Skip to content

TECNIS ODYSSEY TORIC II IOL DRT225 (REF DRT2250280)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC ODYSSEY TOR II SMPCY 28.0D CYL2.25 · Class 3 · Implant

All models of TECNIS ODYSSEY TORIC II IOL (106)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05050474812109), received between Aug 11, 2026 and Aug 11, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Visual Disturbances1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 11, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient underwent bilateral implantation of preloaded multifocal intraocular lenses (IOLs), models DXW150 and DRT225. Following implantation, the patient experienced intolerance to the multifocal intraocular lenses. As a result, both lenses were explanted during secondary surgical procedures.The replacement lens for the patient's right eye was a different model with the same diopter power, DET300U285 (SN (b)(6)). The replacement lens for the patient's left eye was a different model with a 0.5 diopter difference, DET150U285 (SN (b)(6)). The patient reported difficulty reading medication labels, viewing her phone, and reading expiration dates on food packaging. No incision enlargement, sutures, vitrectomy, or procedure delays were reported. The patient's outcome status was reported as unknown.The patient's preoperative refraction prior to the original surgery was +2.75 -0.75 x 076 in the right eye and +2.25 -0.50 x 040 in the left eye, with a target postoperative refraction of plano in both eyes. The postoperative refraction was reported as +1.00 -1.50 x 100 in the right eye and plano -0.75 x 150 in the left eye. The Directions for Use (DFU) were followed, and

    Patient problems: Visual Disturbances

    MAUDE report 50203038 ↗

Other Lens, multifocal intraocular devices

All Lens, multifocal intraocular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page