Biolox Delta Modular Head 40mm EXTRA LONG +8.0mm 12/14 Eurocone Taper 104.4015Recalls & reported problems
Corin Ltd · Trinity with XL Heads · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05055196926998), received between May 29, 2025 and Apr 16, 2026 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K130343); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Insufficient Device Problem Information1
Patient problems
- Joint Dislocation1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 16, 2026Adverse Event Without Identified Device or Use Problem
TRINITY REVISION (OPS USED IN PRIMARY) OF THE BIOLOX DELTA CERAMIC HEAD AFTER APPROXIMATELY 2 YEARS AND 6 MONTHS DUE TO DISLOCATION.
Patient problems: Joint Dislocation
MAUDE report 24902860 ↗InjuryMay 29, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
TRINITY REVISION OF THE SHELL, BIOLOX DELTA CERAMIC HEAD AND BIOLOX DELTA CERAMIC LINER AFTER APPROXIMATIVELY 12 YEARS DUE TO REPORTED EDGE LOADING OF THE CERAMIC LINER PLEASE NOTE: THE TRINITY BIOLOX DELTA CERAMIC LINER SUBJECT OF THIS REPORT IS NOT CLEARED FOR SALE OR DISTRIBUTION IN THE USA AND THIS EVENT OCCURRED OUTSIDE OF THE USA. A BIOLOX DELTA CERAMIC HEAD WAS ALSO REVISED, THIS DEVICE IS CLEARED FOR SALE /DISTRIBUTION IN THE USA.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22103400 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K130343. One submission often covers many models, so check the product and lot details in each record.
- Z-1291-2021 · Jan 25, 2021 · TerminatedCorin BIOLOX DELTA MOD HEAD 36mm EX LONG +8mm12/14 TAPER. Corin Trinity Acetabular System with Extra Long Heads/Trinity Biolox Delta Ceramic Head (Generic Name: Hip Prosthesis).
- Z-1290-2021 · Jan 25, 2021 · TerminatedCorin BIOLOX DELTA MOD HEAD 32mm EX LONG +7mm 12/14 TAPER. Corin Trinity Acetabular System with Extra Long Heads/Trinity Biolox Delta Ceramic Head (Generic Name: Hip Prosthesis).
Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page