Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-24-111-80-12-A12-22Recalls & reported problems
Lombard Medical Limited · Aorflex AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715606493), received between Jan 22, 2016 and Jan 22, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Occlusion Within Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Occlusion Within Device1
Patient problems
- Aneurysm1
- Thrombosis1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 22, 2016Occlusion Within Device; Occlusion Within Device
ON (B)(6) AN URGENT PROCEDURE WAS PERFORMED WITH USE OF AORFIX STENT GRAFTS FOLLOWING THE IFU. AT THAT TIME, THE PROCEDURE WAS FINISHED WITHOUT PROBLEM.RIGHT LEG: GRAFT CONSTRICTED IN SIZE AND LEFT LEG OCCLUDED DUE TO THROMBOSIS STENT GRAFTS AND ALL DEVICES WERE PLACED APPROACHING FROM THE LEFT FEMORAL ARTERY FOR ABDOMINAL EVAR.ON (B)(6) A DEALER INFORMED MEDICO'S HIRATA OF THE OCCLUSIONS PROBLEM DUE TO THROMBOSIS.REGARDING THE LEFT LEG, THE OCCLUSION DUE TO THROMBOSIS WAS CONFIRMED FROM THE BIFURCATION OF THE MAIN BODY TO THE DISTAL PART OF THE EXTERNAL ILIAC ARTERY. REGARDING THE RIGHT LEG, APPROXIMATELY HALF OF THE GRAFT FROM THE CONTRA-LATERAL LEG WAS CONSTRICTED IN SIZE.BUT THE RING STENT ITSELF WAS FULLY EXPANDED.ADDITIONAL PROCEDURE: SURGICALLY, A THROMBECTOMY WAS CONDUCTED. AFTER THE CUTDOWN, ACT VALUE WAS MEASURED. WITH A UNIT OF 11,000 INTRAVENOUS INJECTION WAS CONDUCTED AND ACT VALUE SHOWED 237. ABOUT EVERY 30 MINUTES, ADDING IT WITH A UNIT OF 1500, AND FINALLY, THE ACT VALUE SHOWED 228 AFTER APPROXIMATELY ONE HOUR. THE PROCEDURE WAS FINISHED.ANATOMY: PROXIMAL NECK ANGULATION: 131 DEGREE. OUTSIDE THE IFU.PHYSICIAN'S COMMENT: IT IS DIFFICULT TO IDENTIFY A CAUSE OF
Patient problems: Aneurysm; Thrombosis
MAUDE report 5384759 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page