Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-24-111-63-12-A12-22Recalls & reported problems
Lombard Medical Limited · Aorflex AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715606431), received between Dec 13, 2017 and Dec 13, 2017 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Aneurysm1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 13, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
EVENT: RE-INTERVENTION FOR TYPE 2 ENDOLEAK, 1B ENDOLEAK (LEFT) AND TYPE 3B ENDOLEAK (DISTAL, POSTERIOR ASPECT OF THE BIFURCATED SEGMENT). ORIGINAL EVAR: (B)(6) 2016. TYPE 2 ENDOLEAK IDENTIFIED ON POST-OP SCAN. ONE MONTH POST-EVAR: (B)(6) 2016. CTA SCAN SHOWS SAC SIZE AT 47 X 45MM. BETWEEN 6 AND 14 MONTHS POST-EVAR: (B)(6) 2016 TO (B)(6) 2017. CTA SCANS SHOW SAC SIZE TO BE SIGNIFICANTLY ENLARGED AT 57 X 54MM. RE-INTERVENTION: (B)(6) 2017. TO TREAT ORIGINAL TYPE 2 ENDOLEAK, BUT PROCEDURE COMMENCED WITH THE VIEW THAT THE PATIENT MAY ALSO HAVE A TYPE 1B ENDOLEAK AT THE DISTAL END OF THE RIGHT LIMB OF THE STENT GRAFT. DURING RE-INTERVENTION: TYPE 1B ENDOLEAK WAS CONFIRMED FROM THE LEFT LIMB OF THE STENT GRAFT, AND A TYPE 3B ENDOLEAK WAS ALSO IDENTIFIED COMING FROM THE DISTAL, POSTERIOR ASPECT OF THE BIFURCATED SEGMENT OF THE STENT GRAFT. THE STENT GRAFT WAS COMPLETELY RELINED USING A COMBINATION OF COMPETITOR DEVICES. POST-DEPLOYMENT SCAN: ALL ENDOLEAKS RESOLVED. ONE MONTH POST-OP: (B)(6) 2017. FOLLOW-UP SCAN SHOWED NO EVIDENCE OF ENDOLEAK. HOWEVER, DELAYED IMAGES SHOWED FAINT, DIFFUSE TYPE 2 LUMBAR ENDOLEAK. MANUFACTURER AWARENESS OF THE EVENT WAS VIA DEVICE TRACKING SYSTEM.
Patient problems: Aneurysm
MAUDE report 7111919 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page