OrthoSolutions 'System26' Bone Screws OS900030-NSRecalls & reported problems
Ortho Solutions Holdings Limited · K-WIRE FOR 4.0MM SCREW DRILL TIP THREADED TIP 1.6 X 150MM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05055662956030), received between Mar 10, 2020 and Mar 25, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
1 other recall cover devices cleared under the same FDA submission (K163489); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture1
- No Apparent Adverse Event1
Patient problems
- Foreign Body In Patient1
- No Code Available1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 25, 2021No Apparent Adverse Event; No Apparent Adverse Event
DURING AN ORIF ANKLE PROCEDURE, WHERE THE PATIENT REQUIRED TWO CANNULATED SCREWS BI-MALLEOLAR, IT WAS REPORTED THAT THE K-WIRE BROKE UPON INSERTION AND RETAINED IN THE PATIENT. THE REMNANT PORTION OF THE WIRE WAS DISCARDED BY THE HEALTHCARE FACILITY. THE SURGICAL PROCEDURE PROCEEDED SUCCESSFULLY, AND NO PATIENT INJURY WAS REPORTED. NO FURTHER COMPLICATIONS WHICH REQUIRED MEDICAL INTERVENTION WERE REPORTED.
Patient problems: Foreign Body In Patient
MAUDE report 11567192 ↗InjuryMar 10, 2020Fracture; Fracture
DURING A MIDFOOT FUSION PROCEDURE, IT WAS REPORTED THAT AFTER INSERTING THE 4MM HEADLESS SCREW UNDER POWER AND PERCUTANEOUSLY OVER THE K-WIRE, IT WAS FOUND THAT THE K-WIRE TIP HAD BROKEN IN THE SCREW AND THEREFORE RETAINED IN THE PATIENT. THE FRACTURED K-WIRE TIP WAS CONFIRMED TO HAVE BROKEN OFF VIA X-RAY. THE SURGICAL PROCEDURE PROCEEDED SUCCESSFULLY, AND NO PATIENT INJURY WAS REPORTED. NO FURTHER COMPLICATIONS WHICH REQUIRED MEDICAL INTERVENTION WERE REPORTED.
Patient problems: No Code Available
MAUDE report 9812646 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K163489. One submission often covers many models, so check the product and lot details in each record.
- Z-0967-2018 · Oct 10, 2017 · TerminatedSYSTEM 26. Part Numbers: OS900035-NS; OS900036-NS; OS900037-NS; OS900038-NS; OS900040-NS; OS900041-NS; OS900042-NS; OS900043-NS; OS900047-NS; OS900048-NS; OS900045-NS; OS900046-NS;
Other Pin, Fixation, Smooth devices
- RIGIDFIX 210133Medos International Sàrl · PIN, FIXATION, SMOOTH91 reports
- SMART TOE ST0A-16PStryker GmbH · PIN, FIXATION, SMOOTH1 recall5 reports
- SMART TOE ST0-19PStryker GmbH · PIN, FIXATION, SMOOTH1 recall2 reports
- Flower E-Kit, Advanced EWK 201Flower Orthopedics Corporation · Pin, Fixation, Smooth1 recall0 reports
- Brasseler USA 5007972M0Peter Brasseler Holdings, LLC · PIN, FIXATION, SMOOTH1 recall0 reports
- ARROW-LOK 1Arrowhead De LLC · Pin, Fixation, Smooth1 recall0 reports
- ARROW-LOK 1Arrowhead De LLC · Pin, Fixation, Smooth1 recall0 reports
- ARROW-LOK 1Arrowhead De LLC · Pin, Fixation, Smooth1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.