERIENCED MINIMAL IMPROVEMENT WITH REFRACTION. AN EXCHANGE WAS PERFORMED FOR THE DIB00 LENS, WHICH WAS PREFERRED. NO INJURY OR INTERVENTION WAS REQUIRED. THE PATIENT FULLY RECOVERED. NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Visual Disturbances
MAUDE report 22757074 ↗InjuryJun 27, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PRELOADED INTRAOCULAR LENS (IOL) WAS EXPLANTED FROM PATIENT EYE AS THE PATIENT EXPERIENCED HYPEROPIA AFTER ONE MONTH OF HAVING THE LENS +1.00 SP. THE PATIENT FIRST REPORTED BLURRY VISION IN THE LEFT EYE ON, STATING THERE WAS NO CLEAR FOCAL POINT, AND THAT +1.25 READERS HELPED FOCUS AT 10 FEET. THE PATIENT FELT NEED LENS EXCHANGE. THE PATIENT DID NOT SUSTAIN ANY INJURY, AND NO FURTHER MEDICAL OR SURGICAL INTERVENTIONS ARE ANTICIPATED. THE PATIENT'S PRE-OP UNCORRECTED AND BEST CORRECTED VISUAL ACUITY WAS 20/15 NV: 20/40 AND CC: 20/15 AND THE POST-OP UNCORRECTED AND BEST CORRECTED VISUAL ACUITY OS SC: 20/30-2 AND OS CC: 20/20. FROM ADDITIONAL INFORMATION IT WAS LEARNT THAT THE ISSUE WAS DUE TO CAPSULAR TRACTION AND LENS DESIGN. THE PATIENT WAS MORE DEPENDENT ON READERS TO SEE MORE CLEARLY UP CLOSE TO READ OR DO NEAR VISION ACTIVITIES. THE VISUAL ISSUE EXPERIENCED BY THE PATIENT WAS NEAR VISION LIMITATIONS. THERE WAS NO USE ERROR. THE PATIENT IS MUCH HAPPIER WITH EXCHANGE AS THERE IS MORE CLARITY AND CAN SEE BETTER UP CLOSE. THERE WAS NO PATIENT INJURY. ADEQUATE HEALING TIME WAS GIVEN TO PATIENT TO SEE IF THE PATIENT WOULD ADJUST AND TRIED OTC READERS. NO OTHER
Patient problems: Blurred Vision; Visual Impairment
MAUDE report 22351939 ↗InjuryJan 30, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT WAS NOT A GOOD CANDIDATE FOR ODYSSEY INTRAOCULAR LENS (IOL). PATIENT HAD OCULAR ISSUES NOT TOLD TO THE SURGEON. THE BAG WAS NOT STABLE ENOUGH. SECONDARY SURGICAL INTERVENTION WAS REQUIRED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Zonular Dehiscence
MAUDE report 21280259 ↗
Other Lens, multifocal intraocular devices
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular144 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular1 recall66 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular113 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular112 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular110 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular107 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular104 reports
- Clareon™ CNA0T0Alcon Laboratories, Inc. · Lens, multifocal intraocular93 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page