TECNIS ODYSSEY TORIC II IOL DRT375 (REF DRT3750170)Recalls & reported problems

Johnson & Johnson Surgical Vision, Inc. · TEC ODYSSEY TOR II SMPCY 17.0D CYL3.75 · Class 3 · Implant

All models of TECNIS ODYSSEY TORIC II IOL (106)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05050474813069), received between Dec 12, 2025 and Dec 12, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Visual Impairment1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AFTER THE PRELOADED MULTIFOCAL TORIC INTRAOCULAR LENS (IOL) WAS IMPLANTED IN THE RIGHT EYE, THE PATIENT STILL NEEDED TO USE READING GLASSES FOR COMPUTER WORK, READING, AND PHONE USE. THE ISSUE WAS FIRST IDENTIFIED DURING A POST-OPERATIVE EXAMINATION. THE PATIENT'S PRE-OPERATIVE (PRE-OP) REFRACTION WAS 20/50-1 AND PRE-OP BEST SPECTACLE CORRECTED VISUAL ACUITY (BSCVA) WAS 20/25-2. THE PATIENT'S POST-OPERATIVE (POST-OP) REFRACTION FOR THE ORIGINAL LENS WAS 20/25-1 AND POST-OP BSCVA FOR THE ORIGINAL LENS WAS 20/25. THE INTENDED TARGET REFRACTION WAS +0.05. THE PATIENT DID NOT HAVE A LOSS OF 2 OR MORE LINES OF BSCVA. THE PATIENT WAS OVER CORRECTED. THE PATIENT DID NOT HAVE ANY PRE-EXISTING CONDITION THAT AFFECTED CALCULATION. THE LENS WAS SUBSEQUENTLY EXPLANTED DURING A SECONDARY SURGERY AND REPLACED WITH A NON-JOHNSON AND JOHNSON IOL (+17.5 DIOPTER). THERE WAS NO DELAY IN PROCEDURE. THE PROCEDURE DID NOT INVOLVE UNPLANNED INCISION ENLARGEMENT, SUTURES, OR VITRECTOMY. NO ADDITIONAL MEDICAL ATTENTION WAS NEEDED AND NO MEDICATION WAS PRESCRIBED THAT WAS OUTSIDE THE STANDARD OF CARE. THERE WAS NO PATIENT INJURY. THE PATIENT HAS FULLY RECOVERED. THE PATIENT'S POST-OPERA

    Patient problems: Visual Impairment

    MAUDE report 23794857 ↗